Power Supplies
Showing Results for Power Supplies
-
Altronix
SKU: EFLOW6NX
Altronix EFLOW6NX Two (2) Output Power Supply/Charger
8-output 12/24VDC power supply with battery backup for security systems
- 6A total capacity across 8 independent outputs for multi-device distribution
- Automatic battery switchover with AC Fail and Low Battery supervision
- UL Listed 120VAC input with Fire Alarm Disconnect function
$539.82 $311.99 Save $227.83 -
Altronix
SKU: EFLOW6NX16
Altronix EFLOW6NX16 Power Supply/Charger w/Fire Alarm Discon
8-channel 12/24VDC power supply with fire alarm disconnect and battery backup
- Fire alarm disconnect function meets emergency shutdown code requirements
- 8 independent channels at selectable 12/24VDC for mixed-voltage systems
- Battery backup with AC fail, low battery, and battery presence supervision
$620.77 $357.99 Save $262.78 -
Altronix
SKU: EFLOW6NX16D
Altronix EFLOW6NX16D Power Supply/Charger w/Fire Alarm Discon
8-output 12/24VDC supply with fire alarm disconnect for life safety
- 8 independent outputs at 4A each with 6A total current capacity
- Integrated fire alarm disconnect relay for emergency power sequencing
- Battery backup with AC fail, low battery, and battery presence supervision
$620.77 $357.99 Save $262.78 -
Altronix
SKU: EFLOW6NX8
Altronix EFLOW6NX8 Power Supply/Charger w/Fire Alarm Discon
Eight-output 12/24VDC supply with battery backup and fire alarm disconnect
- 8 isolated channels with 6A total current and per-channel limiting
- Integrated battery charger maintains power during AC loss
- Fire alarm disconnect relay automatically shuts down non-critical outputs
$611.17 $351.99 Save $259.18 -
Altronix
SKU: EFLOW6NX8D
Altronix EFLOW6NX8D Power Supply/Charger w/Fire Alarm Discon
8-output 12/24VDC supply with battery backup and fire alarm disconnect
- 8 independently regulated outputs at 6A total capacity for multi-device systems
- Integrated fire alarm disconnect relay for emergency circuit isolation
- Battery backup with automatic charging plus AC Fail and Low Battery supervision
$611.17 $351.99 Save $259.18 -
Altronix
SKU: FIRESWITCH108
Altronix FIRESWITCH108 24VDC 10A NAC Power Supply
24VDC 10A power supply with segregated Class A/B circuits for access control
- 4 Class A + 8 Class B circuits isolate critical devices from load-shedding
- 10A continuous output across all circuits from single 115VAC input
- Ethernet remote monitoring and optional battery backup modules
$1,175.94 $674.99 Save $500.95 -
Altronix
SKU: LPS3
Altronix LPS3 Linear Power Supply 12/24VDC 0.5A
Selectable 12/24VDC linear supply for security systems, 0.5A output
- Choose 12VDC or 24VDC output via board configuration—one unit fits mixed-voltage deployments
- Linear regulation minimizes RF noise for stable analog sensor and legacy alarm operation
- Accepts standard 16/24VAC transformer input; mounts in 12"H × 8"W × 6"D form factor
In stock · Ships same business day$86.33 $85.99 Save $0.34 -
Altronix
SKU: LPS3AC
Altronix LPS3AC Linear Power Supply/Charger 12/24VDC
Compact 12/24VDC linear supply with integrated battery charging for access control
- Selectable 12VDC or 24VDC output with 0.5–0.75A current capacity
- Built-in battery charger with AC fail and low battery supervision signals
- Board-form factor designed for OEM integration in small security installations
$116.27 $115.99 Save $0.28 -
Altronix
SKU: LPS3C12X
Altronix LPS3C12X 12VDC 2.5A Linear Power Supply with Battery Backup
12VDC 2.5A linear supply with integrated battery backup for access control
- 2.5A continuous output powers 2–3 electric strikes plus control logic
- Linear regulation minimizes noise for sensitive alarm and reader circuits
- Built-in battery charging and AC/low-battery supervision in one enclosure
In stock · Ships same business day$403.69 $234.99 Save $168.70 -
Altronix
SKU: LPS3C24X
Altronix LPS3C24X 24VDC 2.5A Linear Power Supply
24VDC 2.5A regulated supply with AC fail supervision for security
- Single 24VDC output at 2.5A (60W) powers readers, strikes, cameras
- Accepts 16VAC or 24VAC input—selectable for retrofit or new installs
- AC fail relay alerts system controller to mains power loss instantly
In stock · Ships same business day$379.81 $244.99 Save $134.82 -
Altronix
SKU: LPS3R
Altronix LPS3R 12/24VDC 2.5A Linear Power Supply
Selectable 12/24VDC linear supply with 2.5A output for access control
- 2.5A continuous capacity with 18-foot pre-installed leads for quick setup
- AC fail relay alerts system to power loss in card readers and locks
- Compact rack-mount design fits small-to-medium security installations
$116.42 $115.99 Save $0.43 -
Altronix
SKU: LPS3WP12
Altronix LPS3WP12 12VDC Linear Power Supply
Outdoor 12VDC linear supply for security systems, 0.5A at 16/24VAC input
- Weather-resistant enclosure rated for exterior mounting in harsh conditions
- Single 12VDC output at 0.5A for access control and camera applications
- Linear design eliminates noise for clean power to sensitive security equipment
$440.24 $283.99 Save $156.25 -
Altronix
SKU: LPS3WP24
Altronix LPS3WP24 24VDC Linear Power Supply
Single-output 24VDC linear supply with AC fail supervision for access control
- 24VDC regulated output at 0.5A max; linear design minimizes noise on reader circuits
- AC fail supervision detects power loss and triggers alarm signal for compliance audits
- Compact DIN-rail or wall mount; 115VAC input; 12" × 8" × 6" footprint
In stock · Ships same business day$466.14 $300.99 Save $165.15 -
Altronix
SKU: MAXFIT11FE
Altronix MAXFIT11FE Dual 12/24VDC 4A Power Supply
Dual 12/24VDC 4A power supply with selectable voltage per channel
- Two isolated 4A outputs at 12VDC or 24VDC, field-selectable per channel
- Expandable modular architecture grows with system without full replacement
- BC750 steel enclosure with DIN-rail mounting for compact cabinet install
$950.28 $612.99 Save $337.29 -
Altronix
SKU: MAXFIT13FE
Altronix MAXFIT13FE 12/24VDC 10A Power Supply
Compact 12/24VDC 10A supply for access control and surveillance
- Selectable 12VDC or 24VDC output for mixed security device loads
- 10A rating supports multiple cameras, controllers, and sensors
- MAXFIT enclosure fits 19-inch rack and wall-mount cabinets
$962.01 $620.99 Save $341.02 -
Altronix
SKU: MAXFIT33E
Altronix MAXFIT33E Dual-Channel 12/24VDC Power Supply
Dual-channel 12/24VDC supply, 6A per channel, stackable design
- Two independent 6-ampere channels with per-channel voltage selection
- Mix 12VDC and 24VDC loads simultaneously without separate supplies
- Stackable architecture scales across multi-zone security deployments
$1,100.56 $635.99 Save $464.57
Power Supplies
Power supplies provide stable and regulated power for surveillance cameras, access control devices, and intercom systems. Selecting the proper voltage, amperage, and redundancy configuration ensures reliable operation and minimizes system downtime in commercial environments.
Plan Your Deployment
- Voltage and amperage requirements for connected devices
- Centralized vs distributed power architecture
- Redundancy and failover considerations
- Indoor vs outdoor installation requirements
- Code compliance and surge protection planning
Power Supplies — Engineering-Grade Power Distribution for Commercial Deployments
This category covers 193 working models of power supplies sourced manufacturer-direct or through channel-direct US distribution. Build the rest of your system around the architectural choices below — compatibility, environmental rating, and lifecycle decisions made here propagate through every downstream component you specify.
What to Look For
Voltage and amperage requirements come from the connected load. Cameras and access-control hardware typically use 12VDC or 24VAC; PoE-powered devices need a PoE injector or switch instead of a traditional supply. Sum the steady-state current draw across all devices on the supply, then add 25-30% headroom for inrush and growth. Undersized supplies fail quickly under sustained load.
Linear, switching, and PoE supplies have different efficiency, noise, and form-factor characteristics. Switching supplies are smaller and cooler-running but introduce switching noise that can affect audio circuits. Linear supplies run quieter electrically but generate more heat and weigh more. PoE injectors and switches are standard for IP cameras and access readers — pick by port count, power budget, and management capability.
Output redundancy and battery backup are the distinguishing features at the high end. Multi-output supplies with individually-fused outputs isolate device failures so one shorted camera doesn't take down the rest. Battery-backed supplies maintain operation during AC failure — code-mandated on most access-control and emergency systems. Sizing the battery for actual runtime requirement is more important than headline Ah capacity.
Enclosure type, mounting, and certification matter for code compliance and field reliability. NEMA-rated enclosures for outdoor/wet locations; lockable enclosures for tamper-resistant installs. UL 294 listing for access-control supplies; UL 1481 for fire-alarm supplies. Verify the AHJ's listing requirements before ordering — many jurisdictions reject non-listed supplies in commercial life-safety installs.
Key Specs in This Category
| Spec | Available Options |
|---|---|
| Resolution | 4MP, 2MP, 0MP, 8MP, 5MP, 20MP+ |
| IP Rating | IP65, IP68, IP66, IP67 |
| Connectivity | Wired, Bluetooth, Wi-Fi |
| Power | AC/DC, PoE+, PoE |
| Storage | microSD |
| Type | Power Supply, Accessory, Power Accessories, Switch, Controller, Mobile Computer, Power Adapter, DVR |
Top Brands in This Category
Frequently Asked Questions
Do I need a battery backup on my power supply?
For access control on egress doors, fire alarm systems, and most security-monitored installations — yes, code requires it. Battery backup runtime is typically 4 hours minimum for access control (24 hours for fire alarm). For surveillance cameras alone, battery backup is optional but recommended; a 30-minute UPS bridge handles most utility-power glitches and prevents reboot cycles that affect recorded video continuity.
What size power supply do I need for 8 PoE cameras?
If using a PoE switch, sum the per-camera PoE class budget: 8 cameras at 802.3at (PoE+, 30W max) need a switch with at least 240W total PoE budget. Add 20-30% headroom. Many 8-port PoE+ switches advertise 130W total budget — undersized for full-load 802.3at use. For 802.3bt (PoE++, 60-90W) devices like multi-imagers or large PTZs, plan even more aggressively.
Can I mix 12VDC and 24VAC devices on one supply?
Multi-output supplies (Altronix AL600ULPD8, LifeSafety FPO75) provide both 12VDC and 24VAC outputs from a single chassis, each individually fused. Mixing the two on a single output is not safe — voltage and waveform are incompatible. For larger sites, separate dedicated supplies per voltage simplify troubleshooting and isolate failures.
How do I calculate voltage drop on long cable runs?
Voltage drop depends on conductor gauge, current draw, and cable length. For 12VDC at 2A over 100 feet, 18 AWG drops roughly 1V (5%) — borderline acceptable. 16 AWG drops half that. For runs over 100 feet at sustained current, use a 24V supply at the source and step down at the device, or move to PoE which tolerates longer runs at typical commercial distances.
What's the difference between a power supply and a PoE injector?
A traditional power supply delivers DC (or AC) to a device through a dedicated power cable. A PoE injector adds DC power to the unused pairs of an Ethernet cable, so the device receives both power and data on the same Cat5e/Cat6. PoE simplifies installation and is the dominant choice for IP cameras and modern access readers. Traditional supplies are still preferred for high-current devices like maglocks and analog camera installations.
Need help choosing? Talk to a Senior Specialist — direct line 877-277-7147 or request a quote.