Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Hubbell HC6AGN15P Cat6A Plenum Patch Cord — 15 ft Green

Overview

The Hubbell HC6AGN15P is a 15-foot Cat6A patch cord from the Ascent line, built with a plenum-rated jacket for deployment in air-handling spaces where fire code requires CMP-rated cabling. The green jacket provides instant visual lane identification in dense patch panels — a practical detail in structured cabling environments where color-coding by VLAN, floor, or application is standard practice. If you're building out network infrastructure in a commercial facility with plenum ceilings or raised-floor air returns, the plenum rating is not optional — it's a code requirement that this cable meets.

Key Features

  • Cat6A Performance: Rated to Category 6A standards, supporting 10 Gigabit Ethernet at up to 100 meters — meaning this 15-foot run won't be your bottleneck when connected to 10GbE switches or servers. Cat6A also provides superior alien crosstalk rejection compared to Cat6, which matters in dense cable trays where cables run parallel for extended distances.
  • Plenum (CMP) Jacket Rating: The plenum jacket meets CMP fire ratings required by NEC and most local codes for cables routed through HVAC air-handling spaces. Substituting a riser or standard jacket cable in a plenum space is a code violation — this cord eliminates that risk. See the full structured cabling catalog for plenum-rated bulk cable and panel options to match.
  • Green Jacket — Color-Lane Discipline: Green is commonly assigned to voice, guest networks, or specific VLANs depending on your site standard. At 15 feet, this cord fits comfortably within a single rack or between adjacent racks without excess slack cluttering airflow.
  • Ascent Series Construction: Part of Hubbell's Ascent Hubbell structured cabling line, designed for commercial and enterprise environments where channel performance and consistent termination quality are required across a full system warranty.
  • Pre-Terminated Convenience: Factory-terminated connectors eliminate field-termination variability — each end is crimped and tested at the factory, reducing the chance of marginal connections that cause intermittent 10G link failures in the field.

Integration & Compatibility

The HC6AGN15P is compatible with any Cat6A or backward-compatible Cat6/Cat5e RJ-45 port. It pairs directly with Cat6A keystone jacks, patch panels, and PoE switches without adapters. For camera infrastructure runs, use this cord for the patch panel-to-switch hop; pair with plenum-rated Cat6A bulk cable for in-wall or above-ceiling horizontal runs. Consult a structured cabling planning guide to match cord lengths to your patch panel layout and minimize slack management issues in high-density enclosures.

Frequently Asked Questions

Q: Is the HC6AGN15P rated for air-handling plenum spaces?

A: Yes. The HC6AGN15P carries a plenum (CMP) jacket rating, making it code-compliant for installation in HVAC air-handling spaces where standard or riser-rated cables are not permitted.

Q: What speed does Cat6A support?

A: Cat6A supports 10 Gigabit Ethernet (10GbE) at full 100-meter channel distances. For a 15-foot patch cord application, it will also run 1GbE and 2.5GbE without issue.

Q: Can I use the HC6AGN15P with Cat6 or Cat5e patch panels?

A: Yes. Cat6A patch cords are backward-compatible with Cat6 and Cat5e infrastructure, though the channel will perform only to the lowest-rated component in the link.

Q: Why is the jacket green?

A: Green is a standard color-coding option used to differentiate network segments, VLANs, or application types in structured cabling environments. It helps technicians trace and manage connections visually in dense patch fields.

Q: Is 15 feet the right length for within-rack patching?

A: For within-rack or adjacent-rack connections, 15 feet is generally on the longer end — it allows routing through cable managers with some slack. For tight within-rack runs, shorter lengths (3–7 ft) reduce congestion; 15 feet is better suited for inter-rack or moderate-distance panel-to-switch hops.

Karl Wilson
Karl Wilson

The HC6AGN15P is the cord I spec when a project calls for 10GbE infrastructure in a building with plenum ceilings and the AHJ is strict about CMP ratings — which is most commercial projects I see. The plenum jacket is the defining spec here; everything else (Cat6A bandwidth, green color, 15-foot length) is standard fare, but getting the jacket rating wrong means a failed inspection and a rip-and-replace at the worst possible time in a project schedule.

Technical Highlights:

  • CMP Plenum Rating: Meets NEC requirements for cables routed through air-handling spaces — non-negotiable in commercial buildings with open plenum ceilings. A riser-rated (CMR) cord in the same space is a code violation regardless of performance.
  • Cat6A Channel Support: Supports 10GbE across the full 100-meter standard channel. At 15 feet, you have plenty of headroom — this cord will not be a limiting factor in any current or near-future 10G deployment.
  • Green Color Coding: Meaningful only if your site has a documented color standard. If it doesn't, establish one before you deploy — retroactive color-coding in a full rack is a significant labor cost.

Deployment Considerations:

  • Confirm your patch panel and switch ports are also Cat6A rated if you need the full 10GbE channel guarantee; mixing Cat6 panels with Cat6A cords limits you to Cat6 channel performance.
  • At 15 feet, plan your cable management before you run — excess slack in a high-density patch field kills airflow and makes future moves, adds, and changes slower. Size down to 7-foot cords for tight within-rack runs if layout allows.

This cord is the right call for new commercial build-outs or data center refreshes in plenum-ceiling environments where 10GbE is being deployed and color-lane discipline is part of the installation standard.

Specifications
Overview: Patch Cord Ascent Cat6A Plenum Green 15ft.
Jacket Rating: PLENUM
Length: 15 FT
Q&A
Reviews
Have Questions?

Hubbell Patch Cord Ascent Cat6A Plenum Green 15ft. - HC6AGN15P

$105.00
$104.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources