Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: PR2VSD0896WH
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 41% OFF

Panduit PR2VSD0896WH 52RU Dual-Sided Cable Manager

Panduit PR2VSD0896WH PatchRunner 2 Dual-Sided Vertical Cable Manager High-density switching and patching environments demand cable management that kee…

$2,327.31 $1,368.99 SAVE $958

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit PR2VSD0896WH 52RU Dual-Sided Cable Manager

$2,327.31
$1,368.99

Overview

SKU: PR2VSD0896WH
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit PR2VSD0896WH PatchRunner 2 Dual-Sided Vertical Cable Manager

High-density switching and patching environments demand cable management that keeps pace with port counts without sacrificing accessibility or airflow. The Panduit PR2VSD0896WH PatchRunner 2 dual-sided vertical manager delivers 52 RU of front-and-rear cable routing capacity in an 8-inch-wide footprint, eliminating the cable congestion that chokes patch-panel serviceability and blocks cooling airflow in enterprise network cores and datacenter top-of-rack installations. The fully pre-assembled design drops installation time to minutes—mount the backbone, snap on the included full-length dual-hinging door, and route cables through molded fingers that guide without snagging. UL 2416 and CSA C22.2 certifications confirm the structural and fire-safety performance required for mission-critical network infrastructure.

Key Features

  • Dual-sided design — front and rear cable routing in a single 8-inch-wide unit
  • 52 RU full-height coverage — matches standard rack depth for floor-to-ceiling cable management
  • Pre-assembled construction — metal backbone and molded plastic fingers ship ready to install
  • Full-length dual-hinging push-to-close door — secure cables while maintaining quick access for moves/adds/changes
  • 8-inch width accommodates high-density patch cabling without lateral rack space waste
  • Compatible with 19-inch and 23-inch EIA racks — fits standard datacenter and telco rack standards
  • UL 2416 and CSA C22.2 certified — meets North American fire and structural safety requirements
  • RoHS compliant — lead-free materials suitable for environmentally regulated deployments
  • White finish — coordinates with white rack and patch-panel aesthetics

Dual-Sided Architecture for Front-and-Rear Routing
The PR2VSD0896WH's dual-sided design solves the access problem inherent in single-sided managers. The metal backbone mounts vertically between rack rails, with molded plastic fingers on both the front and rear faces. Patch cords route through the front side for switch-to-patch-panel connections, while backbone cables route through the rear for uplink and cross-connect runs. This separation prevents the cable layering that forces technicians to disrupt entire bundles during MAC-day operations. The 8-inch width provides enough depth to accommodate bend-radius requirements for Category 6A and fiber trunk cables without crimping or kinking, while the finger spacing prevents individual cables from sagging into airflow paths. Each finger is molded from durable plastic with rounded edges that eliminate the sharp contact points known to abrade cable jackets during repeated service cycles. The backbone's steel construction supports the cumulative weight of hundreds of patch cords without flexing—critical in 10G and 25G environments where cable mass can exceed 50 pounds per vertical run.

Full-Length Door with Dual-Hinge Push-to-Close Mechanism
The included full-length door spans all 52 RU, providing cable containment and a clean aesthetic finish. The dual-hinge design allows the door to swing open from either side, eliminating the need to navigate around adjacent racks or cable trays during service. The push-to-close latch mechanism requires no keys or tools—press the door flush, and the latch engages automatically. This matters during rapid-response outages when fumbling with keys wastes critical minutes. The door's perforated metal construction maintains airflow visibility, allowing thermal monitoring cameras and visual inspections to confirm cable bundle temperatures without opening the manager. The hinge mounting is reinforced to handle the repeated open-close cycles typical in high-churn environments—enterprise network cores routinely see 20–30 MAC events per month, and the hinge's steel pivot points are rated for thousands of cycles without loosening or misalignment.

Pre-Assembled Design Cuts Installation Time and Labor Cost
Unlike field-assembled managers that arrive as bins of brackets, fingers, and hardware, the PR2VSD0896WH ships as a complete unit. The backbone, fingers, and door are already attached—installers simply mount the unit to the rack's vertical rails using the included hardware, confirm level alignment, and begin routing cables. This pre-assembly eliminates the 60–90 minutes typically spent snapping finger sections into backbone channels and aligning door hinges. In multi-rack deployments—such as a new datacenter POD with 12 racks—the time savings compound to hours of billable labor. The pre-assembled approach also reduces the risk of finger misalignment or missing hardware, which can leave gaps in cable coverage or loose sections that rattle during facility vibration.

Deployment Context: Enterprise Cores, Datacenter ToR, and Telco Distribution
The PR2VSD0896WH fits high-density environments where patch-panel counts exceed 96 ports per rack. Typical deployments include enterprise network cores with stacked 48-port switches, datacenter top-of-rack installations feeding blade chassis or pizza-box servers, and telco central-office distribution frames where copper and fiber cross-connects converge. The 52 RU height makes the manager suitable for full-height 45U or 48U racks, providing cable management that scales with the rack's usable space. The dual-sided design is especially valuable in back-to-back rack rows where front-facing cables serve user equipment and rear-facing cables connect to backbone trunks or building entrance facilities. The 8-inch width is narrow enough to leave room for adjacent managers or power distribution units without forcing rack spacing beyond standard 24-inch depths.

Standards Compliance: UL 2416, CSA C22.2, and RoHS
UL 2416 certification confirms the manager meets flammability and structural loading requirements for communications equipment installations. This certification is required for insurance compliance in many commercial and institutional facilities, and it signals that the product has passed third-party testing for fire propagation, smoke generation, and load-bearing capacity. CSA C22.2 certification extends that compliance to Canadian installations, covering the same fire and structural criteria under Canadian electrical code. RoHS compliance ensures the product contains no lead, mercury, cadmium, or other restricted substances, making it suitable for deployments in EU member states or U.S. facilities with environmental procurement mandates. These certifications are non-negotiable in government, healthcare, and financial-sector installations where equipment failure or non-compliance can trigger audit findings or contract penalties.

The Panduit PR2VSD0896WH PatchRunner 2 manager is the solution for integrators and datacenter operators who need to contain hundreds of patch cords without sacrificing accessibility, airflow visibility, or installation speed. The dual-sided design, pre-assembled construction, and certified compliance make it the default choice for racks where cable chaos is not an option.

Specifications
Product Type: Dual-Sided Vertical Cable Manager
Sub-Brand: PatchRunner 2
Height: 52 RU (95.88 in / 2435.2 mm)
Width: 8 in (203.2 mm)
Color: White
Rack Compatibility: 19 in and 23 in EIA Racks
Construction: Metal backbone with molded plastic fingers
Door Type: Full-length metal dual-hinging push-to-close
Sides: Dual-sided (front and rear cable routing)
Assembly: Pre-assembled
UL Listing: UL 2416
CSA Certification: CSA C22.2
RoHS Compliance: Yes
Package Quantity: 1
UPC: 61305645062
Manufacturer: Panduit
MPN: PR2VSD0896WH
Type: Cable Manager
Sub Brand: PatchRunner™ 2
Height In: 95.88
Height Mm: 2435.2
Width In: 8
Width Mm: 203.2
Carton Qty: 0
Package Qty: 1
Standards: RoHS Compliant, UL 2416, CSA C22.2
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources