Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: VP7U11A0
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Switched Outlet Level Monitoring EC 10A or 15A 120V or 208V or 230V 1.4 - VP7U11A0

Vertiv VP7U11A0 Switched Outlet-Level Monitoring Rack PDUThe Vertiv VP7U11A0 is a 0U horizontal rack power distribution unit that combines switched ou…

$1,752.00 $1,201.99 SAVE $550
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Switched Outlet Level Monitoring EC 10A or 15A 120V or 208V or 230V 1.4 - VP7U11A0

$1,752.00
$1,201.99

Overview

SKU: VP7U11A0
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv VP7U11A0 Switched Outlet-Level Monitoring Rack PDU

The Vertiv VP7U11A0 is a 0U horizontal rack power distribution unit that combines switched outlet control with per-outlet current, power, and voltage monitoring in a single 1U-depth form factor. Designed for data centers and high-density server rooms where granular power visibility matters, it delivers per-outlet on/off switching alongside real-time monitoring over a hardened network stack — without the cost of a full intelligent PDU platform. If your team needs to remotely cycle a locked-up server or pinpoint which circuit is pulling unexpected load, the VP7U11A0 addresses both without requiring a site visit.

Overview

At its core, the VP7U11A0 bridges two capabilities that are often sold separately: outlet-level switching and outlet-level monitoring. With six C13 output receptacles fed from a single C14 input, it suits 1U to 4U server environments where you need selective power sequencing or remote reboot without a KVM. The 0U horizontal mounting keeps rack unit space free for compute, while the built-in LCD display gives local technicians at-a-glance readings without needing a laptop or SSH session. Vertiv's Geist-line rack PDUs are a standard in colocation and enterprise data centers — the VP7U11A0 sits in that same lineage with a compact footprint suited for edge and branch deployments.

Key Features

  • Switched Outlet Control (6×C13): Each of the six C13 receptacles can be individually switched on, off, or power-cycled remotely. That means a locked-up server can be rebooted from your NOC without dispatching a technician — meaningful when your nearest hand is 40 minutes away at a remote site.
  • Per-Outlet Current, Voltage, and Power Monitoring: The VP7U11A0 monitors current, voltage, and power at the outlet level, not just at the PDU inlet. You can see exactly which device is pulling how many watts, which is the fastest way to find overloaded circuits before a breaker trips or a UPS alarms.
  • Flexible Input: 10A or 15A, 100–240V, 50/60 Hz: Supports both 10A and 15A input configurations and auto-ranges across 100–240V at 50 or 60 Hz. Deploy the same SKU across North American 120V circuits, European 230V racks, or mixed 208V three-phase environments without maintaining separate inventory.
  • C14 Input Connector: The IEC C14 power plug connects directly to standard C13/C15 outlets on UPS units and rack PDUs upstream — no adapters needed in the vast majority of data center and comms room environments.
  • LCD Display: The front-panel LCD surfaces real-time load readings locally. Useful for commissioning and for on-site support staff who need to verify readings without logging into the management interface.
  • Hardened Network Protocol Suite: The single RJ-45 Ethernet port supports SNMP v1/v2c/v3, HTTPS, SSH, RADIUS, TACACS+, LDAP, Syslog, NTP, Modbus TCP, DHCP, and both IPv4 and IPv6. For security teams enforcing network access control, RADIUS and TACACS+ integration means PDU authentication can tie into your existing AAA infrastructure — not a shared local password.
  • SNMP v3 with Syslog and NTP: SNMP v3 provides encrypted, authenticated trap delivery to your NMS or DCIM platform. Syslog export covers audit logging requirements. NTP synchronization keeps all timestamps consistent across devices — important when correlating power events with server logs during incident review.
  • Modbus TCP: Building management systems and DCIM tools that speak Modbus TCP can pull meter data directly from the VP7U11A0 without requiring SNMP integration — useful in facilities that standardized on Modbus before SNMP was common in the power layer.
  • Dual Stack IPv4/IPv6: Native IPv6 support means the VP7U11A0 fits into modern network segments already transitioning to IPv6 addressing without NAT workarounds or legacy management VLANs.
  • Serial and USB Ports: The single serial port enables out-of-band management or console access when the network path is unavailable. The USB port supports local configuration or firmware update workflows.
  • 3-Meter Power Cord: The 3m (approximately 10 ft) integrated cable provides enough reach for most standard rack configurations without requiring a cable extension — reduces a potential failure point in the power path.

Integration and Compatibility

The VP7U11A0 integrates with data center power management platforms via SNMP v3 MIBs, and Modbus TCP polling makes it compatible with building automation and DCIM systems from vendors like Vertiv, Nlyte, Sunbird, and others that support standard Modbus register maps. LDAP and RADIUS/TACACS+ mean user access can be managed through Active Directory or Cisco ISE rather than local accounts — a requirement in regulated environments. The unit operates as a single-phase device, so phase-balance planning at the PDU level is not applicable; upstream distribution panels handle phase assignment. For deployments requiring three-phase outlet-level switching, a three-phase Vertiv Geist PDU from the same Vertiv PDU catalog is the appropriate path.

Pair the VP7U11A0 with a compatible UPS or rack infrastructure upstream and a managed PoE switch for the management network connection to complete a remotely serviceable power stack at edge and branch sites.

Frequently Asked Questions

Q: What type of outlets does the VP7U11A0 have, and what plugs into them?

A: The VP7U11A0 has six IEC C13 output receptacles. Standard IEC C14 plugs from servers, switches, and other 1U rack equipment connect directly. The unit's own input is a C14 coupler, which connects to C13 outputs on upstream UPS units or rack-level PDUs.

Q: Can I power-cycle individual outlets remotely on the VP7U11A0?

A: Yes. Each of the six C13 outlets is independently switched. You can turn individual outlets on, off, or trigger a power cycle remotely via the web interface, SNMP, or SSH — without affecting the other outlets on the unit.

Q: What network protocols does the VP7U11A0 support for management?

A: The VP7U11A0 supports SNMP v1/v2c/v3, HTTPS, SSH, LDAP, RADIUS, TACACS+, NTP, Syslog, DHCP, Modbus TCP, RSTP, SMTP, and dual-stack IPv4/IPv6 — covering most enterprise NMS, DCIM, and AAA integration requirements.

Q: What input voltages does the VP7U11A0 support?

A: It supports 100–240V AC input at 50 or 60 Hz, rated for 10A or 15A circuits. This covers North American 120V, European 230V, and data center 208V single-phase environments from the same SKU.

Q: Does the VP7U11A0 have a display for local readings?

A: Yes, it includes an LCD display that shows real-time load data locally — useful during commissioning or when on-site staff need to verify load without network access.

Q: Is the VP7U11A0 compatible with DCIM platforms?

A: The unit supports SNMP v3 and Modbus TCP, which are the two primary integration protocols used by DCIM platforms such as Vertiv's own tools, Sunbird dcTrack, and Nlyte. Specific platform certification should be verified with your DCIM vendor against Vertiv's current compatibility matrix.

Jerry Tildsen
Jerry Tildsen

The VP7U11A0 is the PDU I'd spec for a remote edge rack where you need outlet-level switched control but can't justify a full intelligent PDU platform. The combination of per-outlet switching across all six C13 receptacles and real-time current/voltage/power monitoring at each port gives you the operational visibility of a high-end unit in a compact 0U horizontal form factor — and the auto-ranging 100–240V input means you're ordering one SKU whether the site runs 120V or 208V.

Technical Highlights:

  • SNMP v3 + RADIUS/TACACS+: Encrypted, authenticated SNMP trap delivery combined with RADIUS or TACACS+ AAA integration means PDU access management slots into your existing network security infrastructure — no shared local passwords floating around at remote sites.
  • Modbus TCP alongside SNMP: Having both protocols on the same unit means facilities teams running BMS/SCADA on Modbus and IT teams running NMS on SNMP can both pull meter data independently without protocol translation middleware.
  • C14 input, C13 outputs, 3m cord: The IEC connector pairing is exactly what you'd expect downstream of a standard rack UPS, and the 3-meter integrated cord reaches most standard rack configurations without an extension — one fewer failure point in the power chain.

Deployment Considerations:

  • This is a single-phase unit — plan your upstream circuit accordingly. If your rack requires phase-balanced three-phase outlet switching, you'll need a three-phase Geist PDU instead; the VP7U11A0 won't fill that role.
  • With only six C13 outlets, this unit is sized for small-footprint racks or targeted equipment groups (e.g., a firewall stack or a subset of servers that need independent reboot capability). It's not the right fit for a fully-loaded 42U high-density compute rack needing 20+ receptacles.

The VP7U11A0 is the right call for edge deployments — branch offices, communications rooms, and remote IDF closets — where local hands are infrequent, and remote power cycling plus load visibility over a secure management network are the two operational capabilities that actually reduce truck rolls.

Specifications
PDU types: Monitored, Switched
Type: Single-phase
Rack capacity: 0U
Mounting: Horizontal
Product colour: Black
Display: LCD
AC outlets quantity: 6 AC outlet(s)
Power plug: C14 coupler
AC outlet types: C13 coupler
Serial ports quantity: 1
Ethernet LAN (RJ-45) ports: 1
USB ports quantity: 1
LED indicators: Yes
Cable length: 3 m
Monitoring: Current, Power, Voltage
Supported network protocols: DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Nominal input voltage: 100-240 V
AC input frequency: 50/60 Hz
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources