Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: 28153VH
Condition: New
Write a Review 31% OFF

Vertiv Rpdu Basic Surge 20A 120V 1.9KW - 28153VH

Vertiv 28153VH Basic Surge Horizontal Rack PDUOverviewThe Vertiv 28153VH is a 0U horizontal basic PDU built for rackmounted environments that need str…

$350.00 $240.99 SAVE $109
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv Rpdu Basic Surge 20A 120V 1.9KW - 28153VH

$350.00
$240.99

Overview

SKU: 28153VH
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv 28153VH Basic Surge Horizontal Rack PDU

Overview

The Vertiv 28153VH is a 0U horizontal basic PDU built for rackmounted environments that need straightforward, reliable power distribution without the overhead of switched or monitored intelligence. Rated at 20A/120V with 10 NEMA 5-20R receptacles, it is sized for light-to-midrange IT equipment loads in server rooms, network closets, and security head-end racks. Its horizontal 0U form factor keeps it out of your equipment unit count while still fitting cleanly into standard 19-inch cabinets. For integrators populating racks with NVRs, switches, and access control panels, the rack PDU category is where the 28153VH lives — no per-outlet metering, no management overhead, just protected, distributed AC power.

Key Features

  • 10 NEMA 5-20R Outlets: Ten 20A-rated receptacles give you enough positions to fully populate a mixed rack of NVRs, PoE switches, and server appliances without a secondary PDU. The 5-20R blade pattern accepts both standard 5-15P and 5-20P plugs — practical in mixed-equipment environments where legacy gear and modern appliances share the same rack.
  • NEMA L5-20P Locking Input Plug: The twist-lock L5-20P input connector prevents accidental disconnection at the circuit — a meaningful detail in racks that get serviced under load. Pair this with a dedicated 20A branch circuit and you stay within the 80% NEC continuous-load rule at 16A draw.
  • 20A / 120V / 1.9 kW Capacity: A 20A input rated at 120V delivers up to 1.9 kW of available load — enough headroom for 8–10 midrange 1U devices simultaneously. The overcurrent protection feature guards connected equipment against branch-circuit faults, reducing the risk of cascading failures across the rack.
  • Surge Protection: Built-in surge suppression absorbs transient voltage spikes before they reach connected equipment. In security rack deployments where NVR storage drives and network switches are constantly powered, even a brief transient can corrupt drives or damage switching hardware — surge protection here is not optional.
  • 0U Horizontal Mounting: The zero-U horizontal form factor mounts in a standard rack without consuming any equipment rack units. That matters in fully populated 42U cabinets where every U is spoken for. The 3-meter (approximately 9.8 ft) input cord provides enough reach to connect to a floor-level PDU or wall outlet without cable management headaches.
  • Wide Operating Temperature Range (0–60°C): Rated from 0°C to 60°C, the 28153VH operates in warm equipment rooms and non-climate-controlled closets without derate concerns. Most rack environments stay well under 40°C; the 60°C ceiling means this unit won't be the limiting factor in a warm-room deployment.
  • 50/60 Hz Dual-Frequency Input: Accepts both 50 Hz and 60 Hz AC input, making it compatible with domestic 60 Hz facilities as well as international 50 Hz infrastructure if equipment is ever relocated or shipped to a 50 Hz site.
  • RoHS Compliant / UL & c-UL Listed: UL and c-UL listing confirms the unit has been independently tested to North American and Canadian safety standards — required by most enterprise and government facility managers before a PDU goes into a production rack. RoHS compliance satisfies EU hazardous-substance restrictions for international deployments or resale.

Integration and Compatibility

The 28153VH draws from a standard 20A/120V single-phase branch circuit — the most common circuit type in North American rack environments. The NEMA L5-20P input pairs directly with L5-20R receptacles found on UPS units from rack UPS systems in the same power tier, making this PDU a natural downstream load on an APC, Vertiv, or CyberPower 1500–3000VA tower or rackmount UPS. There is no network interface or management card, so integration with DCIM or power management software is not applicable; this is a purely passive distribution and protection device. If your deployment requires per-outlet switching, remote monitoring, or branch-circuit metering, step up to a monitored or switched PDU in the Vertiv lineup. For standard rack cabinet installations where you just need protected outlets at the right voltage and amperage, the 28153VH covers the job without unnecessary complexity.

Frequently Asked Questions

Q: What input plug does the Vertiv 28153VH use, and what circuit does it require?

A: The 28153VH uses a NEMA L5-20P twist-lock input plug. It requires a dedicated 20A, 120V single-phase branch circuit. Per NEC continuous-load rules, plan your connected load at no more than 16A (80% of 20A) for 24/7 operation.

Q: How many outlets does the 28153VH provide, and what receptacle type?

A: It provides 10 NEMA 5-20R receptacles. The 5-20R blade pattern accepts both NEMA 5-15P and 5-20P plugs, so standard 15A equipment cords plug in alongside 20A devices without adapters.

Q: Does the 28153VH take up rack unit space?

A: No. It is a 0U horizontal PDU that mounts in the rack without consuming any equipment rack units (U spaces), typically using the rack's mounting channels or side brackets.

Q: What kind of power protection does the 28153VH include?

A: It includes both overcurrent protection and surge suppression. Overcurrent protection guards against branch-circuit faults; surge suppression absorbs transient voltage spikes before they reach connected devices.

Q: Is the Vertiv 28153VH UL Listed?

A: Yes. The 28153VH carries UL and c-UL listing (UL 60950 standard), confirming it has been independently tested to North American and Canadian electrical safety requirements. It is also RoHS compliant.

Q: How long is the input power cord on the 28153VH?

A: The input cord is 3 meters (approximately 9.8 feet), providing enough reach for most rack-to-circuit connections without requiring an extension.

Jerry Tildsen
Jerry Tildsen

The 28153VH is one of those units I recommend when integrators ask me what to put on the power rail of a security head-end rack that doesn't need monitoring — the NEMA L5-20P twist-lock input is the spec that matters most here, because it means nobody accidentally kicks the cord loose during a service call at 2 AM. Ten NEMA 5-20R outlets at 20A/120V is the right profile for a mixed rack of NVRs, managed switches, and access control panels where you're rarely topping 12–14A combined draw.

Technical Highlights:

  • NEMA L5-20P Locking Input: Twist-lock connector eliminates accidental disconnection at the PDU input — a real operational safeguard in racks that are serviced under load or in tight spaces.
  • 10x NEMA 5-20R Receptacles: The 5-20R accepts both 5-15P and 5-20P plugs, so you're not buying adapters for legacy 15A devices. Ten positions is enough for a fully loaded 1U NVR, 2–3 PoE switches, and several auxiliary devices without a secondary strip.
  • 0°C to 60°C Operating Range: Designed to run in warm equipment rooms up to 60°C — that's a meaningful ceiling for non-conditioned closets where ambient can climb into the high 30s under load.

Deployment Considerations:

  • Size your branch circuit to 20A dedicated — the L5-20P input demands it, and sharing with other loads will put you over the 80% NEC continuous-load threshold at moderate rack density.
  • Watch out: this is a basic PDU with no remote monitoring, no per-outlet switching, and no network interface. If you need remote reboot capability or real-time current metering, this is the wrong model — step up to a Vertiv monitored or switched PDU in the same family.

The 28153VH belongs in any security integrator's rack BOM where the head-end cabinet is well-planned, the circuit is sized, and the operator doesn't need DCIM integration — specifically the mid-density NVR rack in a commercial building's IDF closet where simplicity and protected outlets are the whole requirement.

Specifications
PDU types: Basic
Type: Single-phase
Rack capacity: 0U
Mounting: Horizontal
Product colour: Black
On/off switch: No
AC outlets quantity: 10 AC outlet(s)
Power plug: NEMA L5-20P
AC outlet types: NEMA 5-20R
Cable length: 3 m
Nominal input voltage: 100-120 V
AC input frequency: 50/60 Hz
Maximum current: 20 A
Output voltage: 120 V
Load capacity: 120 VA
Power protection features: Over current
Certification: RoHS Compliant UL & c-UL Listed 60950
Operating temperature (T-T: 0 - 60 °C
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources