Altronix OCC ALERT SY 2DR/ENC/24VAC IN - TEMPOA2
Dedicated enclosure designed to house and power access control systems for up to two doors
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix TEMPOA2XV is a self-contained occupancy alert control system designed for two-door monitoring applications that require integrated strobe signaling, panic response, and local power distribution — all in a single pre-wired enclosure. Running on 220VAC/60Hz at just 0.25A draw, it is suited for international installations and facilities where 220V branch circuits are the standard. If you are managing occupancy compliance in retail environments, controlled-access corridors, or secure rooms where you need door-state awareness plus immediate visual alerting, the TEMPOA2XV packages the control logic and power supply into one enclosure rather than requiring you to piece together separate components.
The unit monitors two doors via dedicated sensor inputs and pairs each door with its own strobe trigger input and switched strobe power output — so each entrance gets its own independent alert loop. Four additional auxiliary DC power outputs extend capacity for supplemental devices such as magnetic locks, card readers, or door controllers without requiring a separate power supply in the same cabinet.
The TEMPOA2XV is designed to integrate with standard door contact sensors (magnetic contacts, door position switches) wired to its sensor inputs, and with conventional strobe/visual alert devices wired to its switched power outputs. The dual-voltage DC output accommodates the broadest range of access control peripherals. Panic inputs accept dry-contact signals from standard duress buttons or pull stations. Because the system operates at 220VAC, verify that your building's branch circuit and any conduit runs are correctly rated before installation — the 0.25A draw is light, but the voltage class determines conduit and wire gauge requirements under NEC or applicable local code. Consult your Altronix product line documentation for terminal wiring diagrams and input/output specifications before roughing in.
For deployments where occupancy control integrates with broader access control systems, the TEMPOA2XV's panic and door sensor inputs can be driven by controller dry-contact outputs, effectively making it a local alert and power distribution satellite for a larger system architecture. Pair this unit with appropriate access control power supplies when additional current capacity is needed beyond the onboard 30W output, or with door controllers to manage the access decision layer above this unit's signaling function. For planning the power distribution side of a multi-door deployment, review a power planning guide to size auxiliary loads accurately.
Q: What is the input voltage requirement for the TEMPOA2XV?
A: The TEMPOA2XV requires 220VAC at 60Hz, drawing 0.25A. It is not designed for 120VAC input — verify your branch circuit voltage before installation.
Q: Can the TEMPOA2XV power 24V magnetic locks directly?
A: Yes. The onboard power supply is selectable between 12VDC at 2.5A and 24VDC at 1.25A (30W total). A 24V magnetic lock drawing under 1.25A can be powered directly from the enclosure. For locks with higher inrush or holding current, size a separate supply accordingly.
Q: How many doors can the TEMPOA2XV monitor?
A: The TEMPOA2XV supports two door sensor inputs, two strobe trigger inputs, and two switched strobe power outputs — one complete alert loop per door. It is a two-door system by design.
Q: Does the TEMPOA2XV include panic input capability?
A: Yes. The unit includes two panic trigger inputs that accept dry-contact signals from duress buttons or emergency pull stations, enabling strobe activation as a visual distress signal without a separate relay module.
Q: Is the TEMPOA2XV suitable for outdoor or unheated enclosure installation?
A: No. The specified operating temperature range is 0°C to 49°C, which covers conditioned interior environments. It is not rated for outdoor installation or unheated spaces where temperatures fall below freezing.
Q: What are the physical dimensions of the enclosure?
A: The enclosure measures 8.5 inches wide by 7.5 inches tall by 3.5 inches deep — compact enough for electrical closets, server rooms, or above-ceiling mounting locations.

The TEMPOA2XV is one of those units that earns its place on a job when the alternative is mounting four separate components — a transformer, a control board, a power supply, and a relay module — in a closet with limited real estate. At 220VAC input and 30W DC output, it is specifically sized for international builds and 220V-standard facilities where sourcing a 120V-native Altronix variant would mean adding a step-down transformer anyway.
Technical Highlights:
Deployment Considerations:
This unit is the right call for a two-door occupancy alerting deployment in a conditioned interior space — retail backroom entries, pharmacy dispensary doors, or controlled-access server room vestibules — where the installer needs consolidated power distribution and per-door strobe signaling without building a custom panel from discrete components.