Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRZTP78Y001F007 OM4 12-Fiber PanMPO Trunk Cable Assembly

Overview

The Panduit FRZTP78Y001F007 is a 7 ft, 12-fiber OM4 multimode trunk assembly built around PanMPO female connectors on both ends — the kind of factory-terminated cable you reach for when a field-built link is too risky and a longer assembly just adds slack you'll fight with for the next three years. At 7 ft, it's designed specifically for short rack-to-rack or equipment-to-panel hops inside dense cabinets where cable management discipline is non-negotiable.

OM4 multimode fiber on 50/125 µm core/cladding geometry means this cable is rated for the short-reach enterprise speeds that data center aggregation and distribution layers actually run — 10GbE, 40GbE, and 100GbE over MPO links in structured Panduit fiber architectures. The aqua jacket is the standard color identifier for OM4, so your team won't have to guess what's plugged in during a 2 a.m. incident response.

Key Features

  • OM4 50/125 µm Multimode Fiber: OM4 supports higher bandwidth-distance products than OM3, which matters when you're running 100GbE over a parallel optic MPO link — even at 7 ft, using the right fiber grade keeps the channel compliant with the headroom your optics expect.
  • 12-Fiber Construction: Twelve fibers in a single MPO connector supports 40GbE (8-fiber used) and 100GbE (12-fiber used) parallel optic deployments without stacking multiple smaller connectors. One cable, one connector, one cable management decision.
  • PanMPO Female Connectors, Both Ends: Factory-terminated by Panduit, these connectors are built to the same tolerances across every unit — eliminating the variability you get from field polishing. Female-to-female configuration is the standard interconnect orientation for cassette-based structured fiber systems.
  • 7 ft Length: Short enough to keep a dense cabinet tidy, long enough to bridge adjacent rack units without stretching. If you're using slack management brackets or pulling cable across a rack aisle, this isn't the cable — but for in-cabinet equipment interconnects, 7 ft is exactly right.
  • Polarity B Configuration: Polarity B is one of the three TIA-568 defined polarities for MPO-based systems. Using it consistently across a structured fiber architecture prevents the mismatched-pair problems that cause hours of troubleshooting when someone grabs the wrong cable at a cable pull.
  • Optimized Insertion Loss: Factory assembly with controlled insertion loss means you're not burning optical budget guessing whether a field termination hit spec. In tightly budgeted links — especially 100G parallel optic channels with limited loss headroom — that consistency is the difference between a link that trains and one that marginalizes.
  • Aqua Jacket: Color-coded per ANSI/TIA standards for OM4 multimode. Speeds up visual inspection and reduces the chance of cross-connecting fiber types during moves, adds, and changes.

Integration & Compatibility

The FRZTP78Y001F007 is built for use within Panduit's structured fiber ecosystem — specifically for equipment-to-cassette and cassette-to-cassette interconnects using PanMPO-based fiber enclosures and patch panels. The PanMPO female connector mates with PanMPO male connectors on Panduit fiber cassettes and adapter panels, making this a direct fit for enterprise network closets and data center distribution rows already built on Panduit infrastructure.

Polarity B configuration aligns with structured cabling designs where the overall link polarity is managed at the cassette or adapter level, not the trunk. Before deploying, confirm the polarity scheme across the entire channel — mixing polarity methods without a channel-level audit is one of the more common sources of silent fiber link failures in MPO-based systems.

For teams sourcing Panduit fiber assemblies as part of a broader fiber optic cable and assembly infrastructure, this trunk slots directly into a Panduit-standardized BOM. If you're evaluating structured cabling solutions for a new build or refresh, a fiber optic assembly buying guide can help size trunk lengths and polarity schemes before committing to cable quantities.

Frequently Asked Questions

Q: What fiber type and grade does the FRZTP78Y001F007 use?

A: It uses OM4 multimode fiber with a 50/125 µm core/cladding geometry. OM4 is rated for higher bandwidth-distance products than OM3 and supports 40GbE and 100GbE parallel optic applications over short enterprise links.

Q: What polarity configuration does this cable use?

A: The FRZTP78Y001F007 is wired in Polarity B. This is one of the three TIA-568 defined MPO polarity methods. Make sure your overall channel polarity scheme is designed around Polarity B before installing — mixing polarities without a full channel audit is a common source of link failures in MPO-based structured cabling.

Q: Can I use this cable for 100GbE connections?

A: Yes, the 12-fiber construction and OM4 grade support 100GbE parallel optic (100G-SR4) links. All 12 fibers are used in a 100G-SR4 configuration, so this is the right count for that application. Confirm your transceiver's loss budget against the cable's insertion loss spec to ensure margin.

Q: What connector type does this cable use and what does it mate with?

A: Both ends use PanMPO female connectors. These are Panduit's MPO-variant connectors designed to mate with PanMPO male connectors found on Panduit fiber cassettes, adapter panels, and active equipment with PanMPO male ports.

Q: Is 7 ft long enough for cross-rack connections?

A: For in-cabinet equipment-to-panel hops and adjacent rack unit connections, 7 ft is the correct length. It is not designed for inter-rack or rack-aisle runs — those applications require longer trunk assemblies. Using an undersized cable for a longer run will put stress on the connectors and degrade insertion loss.

Karl Wilson
Karl Wilson

The detail I keep coming back to on the FRZTP78Y001F007 is the 7 ft length paired with 12-fiber OM4 and factory-terminated PanMPO female connectors — that combination isn't accidental. Panduit engineered this assembly for the specific scenario where you're connecting active equipment or a switch faceplate directly to a fiber cassette inside the same cabinet, and you need repeatable insertion loss without introducing a field termination variable into a 100G link budget.

Technical Highlights:

  • OM4 50/125 µm Grade: OM4 supports longer effective modal bandwidth than OM3, which gives 100G-SR4 optics more headroom on even a short 7 ft link — useful when your transceiver margin is already tight from connector count on a longer channel.
  • 12-Fiber MPO Configuration: Supports 40G-SR4 (8 fibers active) and 100G-SR4 (12 fibers active) in a single connector, eliminating the need to stack duplex LC cables across a high-density faceplate when you're aggregating uplinks.
  • Polarity B, Factory-Wired: Polarity is set at the factory and consistent across every unit. In a structured Panduit cassette architecture, Polarity B trunks work with Polarity A cassettes to produce a correct end-to-end channel — but that only holds if the whole system is designed around the same scheme from the start.

Deployment Considerations:

  • Confirm polarity scheme across the entire channel before ordering quantity — a mix of Polarity A and Polarity B trunks in the same run will produce crossed pairs and a dead link with no obvious visual cue.
  • PanMPO female-to-female is the right orientation for cassette-to-equipment interconnects, but if your cassette uses a male PanMPO trunk port (as some older Panduit enclosures do), you'll need an adapter or a different assembly — verify the cassette port gender before the cable ships.

This cable is the right pick for enterprise network closets and data center ToR (top-of-rack) to EoR (end-of-row) distribution rows where the active equipment is in the same cabinet as the patch point, the fiber count is already defined at 12, and field termination is not an acceptable variable in your optical budget.

Specifications
Fiber Type: OM4 Multimode
Core Cladding Size: 50/125 µm
Fiber Count: 12-Fiber
Cable Length: 7 ft
Connector Type: PanMPO Female
Jacket Color: Aqua
Q&A
Reviews
Have Questions?

Panduit OM4 12-FI P FE-MA POLB OIL 7FT PK1 - FRZTP78Y001F007

$660.44
$393.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources