Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FWTYL7575LNM040
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 35% OFF

Panduit FWTYL7575LNM040 OM5 12F Trunk 40m LSZH

Panduit FWTYL7575LNM040 QuickNet OM5 12-Fiber Trunk Cable Assembly The Panduit FWTYL7575LNM040 is a 40-meter pre-terminated OM5 trunk cable assembly e…

$2,257.82 $1,462.99 SAVE $795

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FWTYL7575LNM040 OM5 12F Trunk 40m LSZH

$2,257.82
$1,462.99

Overview

SKU: FWTYL7575LNM040
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FWTYL7575LNM040 QuickNet OM5 12-Fiber Trunk Cable Assembly

The Panduit FWTYL7575LNM040 is a 40-meter pre-terminated OM5 trunk cable assembly engineered for high-density data center deployments where space, insertion loss, and future-proofing drive infrastructure decisions. This 12-fiber trunk uses wideband multimode OM5 fiber (50µm core) to support short-wave division multiplexing (SWDM) across four wavelengths (850-950nm), delivering 4x the effective bandwidth of OM4 over the same physical fiber count. The assembly features PanMPO female connectors on both ends with HD Flex Transition Method B polarity, a low-smoke zero-halogen (LSZH) jacket rated for enclosed equipment spaces, and Panduit's Ultra Insertion Loss specification to ensure margin for 40/100/400GbE applications at distances up to 150 meters over OM5. The lime-green jacket provides instant visual identification per TIA-568 OM5 color coding, and the reduced-diameter HD Flex cable design reclaims 30-40% of pathway space compared to legacy OM3/OM4 trunk assemblies—critical when retrofitting existing cable trays or planning future capacity in congested data halls.

Key Features

  • OM5 Wideband Multimode Fiber: 50µm core optimized for 850-950nm SWDM, supporting 40G/100G SR4 and emerging 400G SR4.2 applications with 4x effective lanes per physical fiber pair compared to OM4
  • Pre-Terminated 12-Fiber PanMPO-to-PanMPO: Factory-terminated connectors eliminate field polishing, reduce installation time by 80% vs. field termination, and guarantee end-to-end insertion loss performance under Ultra IL spec
  • HD Flex Transition Method B Polarity: Key-up-to-key-up connector orientation with internal fiber crossover for straight-through trunk-to-breakout deployments; compatible with Panduit QuickNet cassettes and modules
  • LSZH Jacket (Low Smoke Zero Halogen): Meets IEC 60332-1 and 60754 fire/toxicity standards for enclosed data halls, telecommunications rooms, and international installations where PVC is prohibited
  • Ultra Insertion Loss Specification: Maximum 0.35 dB per mated connector pair and 0.5 dB total channel IL (connector + cable), providing headroom for 100GBASE-SR4 (1.9 dB budget) and 40GBASE-SR4 (1.5 dB budget) at 40m
  • 40-Meter Length (131 ft): Spans typical data center row-to-row or top-of-rack-to-end-of-row aggregation switch distances without mid-span splicing
  • Small-Diameter HD Flex Cable: 30-40% reduced cross-sectional area vs. standard round OM4 trunks; tighter bend radius (10x cable OD dynamic, 20x static) for high-density ladder rack and overhead tray routing
  • Lime Color Coding: TIA-568-C.3 OM5 identification standard—immediate visual confirmation during adds/moves/changes to prevent cross-patching OM3/OM4/OM5 links
  • QuickNet System Integration: Drop-in compatibility with Panduit's modular fiber infrastructure (FHD cassettes, FAP adapter panels, FQPP patch panels) for mix-and-match duplex LC, MPO, or future connector migrations
  • 50µm Multimode Core / 125µm Cladding: Meets TIA-492-AAAD and IEC 60793-2-10 Type A1a.3 fiber geometry and optical specs; backward-compatible with OM3/OM4 transceivers at reduced distance

OM5 fiber was standardized in TIA-492-AAAE and ISO/IEC 11801-1 Ed. 1.2 specifically to address the bandwidth crunch in hyperscale and enterprise data centers migrating to 40/100/400GbE without ripping out multimode infrastructure. Unlike OM3 and OM4, which optimize a single 850nm wavelength, OM5 wideband multimode fiber (WBMMF) is manufactured with tightly controlled refractive index profiles across the 850-950nm window, enabling short-wave division multiplexing (SWDM) transceivers to transmit four independent 25G or 50G lanes over four wavelengths on a single fiber pair. This means a 12-fiber OM5 trunk like the FWTYL7575LNM040 can support three 100GBASE-SR4 links (each using 8 fibers for Tx/Rx) or one 400GBASE-SR4.2 link (using 8 fibers for 8x 50G lanes) with four fibers as spares—delivering the same throughput as a 24- or 48-fiber OM4 trunk in half the physical space. The Ultra Insertion Loss designation guarantees maximum connector IL of 0.35 dB and total channel IL under 0.5 dB at 40 meters, well inside the IEEE 802.3ba 1.9 dB link budget for 100GBASE-SR4 and the 1.5 dB budget for 40GBASE-SR4. This IL headroom compensates for aging, contamination, and temperature cycling over a 20+ year infrastructure lifespan. The PanMPO connectors use precision-molded MT ferrules with 12-fiber ribbonized alignment and a push-pull latch design; the female (socket) interface on both ends accepts keyed male (plug) connectors or mating adapters in FAP or FHD modules. Method B polarity (key-up/key-up with internal fiber swap on one end) is the TIA-568-C.0 standard for backbone trunks feeding Method A or Method C breakout cassettes, ensuring Tx lanes on one switch map to Rx lanes on the far end without field rewiring.

In practice, the FWTYL7575LNM040 suits core-to-aggregation or aggregation-to-access tier links in leaf-spine fabrics where each 40-meter trunk run connects a top-of-rack switch at row-end to a spine switch in a central MDA (main distribution area). The 131-foot length accommodates typical raised-floor data center geometries—45-60 feet of horizontal cable tray run plus vertical drops, slack loops, and pathway detours—without requiring mid-span fusion splicing or bulkhead pass-throughs that add insertion loss and failure points. The HD Flex cable construction uses a flat or oval cross-section with reduced outer diameter (typically 5-6mm for 12-fiber vs. 8-9mm for round OM4), allowing installers to stack more trunks per ladder rack rung or U-space in vertical cable managers; a single 4-inch-wide by 2-inch-tall tray can carry 60+ HD Flex trunks where only 30-40 round cables would fit. The LSZH jacket is mandatory in many international markets (EU, APAC) under building codes that restrict PVC in occupied or enclosed spaces due to toxic hydrogen chloride and dense smoke during combustion. Even in North America, colocation providers and hyperscale operators increasingly specify LSZH for data halls without dedicated HVAC smoke evacuation, as LSZH cables self-extinguish and produce 10x less smoke opacity than plenum-rated PVC per ASTM E662. The lime green jacket provides instant differentiation from aqua (OM3), erika violet (OM4), and legacy orange (OM1/OM2) fibers during MACs (moves/adds/changes), preventing the common field error of cross-patching OM5 transceivers to OM3 infrastructure, which limits 100G-SR4 reach to 70 meters instead of OM5's rated 150 meters. Panduit's QuickNet modular system allows this trunk to plug into FHD cassettes (which break out 12-fiber MPO to six duplex LC ports) or FAP adapter panels (MPO passthrough for MPO-to-MPO switch ports), so the same trunk supports both traditional LC-based 10G/25G SFP+ optics and next-generation 100G/400G QSFP28/QSFP-DD MPO interfaces as switch hardware evolves.

The FWTYL7775LNM040 meets TIA-568-C.3 (balanced twisted-pair and optical fiber cabling), TIA-604-5 (FOCIS-5 MPO connector intermateability), ISO/IEC 11801 Ed. 3 (generic cabling for customer premises), TIA-492-AAAD (OM5 fiber performance), and IEC 60793-2-10 Type A1a.3 (multimode fiber geometry). The assembly is RoHS-compliant under EU Directive 2011/65/EU (lead, mercury, cadmium, and hexavalent chromium limits) and ships with factory test reports documenting per-fiber insertion loss, return loss, and length to ensure day-one compliance with IEEE 802.3ba link budgets. The QuickNet ecosystem is particularly valuable in multi-vendor environments: unlike proprietary MPO systems that lock you into a single cassette or module vendor, Panduit's use of industry-standard TIA-568 Method A/B/C polarity and MT ferrule pinout means this trunk interoperates with any TIA-compliant breakout cassette, protecting your infrastructure investment if switch or optics vendors change mid-lifecycle. For integrators designing 40/100G spine fabrics or retrofitting 10G access layers to 25G, the 40-meter length hits the sweet spot—long enough to eliminate the need for intermediate distribution frames in single-row or small pod deployments, short enough to stay well under OM5's 150-meter 100G-SR4 reach with margin for future transceiver generations. If your data center roadmap includes 400G spine uplinks, OM5 SWDM support means you can reuse this 12-fiber trunk for one 400GBASE-SR4.2 link (8 fibers active) instead of deploying a new 24-fiber OM4 trunk, cutting pathway congestion and material cost in half while maintaining the same 400G throughput.

Specifications
Manufacturer: Panduit
MPN: FWTYL7575LNM040
Product Type: Trunk Cable Assembly
Sub-Brand: QuickNet
Fiber Type: OM5 Wideband Multimode
Number of Fibers: 12
Fiber Core Diameter: 50µm
Connector Type A: PanMPO Female
Connector Type B: PanMPO Female
Polarity Method: Method B (Key-Up to Key-Up)
Cable Length: 40 meters (131.23 feet)
Jacket Type: LSZH (Low Smoke Zero Halogen)
Jacket Color: Lime
Insertion Loss Spec: Ultra IL (≤0.35 dB per connector, ≤0.5 dB channel)
Application: Data Center Backbone, 40G/100G/400G Links
Standards Compliance: TIA-568-C.3, ISO/IEC 11801, TIA-604-5 (FOCIS-5), TIA-492-AAAD, IEC 60793-2-10 A1a.3
Flammability Rating: IEC 60332-1, IEC 60754 LSZH
RoHS Compliant: Yes
UPC: 61305636036
Package Quantity: 1 each
Type: Fiber Optic Trunk Cable
Connectivity: PanMPO to PanMPO
Sub Brand: QuickNet™
Fiber Count: 12
Length Ft: 131.23
Length M: 40
Carton Qty: 0
Package Qty: 1
Standards: Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-5), TIA/EIA-568-C.1, RoHS compliant,TIA-492-AAAD, IED 60793-2-10 type A1a.3
Cable Category: fiber-optic-systems
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources