Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZTP77Y001F064 OM4 12-Fiber Plenum MPO Trunk Assembly

The Panduit FRZTP77Y001F064 is a 12-fiber OM4 multimode MPO trunk assembly built for high-density structured cabling environments where clean routing, code compliance, and headroom for future bandwidth demands are non-negotiable. At 64 ft, it covers practical rack-to-rack, row-to-row, and equipment-to-distribution-panel runs inside data centers and enterprise network rooms without forcing excess slack into the pathway. If you're building out a fiber optic cable infrastructure designed to stay organized under operational pressure, this is the assembly to evaluate.

Overview

MPO trunk assemblies like the FRZTP77Y001F064 consolidate what would otherwise require twelve individual terminations into a single compact multi-fiber connector — the PANMPO female interface. That reduction in termination count directly improves port density at patch panels and cassettes, which is the real driver behind MPO adoption in switching and storage interconnect architectures. Panduit fiber assemblies are engineered to integrate with the broader Panduit enterprise cabling platform, so if your infrastructure already includes Panduit cassettes, enclosures, or patch panels, this trunk slots in without compatibility questions.

OM4 multimode fiber is the correct grade for short-reach, high-bandwidth links inside the facility — 40GbE and 100GbE applications over duplex or parallel optics, depending on the transceiver type. The fiber construction preserves headroom for future throughput demands without requiring an immediate plant upgrade to single-mode.

Key Features

  • OM4 Multimode Fiber: Supports 40GbE up to 150m and 100GbE up to 100m in parallel optic configurations — practical reach for any intra-facility run, without the cost premium of single-mode glass or the transceiver overhead that comes with it.
  • 12-Fiber MPO Design: Consolidates twelve optical paths into one PANMPO female connector. In high-density switching environments, that means fewer connectors to manage at the panel face, cleaner cable bundles, and faster patching during moves, adds, and changes.
  • PANMPO Female Connector Interface: Compatible with Panduit's enterprise fiber infrastructure — cassettes, enclosures, and modules that accept the PANMPO interface. Buying into a common connector ecosystem reduces the risk of mismatched polarity or undefined insertion loss at the panel.
  • Plenum-Rated Jacket: Qualifies for installation in air-handling spaces without a conduit requirement. For any project where the cable path crosses a plenum ceiling or raised-floor air return, this rating is a compliance requirement — not an upgrade. Skipping it on a plenum run creates a fire-code liability.
  • 64 ft Cable Length: Covers rack-to-rack and row-to-row distances in most standard data center layouts without leaving excess slack that impedes airflow or complicates serviceability. If your run is significantly shorter or longer, verify the length before ordering — trunk assemblies are not field-terminable.
  • Polarity B Configuration: The assembly ships with a defined MPO polarity scheme. Confirm polarity compatibility with your cassettes and modules before deployment — mixing polarity types at a panel can result in crossed transmit/receive paths that are difficult to troubleshoot after installation.
  • High-Density Infrastructure Application: Purpose-built for environments where individual LC or SC patch cords would create unmanageable cable volumes at the panel. Trunk-and-cassette architectures using assemblies like this support cleaner physical layer documentation and faster fault isolation.

Integration and Compatibility

The FRZTP77Y001F064 is designed to integrate with Panduit's structured cabling system, including their fiber cassettes, enclosures, and high-density panels that accept the PANMPO female interface. When deploying in mixed-vendor environments, confirm that the receiving cassette or panel accepts standard MPO/MTP female connectors — many third-party panels are compatible, but verify polarity handling before committing to the installation layout.

OM4 fiber is backward compatible with OM3 transceivers and infrastructure, though at reduced distance ratings. If your switches or storage arrays use standard LC duplex or parallel MPO optics, you'll need the appropriate breakout cassette or harness on the equipment end. For network switch interconnects running 40G SR4 or 100G SR4 optics, an OM4 12-fiber trunk terminated into an 8-fiber MPO cassette with duplex LC breakouts is the standard architecture this cable supports.

When planning cable routes, confirm that plenum-rated cable is required — if the path runs through conduit in a non-plenum space, a riser-rated assembly may serve the same function at lower cost. However, if any segment of the run crosses a plenum air-handling zone, the plenum rating on the FRZTP77Y001F064 is mandatory, not optional. Pair this assembly with a compatible fiber patch panel to complete the high-density termination point.

Frequently Asked Questions

Q: What fiber grade is the FRZTP77Y001F064, and what speeds does it support?

A: The FRZTP77Y001F064 uses OM4 multimode fiber, which supports 40GbE up to 150m and 100GbE up to 100m using parallel optic (MPO) transceivers. It is a strong choice for intra-data-center and enterprise network room interconnects where those distance ranges are sufficient.

Q: Is the FRZTP77Y001F064 compatible with standard MPO/MTP connectors from other vendors?

A: The assembly uses a PANMPO female interface, which is Panduit's MPO-family connector. Many third-party MPO cassettes and panels will physically accept it, but always verify polarity type (this assembly ships in Polarity B) and confirm mating connector gender before installation to avoid transmit/receive path errors.

Q: Does the 64 ft length include any service loop, or is it the usable run distance?

A: The specified 64 ft is the overall cable length. Account for any bend radius allowances and pathway routing in your actual measurement — trunk assemblies cannot be field-terminated or shortened, so measure carefully before ordering.

Q: Why does the jacket rating matter — can I install this in any ceiling or floor space?

A: The plenum rating on the FRZTP77Y001F064 is required specifically for air-handling spaces (plenum ceilings, raised-floor air returns). In non-plenum spaces with conduit, a riser-rated cable would also be code-compliant. Without the plenum rating in a plenum space, the installation fails fire-code requirements regardless of the cable's optical performance.

Q: What does the 12-fiber MPO design mean for my panel space?

A: An MPO connector carries 12 optical fibers in one connector footprint. Compared to six individual LC duplex connections, you terminate one connector instead of twelve fiber ends at the panel — reducing connection points, improving cable management, and speeding up patching during changes.

Q: Can I use this trunk with OM3 infrastructure or transceivers?

A: OM4 fiber is backward compatible with OM3 optics, but at reduced maximum distances. If your transceivers are spec'd for OM3 at a given distance, using OM4 fiber provides margin rather than a penalty. Mixing OM3 and OM4 fiber segments in a single link is not recommended.

James Everett
James Everett

The detail I want integrators to focus on with the FRZTP77Y001F064 is the polarity designation — this assembly ships in Polarity B. That's not a footnote; it's the spec that determines whether your transmit and receive paths are correctly aligned at both ends of the link. Get it wrong and you'll spend diagnostic time tracing a problem that was baked in at installation.

Technical Highlights:

  • OM4 Multimode Fiber: Rated for 40GbE to 150m and 100GbE to 100m in parallel optic configurations — gives you real distance headroom inside most campus or data center footprints without stepping up to single-mode infrastructure.
  • 12-Fiber MPO, PANMPO Female: One connector replaces twelve individual termination points at the panel. In a high-density row with 24 or 48 ports per panel, that's the difference between a manageable cable plant and a termination nightmare during a maintenance window.
  • Plenum Jacket: Mandatory — not optional — for any cable route that crosses air-handling space. The FRZTP77Y001F064's plenum rating satisfies NEC Article 770 requirements for those runs without requiring conduit, which simplifies the physical plant design in buildings with open plenum ceilings.

Deployment Considerations:

  • Trunk assemblies are not field-terminable. Measure your actual routed distance — not the straight-line distance — before ordering. The 64 ft length needs to cover the full pathway including vertical drops, bend radii, and any slack loop at the panel end.
  • Confirm cassette gender and polarity type before the trunk arrives on-site. A Polarity B trunk mated to a Polarity A cassette without an adapter will cross your transmit and receive paths — a problem that tests clean on a continuity check but fails the link test.

This assembly is the right specification for a data center row-to-row interconnect where you're running 40G or 100G switching fabric, the cable path crosses plenum space, and the panel architecture is built on MPO cassettes. It's not the call for a short LC duplex patch between two adjacent switches — that's a different product entirely.

Specifications
Fiber Type: OM4 Multimode
Fiber Count: 12-Fiber
Connector Interface: PANMPO Female
Cable Length: 64 ft
Jacket Rating: Plenum
Q&A
Reviews

Panduit OM4 12-Fiber MPO - FRZTP77Y001F064

$975.08
$577.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support