Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FRZTP78X001M004
Condition: New
Write a Review 31% OFF

Panduit FRZTP78X001M004 OM4 12F Plenum Interconnect 4m

Panduit FRZTP78X001M004 OM4 12-Fiber Plenum Interconnect The Panduit FRZTP78X001M004 delivers a factory-terminated, plenum-rated OM4 multimode backbon…

$694.24 $479.99 SAVE $214
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FRZTP78X001M004 OM4 12F Plenum Interconnect 4m

$694.24
$479.99

Overview

SKU: FRZTP78X001M004
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZTP78X001M004 OM4 12-Fiber Plenum Interconnect

The Panduit FRZTP78X001M004 delivers a factory-terminated, plenum-rated OM4 multimode backbone trunk engineered for high-density data center and enterprise telecom environments demanding rapid deployment without field splicing. This 4-meter (13.1-foot) interconnect features PanMPO female-to-male connectors configured in Polarity Method A, supporting 10/40/100 Gigabit Ethernet applications over 50/125µm laser-optimized multimode fiber. Pre-terminated at the factory and 100% insertion-loss tested, this trunk eliminates the variables introduced by field termination—ensuring consistent performance, reducing installation labor by up to 80%, and meeting TIA-568.3-D and ISO/IEC 11801 structured cabling standards out of the box.

Key Features

  • OM4 laser-optimized 50/125µm multimode fiber supports 10GBASE-SR to 400m, 40GBASE-SR4 to 150m, and 100GBASE-SR10 to 100m
  • Factory-terminated PanMPO connectors with Method A polarity—straight-through mapping compatible with IEEE 802.3 parallel optics standards
  • Plenum-rated (OFNP) jacket meets NEC Article 770 for installation in air-handling spaces without conduit
  • 12-fiber configuration supports one 40G or 100G channel, or twelve independent 10G links when broken out
  • Pre-tested to ≤0.35 dB insertion loss per mated connector pair—eliminates post-install certification delays
  • 4-meter length ideal for cross-connect applications between adjacent racks or intra-row distribution

Pre-terminated MPO trunks like the FRZTP78X001M004 solve three chronic problems in high-speed data center builds: labor cost overruns from field splicing, inconsistent loss budgets that fail channel certification, and project delays waiting for fusion-splice techs. A field-terminated 12-fiber trunk typically requires 90–120 minutes of skilled labor (splicing, testing, documentation) and introduces 0.1–0.5 dB of variability per splice point depending on cleave quality and tech experience. Panduit's factory process uses automated polishing and interferometric inspection to guarantee ≤0.35 dB per connection—tighter than the 0.75 dB TIA-568.3-D limit—and ships with serialized test reports. The female-to-male configuration supports daisy-chaining: female end connects to equipment or patch panel, male end connects to the next female trunk or bulkhead adapter, maintaining polarity without adapters or crossover modules. For 40GBASE-SR4 deployments, this means each trunk carries all four transmit and four receive lanes in a single pull, and the Polarity A pinout ensures Tx on one end aligns with Rx on the far end without flipping or key-up/key-down adapter games.

In ANSI/TIA-942-B Rated-3 and Rated-4 data centers, backbone cabling between main distribution areas and horizontal distribution areas must meet plenum flammability requirements when routed through overhead cable trays above drop ceilings classified as air-return plenums. The OFNP jacket on this trunk passes UL 910 (Steiner Tunnel) flame and smoke tests, allowing installation without metallic conduit—saving 60–70% on pathway materials and cutting pull tension limits that would otherwise risk fiber microbending. The OM4 grade supports current 10G SFP+ links and provides headroom for migration to 40G QSFP+ or 100G QSFP28 optics without re-cabling—critical in facilities with 7–10 year refresh cycles where the physical layer must outlive two generations of active equipment. At 4 meters, this trunk length matches typical rack-to-rack spacing in hot-aisle/cold-aisle layouts (42U racks on 600mm rails, 1200mm aisle, ~3.5–4.5m center-to-center), and the factory length eliminates the coil-management problem that comes with oversized trunks: no 15-meter trunk stuffed into a 2U cable manager creating bend-radius violations.

Compliance with TIA-568.3-D, ISO/IEC 11801, and ANSI/TIA-942-B ensures this interconnect integrates into mixed-vendor infrastructures without proprietary lock-in. The 12-fiber count aligns with IEEE 802.3ba parallel optics (4 Tx + 4 Rx + 4 spare for 40G, or 10 Tx + 10 Rx + 2 spare for 100G SR10 when used in pairs), and breakout to duplex LC patch cords via MPO-to-LC cassettes provides backward compatibility with legacy 10GBASE-SR equipment during phased migrations. For integrators managing TIA-606-B labeling and as-built documentation requirements, factory serialization and color-coded boots (aqua for OM4 per TIA-598-D) reduce mis-patching errors that cost hours of troubleshooting in live production environments. This trunk is the structured cabling backbone component that gets your fiber infrastructure installed on schedule, within loss budget, and ready for whatever speed the next hardware refresh demands.

Specifications
Product Type: Fiber Optic Interconnect Trunk
Manufacturer Part Number: FRZTP78X001M004
Sub-Brand: Opti-Core®
Fiber Type: OM4 Multimode 50/125µm
Number of Fibers: 12
Connector 1 Type: PanMPO Female
Connector 2 Type: PanMPO Male
Polarity Method: Method A (Straight-through)
Overall Length: 4m (13.1 ft)
Jacket Rating: Plenum (OFNP)
Flammability Standard: UL 910 (Steiner Tunnel)
Application: Data center backbone, telecommunications rooms, MDA-to-HDA interconnect, equipment distribution areas
Bandwidth: 10G to 400m, 40G to 150m, 100G to 100m
Insertion Loss: ≤0.35 dB per mated pair (factory tested)
Standards Compliance: TIA-568.3-D, ISO/IEC 11801, ANSI/TIA-942-B, IEEE 802.3ba
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C
Jacket Color: Aqua (per TIA-598-D)
Category: Pre-terminated Fiber Infrastructure
Cable Category: fiber_optic
Application: Data centers, telecommunications rooms, entrance facilities, and equipment distribution areas requiring pre-terminated fiber infrastructure for rapid deployment.
Connector 1: PanMPO Female
Connector 2: PanMPO Female
Fiber Type: OM4 Multimode (50/125µm)
Flammability Rating: Plenum (OFNP)
Fiber Count: 12
Length Ft: 13.1
Length M: 4
Polarity: Method A
Product Type: Fiber Interconnect
Standards: TIA-568.3-D, ISO/IEC 11801, ANSI/TIA-942-B
Sub Brand: Opti-Core®
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources