Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AP8958
UPC: 731304277101
Condition: New
Write a Review 35% OFF

APC by Schneider Electric Rack PDU 2G Switched Zerou 20A/208V 16A/230V (7) C13 & (1) C19 - AP8958

APC by Schneider Electric AP8958 Switched Rack PDU 2G Zero-UOverviewThe AP8958 is a 2nd-generation switched rack power distribution unit from APC by S…

$2,000.00 $1,302.99 SAVE $697
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Rack PDU 2G Switched Zerou 20A/208V 16A/230V (7) C13 & (1) C19 - AP8958

$2,000.00
$1,302.99

Overview

SKU: AP8958
UPC: 731304277101
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric AP8958 Switched Rack PDU 2G Zero-U

Overview

The AP8958 is a 2nd-generation switched rack power distribution unit from APC by Schneider Electric, designed for zero-rack-unit (Zero-U) vertical mounting inside standard 2-post or 4-post open racks and enclosed cabinets. With 20A/208V and 16A/230V input support and eight total receptacles — seven C13 and one C19 — the AP8958 gives data center and IT infrastructure teams per-outlet remote switching capability: power-cycle locked-up devices, sequence startup loads, and shed non-critical circuits without touching the physical hardware. The single C19 outlet handles higher-draw gear (UPS bypass, dual-PSU servers drawing full load on one leg) while the seven C13 ports cover standard 1U and 2U server PSUs, KVM switches, and network appliances. Output voltage flexibility across 100V, 200V, 208V, and 230V makes the AP8958 suitable for mixed North American and international rack deployments sharing common distribution infrastructure.

Compatibility

The AP8958 is designed for APC NetShelter SX, SX Open Frame, and AR-series enclosed cabinets, where Zero-U vertical PDU channels are built into the side rails. It is also compatible with any standard EIA-310 open-frame rack that provides a vertical PDU mounting channel or pass-through bracket. On the load side, C13 outlets accept standard IEC 60320 C14 power cords used by the majority of 1U–4U rack servers, Ethernet switches, patch panels with active components, and IP surveillance NVRs. The C19 outlet accepts C20 cords, common on higher-wattage rack servers, APC Smart-UPS RT units used as downstream conditioning, and high-density PoE switch PSUs. Network management integrates with APC EcoStruxure IT, PowerChute Network Shutdown, and SNMP/HTTP-based DCIM platforms through the onboard network management card interface.

Installation Notes

Zero-U mounting positions the AP8958 vertically along the inside rail of the cabinet, consuming no rack unit space — critical in fully populated 42U or 48U deployments where every horizontal unit counts. Confirm your cabinet's vertical PDU channel accepts the AP8958 form factor before ordering; NetShelter SX cabinets with factory vertical mounting channels are a confirmed fit. Input cord length and the location of your PDP or circuit breaker panel will determine whether an extension whip is needed — measure the run before commissioning. The 20A circuit breaker on the input side means this PDU must be fed from a dedicated 20A branch circuit; do not share the branch with other PDUs or high-inrush loads.

Specifications
Eccn: 5A992
Dimensions: 2.2000000000000002 in.
Color: Black
Output Voltage: 100V,200V,208V,230V
Rack Units: 0
Receptacle Configuration: 16
Number Of Outlets: 8
Type: RACK MOUNT PDU
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources