Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv VP6UU0A1 is a vertically mounted, outlet-level monitored power distribution unit built for high-density data center racks and critical infrastructure deployments where granular power visibility and residual current detection matter. At 11.0kW capacity across 24 outlets — a mix of C13 and C19 couplers — it handles both standard 1U/2U server loads and high-draw appliances from a single unit. What separates the VP6UU0A1 from basic metered PDUs is the integrated Type B residual current metering (RCM): it detects both AC and DC leakage current, which is a requirement in many European data centers and increasingly specified in North American facilities prioritizing personnel safety and equipment protection. The black vertical form factor is designed to mount in the rear vertical channel of standard 19-inch or 600mm open-frame and enclosed racks, keeping cable management clean and outlet access direct.
The VP6UU0A1 supports Modbus TCP alongside SNMP v3, which broadens DCIM and BMS integration beyond traditional IT tooling into building management and industrial control environments. LDAP, RADIUS, and TACACS+ authentication integration means user access can be centrally managed and audited through existing enterprise directory infrastructure — no local account sprawl. NTP synchronization ensures log timestamps align with syslog and SIEM event correlation. For facilities running Vertiv's broader infrastructure portfolio, this PDU fits directly into Vertiv's Intelligent Infrastructure management ecosystem. It can also be managed through any standards-based PDU management platform supporting SNMP or Modbus TCP. Organizations evaluating data center power infrastructure should review outlet-count requirements carefully — 24 outlets covers a mid-density rack, but high-density GPU or storage racks may require a higher-outlet-count model in the same family. For facilities requiring a UPS upstream, verify that the upstream UPS output matches the VP6UU0A1's 16A/11kW input ratings before commissioning.
Q: What is Type B residual current metering, and why does it matter for my rack?
A: Type B RCM detects AC, pulsating DC, and smooth DC leakage currents — the full range produced by modern switch-mode power supplies and variable-frequency drives. Type A detectors (the more common and cheaper alternative) miss smooth DC leakage entirely. If your rack includes servers with active PFC power supplies or mixed AC/DC architectures, Type B is the correct specification for personnel and equipment protection.
Q: How many outlets does the VP6UU0A1 provide, and what types?
A: The VP6UU0A1 provides 24 AC outlets in a mix of C13 and C19 IEC coupler types. C13 outlets handle standard 1U server and networking gear; C19 outlets accommodate high-draw devices up to 16A. The exact C13/C19 split should be confirmed against the full product datasheet for your specific configuration.
Q: Does the VP6UU0A1 support SNMP v3?
A: Yes. The VP6UU0A1 supports SNMP v1, v2c, and v3. SNMP v3 provides authenticated and encrypted polling, which is required in security-conscious management network environments. It also supports Modbus TCP for integration with DCIM and building management systems.
Q: Can the VP6UU0A1 integrate with LDAP or RADIUS for centralized authentication?
A: Yes. The VP6UU0A1 natively supports LDAP, RADIUS, and TACACS+ for user authentication, allowing access control to be managed through existing enterprise directory infrastructure rather than local device accounts.
Q: What are the physical dimensions and mounting orientation of the VP6UU0A1?
A: The VP6UU0A1 mounts vertically and measures 51mm wide × 66mm tall × 1829mm deep (approximately 72 inches in length), spanning a standard 42U rack in the vertical rear rail position. This preserves all horizontal U-space for equipment.
Q: Does the VP6UU0A1 support IPv6?
A: Yes. The VP6UU0A1 supports both IPv4 and IPv6 on its dual RJ-45 Ethernet management interfaces, making it compatible with facilities running IPv6-only or dual-stack management networks.

The detail I keep coming back to on the VP6UU0A1 is the Type B residual current metering — not because it sounds impressive on a spec sheet, but because I've seen facilities spec Type A and then discover post-installation that their GPU nodes and high-efficiency PSUs generate smooth DC leakage that Type A completely ignores. At 11.0kW and 16A max current, this PDU is sized for real production racks, and pairing that capacity with genuine Type B detection closes a safety gap that a lot of procurement teams don't catch until an auditor flags it.
Technical Highlights:
Deployment Considerations:
This PDU is a strong fit for colocation deployments, financial services data centers, and any facility running a formal power audit program — specifically where Type B RCM compliance is written into the facility standard or lease agreement. It's not the right call for simple power distribution where outlet-level telemetry isn't being consumed; in that scenario, a basic metered PDU will cost less and deliver what's actually needed.