Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit LDPH5EI6-A Single Channel Power-Rated Surface Raceway

Overview

The Panduit LDPH5EI6-A is a Pan-Way® LDPH5 power-rated, two-piece latching surface raceway in Electric Ivory PVC — a go-to solution for routing low-voltage or mains-rated wiring neatly along perimeter walls, baseboards, and ceilings in commercial and institutional environments. Rated for circuits up to 600 V and UL5A Listed, this 6-foot section handles both data and power cabling in a single channel, eliminating the patchwork of exposed wire clips or split-loom that plagues retrofit AV, camera, and network cable runs. If you're managing wire routing and cable management in a school, hospital, or office environment, the LDPH5EI6-A (often searched as LDPH5EI6 A) is engineered to meet the finish and compliance standards those environments demand.

Key Features

  • 600 V Power Rating with UL5A Listing: Unlike low-voltage-only raceways, the LDPH5 series is approved for power circuits up to 600 V — meaning a single run can carry both your PoE camera feed and an adjacent 120 V power drop without requiring a separate conduit. UL5A listing means it satisfies NEC and building inspection requirements without debate on the job site.
  • Two-Piece Latching Design: The hinged, snap-together cover lets you lay cables in after mounting the base, rather than threading them through — a real time saver when retrofitting an existing wall run or adding cables post-install. No tools needed to open or close the cover during future adds or changes.
  • 1.02 × 0.55 in (26 × 14 mm) Cross-Section: The interior dimensions give you enough fill capacity for a typical camera homerun — Cat6 plus a power conductor — without the visual bulk of a larger wireway. The compact 0.55 in depth keeps the profile low against the wall, which matters in finished spaces where aesthetics are a client requirement.
  • Factory-Applied Adhesive Backing: The base ships with adhesive pre-applied, so you can mount directly to smooth, clean walls without drilling in most retrofit scenarios. Combined with the pre-punched mounting holes (for screw-down permanence where needed), this gives you flexibility on whether you anchor mechanically or adhesively — or both — depending on wall substrate.
  • PVC Construction, UL94V-0 / FT4 Flame Rating: UL94V-0 self-extinguishing PVC means the raceway will not sustain a flame — a code requirement in many commercial occupancies. FT4 flame spread compliance (per CSA) extends its applicability into Canadian projects without sourcing a separate product.
  • Meets TIA/EIA Standards: TIA/EIA compliance confirms the raceway won't degrade signal performance for structured cabling runs — relevant when you're routing Cat6 alongside copper for access control or IP camera systems where link quality matters.
  • Electric Ivory Color: Matches standard off-white wall and ceiling finishes common in healthcare, education, and office interiors — reducing the need for paint touch-ups or color coordination on finished-space installations.
  • Compatible with Pan-Way Surface Mount Outlet Solutions: Terminates directly into Panduit Mini-Com Surface Mount Boxes and surface mount outlet box solutions, so your cable run ends cleanly at a finished outlet rather than with a wire stub. This is the detail that separates a professional-looking installation from a field-rigged one.
  • Sold in 6-Foot Sections (Package Qty: 6): Each package contains 6 sections — 36 linear feet per box — with a carton quantity of 120 sections (720 ft) for large projects. Plan your run length in 6-ft increments; sections butt together and couplers (sold separately) maintain a clean joint.

Integration & Compatibility

The LDPH5EI6-A integrates with the broader Panduit Pan-Way surface raceway ecosystem, including elbows, tees, couplers, inside/outside corners, and entrance end fittings — all matched to the LDPH5 channel profile. The LDPH fitting family is called out explicitly in the product data as the correct accessory set for this raceway body. For structured cabling termination, Panduit Mini-Com Surface Mount Boxes drop in at the end of the run for a code-compliant, finished outlet. This raceway is well suited to IP security camera cable runs and access control homerun wiring in retrofitted commercial spaces where in-wall routing is not an option. For planning multi-run installations, pair with a cable management strategy that accounts for bend radius at corners — the two-piece latch design accommodates field-cut mitered corners with standard fitting accessories. The competitor cross-reference V2800 is noted in manufacturer data for integrators sourcing against legacy BOMs.

What's in the Box

  • 6x Panduit LDPH5EI6-A Pan-Way Surface Raceway sections (6 ft each, Electric Ivory PVC)

Frequently Asked Questions

Q: Is the LDPH5EI6-A rated for power wiring, or is it low-voltage only?

A: The LDPH5EI6-A is power rated for circuits up to 600 V, and it is UL5A Listed — making it suitable for both power and low-voltage cable runs in the same channel where code permits combined routing.

Q: Does the LDPH5EI6-A include adhesive mounting, or do I need to drill?

A: The base comes with factory-applied adhesive backing for mounting to smooth, clean surfaces. It also includes pre-punched mounting holes if you prefer or require mechanical fastening — you can use either method or combine them.

Q: What are the exact interior dimensions of the LDPH5EI6-A channel?

A: The channel is 1.02 inches wide by 0.55 inches deep (26 mm × 14 mm). This cross-section accommodates a typical camera or access control homerun — Cat6 plus a power conductor — in a low-profile form factor.

Q: How many sections come in a package, and what is the total run length per box?

A: Each package contains 6 sections at 6 feet each, providing 36 linear feet per package. The full carton contains 120 sections (720 linear feet) for larger project orders.

Q: What fitting accessories are compatible with the LDPH5EI6-A for corners and terminations?

A: The LDPH5EI6-A is designed for use with the LDPH fitting family, which includes elbows, couplers, and corner fittings matched to this channel profile. For outlet terminations, it is compatible with Panduit Mini-Com Surface Mount Boxes and surface mount outlet box solutions.

Q: Does the LDPH5EI6-A meet flame spread requirements for commercial installations?

A: Yes. The PVC construction carries UL94V-0 self-extinguishing and FT4 flame spread ratings, satisfying commercial building code requirements in both US and Canadian projects.

Jerry Tildsen
Jerry Tildsen

The LDPH5EI6-A is a detail product that gets underspecified on bids — integrators will quote generic raceway and end up with a piece that either fails inspection (no UL5A listing) or can't carry the 120 V homerun they need alongside the Cat6. The 600 V rating on this channel matters when the scope includes both PoE camera cable and a branch circuit in the same surface run, which is common in healthcare and school retrofits where in-wall routing isn't an option.

Technical Highlights:

  • 600 V / UL5A Rated: Permits combined power and data routing in a single channel — avoids the cost and visual clutter of running separate EMT conduit for the power leg alongside a low-voltage raceway.
  • 1.02 × 0.55 in Channel (26 × 14 mm): Sized for a standard camera homerun (Cat6 + 18 AWG power pair) with reasonable fill margin. Tight enough to stay visually minimal on finished walls; not a solution for high-density bundle runs — plan accordingly.
  • Factory Adhesive + Pre-Punched Holes: Dual mounting method gives you flexibility on substrate — adhesive alone on drywall or painted CMU; add screw anchors on high-traffic or high-vibration runs without sourcing a separate mounting kit.

Deployment Considerations:

  • Sections are 6 ft each — plan your run length to minimize field cuts, and order fittings from the LDPH family (elbows, couplers, inside/outside corners) at the same time. These are not universal-fit; the LDPH5 profile requires LDPH-matched accessories.
  • The 1.02 in wide channel is not a high-fill wireway. If your camera run includes more than two conductors or you're pulling trunk cable, step up to a wider Pan-Way channel. Overfilling a 26 mm channel will make the latch difficult to close and may create cable stress at bend points.

This is the right spec for hospital corridor camera retrofits, classroom perimeter cable management, and office access control homerun runs where aesthetics, code compliance, and dual power/data routing need to coexist in a single surface-mounted solution.

Specifications
Mount Type: Wall; Ceiling
Sub Brand: Pan-Way®
Color: Electric Ivory
Material: PVC
Height In: 0.55
Height Mm: 14
Length Ft: 6
Length M: 1.8
Width In: 1.02
Width Mm: 26
Product Type: Single Channel Surface Raceway
Carton Qty: 120
Package Qty: 6
Standards: UL94V-0, FT4, Meets TIA/EIA Standards, UL5A Listed, UL Compliant
Upc: 07498334423
Cable Category: wire-routing-management-protection
Type: Single Channel Surface Raceway
Q&A
Reviews
Have Questions?

Panduit Race WAY PWR EI 1.02X0.55 IN 6FT.

$24.48
$15.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources