Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv PBRGXT5X-288VBAT PRO Refresh Plus Multi GXT5 288V Battery Service Plan

Overview

The Vertiv PBRGXT5X-288VBAT is a two-year PRO Refresh Plus service contract covering the external 288V battery cabinets paired with Liebert® GXT5 UPS systems — specifically the GXT5-8000MVRT6UXLN and GXT5-10KMVRT6UXLN models. For facilities running high-density rack power in data centers, comms rooms, or critical security infrastructure, battery cabinet serviceability is a tier-one concern: a degraded battery bank that no one catches until a power event defeats the purpose of the UPS entirely. This plan closes that gap by delivering proactive, scheduled battery health management under a single agreement.

The GXT5 platform's built-in intelligence feeds directly into this service offering. The Liebert® GXT5 continuously monitors battery health and generates replacement date predictions — meaning service visits are planned around real battery condition data, not calendar guesswork. That's the distinction between reactive break-fix and genuine lifecycle management for a 288V multi-cabinet topology.

Key Features

  • Intelligent Battery Health Prediction: The Liebert® GXT5 provides battery health status and replacement date prediction, so technicians arriving on-site have data-driven guidance rather than performing exploratory diagnostics. On a 288V extended-runtime cabinet configuration, this translates directly to reduced labor hours per service visit and more targeted parts staging.
  • Auto-Detection of External Battery Cabinets: The GXT5's auto-detection of external battery cabinets means the UPS and service system recognize attached 288V cabinet topology without manual configuration — reducing commissioning error and ensuring the monitoring stack sees every battery module in the chain.
  • Valve-Regulated Lead Acid (VRLA) Battery Chemistry: The sealed, non-spillable, flame-retardant VRLA battery design in the GXT5 cabinet eliminates the ventilation and spill-containment requirements of flooded-cell alternatives. In enclosed server rooms or raised-floor data halls, this matters for both safety compliance and physical space planning.
  • Operating Envelope +32 to +104°F (0 to 40°C): The covered equipment operates across a standard commercial temperature range. If your battery room runs warm — common in edge deployments without dedicated cooling — stay within this envelope; exceeding it accelerates VRLA degradation and will compress the battery life the plan is designed to extend.
  • Compatibility Scoped to GXT5-8000MVRT6UXLN and GXT5-10KMVRT6UXLN: This service SKU is explicitly scoped to the 8kVA and 10kVA 6U rack models in the Liebert GXT5 line. Purchasing it for a different GXT5 variant or a different UPS family will result in a coverage mismatch — verify your installed base model number before ordering.
  • Two-Year Term (BAS2YR): The BAS2YR component of the plan designation signals a baseline two-year coverage window. For facilities on three- to five-year refresh cycles, pairing this with a subsequent renewal or a full equipment refresh at year two keeps battery cabinet coverage continuous without gaps.
  • Multi-Cabinet Coverage (Multi GXT5): The 'Multi' designation in the plan name indicates it addresses multi-cabinet extended-runtime configurations — relevant to the 288V topology this SKU targets. Single-cabinet or standard-runtime GXT5 configurations are a different coverage path.

Integration and Compatibility

The PBRGXT5X-288VBAT (often searched as PBRGXT5X 288VBAT) is purpose-built for sites running the Liebert GXT5-8000MVRT6UXLN or GXT5-10KMVRT6UXLN with 288V external battery cabinets. The GXT5 platform's native auto-detection capability means the UPS communicates cabinet status upstream to whatever monitoring or DCIM layer you have in place — no secondary hardware bridge required for battery status visibility. If you are managing a larger Vertiv UPS and power protection portfolio, verify that each installed GXT5 unit's serial number is registered under this plan prior to the first scheduled service event.

For broader power protection planning in surveillance and security environments, reviewing your uninterruptible power supply architecture alongside battery cabinet service coverage helps ensure runtime and redundancy assumptions hold under real load. Sites deploying high-channel-count NVR racks or large PoE switch stacks should cross-reference UPS runtime calculations against the 288V cabinet's actual discharge curve under rated load — the service plan protects the hardware, but load planning determines whether the runtime is sufficient.

If your facility also runs complementary power protection accessories such as PDUs or static transfer switches in the same rack, Vertiv's service structure often allows multi-component agreements — worth confirming with your service representative to avoid coverage fragmentation across a mixed-power topology.

Frequently Asked Questions

Q: Which UPS models does the PBRGXT5X-288VBAT service plan cover?

A: This plan is compatible with the Liebert® GXT5-8000MVRT6UXLN and Liebert® GXT5-10KMVRT6UXLN UPS systems with 288V external battery cabinets. It is not intended for other GXT5 variants or different Liebert UPS families.

Q: What does the battery health prediction feature actually do on the GXT5?

A: The Liebert® GXT5 continuously monitors battery condition and generates a predicted replacement date based on real battery health data. This lets service teams plan visits and stage replacement parts proactively rather than responding to failures after the fact.

Q: What battery type is used in the GXT5 288V cabinet?

A: The GXT5 external battery cabinet uses valve-regulated, non-spillable, flame-retardant lead acid (VRLA) batteries. The sealed design eliminates venting requirements and hydrogen gas concerns associated with flooded-cell alternatives, making it suitable for enclosed data rooms.

Q: What operating temperature range does the covered equipment support?

A: The Liebert GXT5 system operates from +32°F to +104°F (0°C to 40°C). Sustained operation above this range accelerates VRLA battery degradation and should be avoided to maintain battery life and service plan effectiveness.

Q: Does the GXT5 automatically detect attached external battery cabinets?

A: Yes. The Liebert® GXT5 includes auto-detection of external battery cabinets, so the UPS identifies the connected 288V cabinet topology without requiring manual configuration of each cabinet in the monitoring system.

Q: What does the 'BAS2YR' designation mean in the plan name?

A: BAS2YR indicates a baseline two-year service term. For facilities with longer refresh cycles, plan for a renewal or equipment upgrade at the end of this term to maintain uninterrupted battery cabinet service coverage.

James Everett
James Everett

The PBRGXT5X-288VBAT sits at the intersection of predictive maintenance and high-capacity UPS management — a combination that matters most when you are running 8kVA or 10kVA GXT5 units with 288V external battery cabinets in environments where unplanned downtime has real operational consequences. What distinguishes this plan from a generic break-fix agreement is the GXT5's native battery health prediction: the system tells you when the battery needs replacing based on measured condition, not elapsed time.

Technical Highlights:

  • Battery Health Prediction: The Liebert GXT5 generates replacement date predictions from continuous battery monitoring — service events are triggered by data, not a fixed calendar. On a 288V multi-cabinet topology, this prevents both premature replacement (cost waste) and late replacement (runtime risk).
  • Auto-Detection of External Cabinets: The GXT5 auto-detects attached 288V battery cabinets, so the full extended-runtime configuration is visible to the UPS management layer without manual provisioning of each cabinet unit in the chain.
  • VRLA Battery Chemistry: Valve-regulated, non-spillable, flame-retardant construction means no ventilation buildout, no spill containment — relevant savings in enclosed server rooms and security operations centers where space and safety compliance are both constraints.

Deployment Considerations:

  • Confirm the installed UPS serial numbers match either the GXT5-8000MVRT6UXLN or GXT5-10KMVRT6UXLN before registering under this plan — a model mismatch means coverage won't apply when you need it.
  • The 0–40°C operating range is the hard ceiling for battery life assurance; edge deployments or battery rooms without active cooling that run warm will accelerate VRLA degradation faster than the prediction model accounts for at rated conditions.

This plan is the right fit for data center and critical security infrastructure operators running GXT5 8kVA or 10kVA units with 288V extended-runtime cabinets who need predictive battery lifecycle management — not just reactive repair coverage — built into their maintenance program for a two-year term.

Specifications
Dimensions: 173 mm
Interface Options: Auto-detection of external battery cabinets
Protocols: Liebert® GXT5 provides battery health status and replacement date prediction for intelligent battery health management
Operating Temperature: +32 to +104 °F (0 to 40 °C)
General: Compatible with Liebert® GXT5-8000MVRT6UXLN and Liebert® GXT5-10KMVRT6UXLN, Liebert GXT5 UPS systems
UPS Topology: Battery Type: Valve-regulated, non-spillable, flame-retardant, lead acid
Q&A
Reviews

Vertiv GXT5 288VBAT - PBRGXT5X-288VBAT

$6,467.00
$4,434.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources