Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit NKFPL48 NetKey 48-Port Front-Access Modular Patch Panel

The Panduit NKFPL48 is a 48-port front-access modular patch panel from the Panduit NetKey copper cabling line — built for structured cabling deployments where field-replaceable Keystone modules and clean front-panel access matter more than a fixed-port factory-terminated design. At 2RU in a 19-inch form factor, it fits standard network patch panels and telecom racks without modification, and the modular architecture means you can mix Cat5e, Cat6, or Cat6A modules in a single panel as your cabling plant evolves.

Overview

Structured cabling infrastructure lives for a decade or longer — the flexibility to reconfigure individual ports without replacing the entire panel is a real operational advantage in enterprise IDFs, data center distribution frames, and commercial building risers. The NKFPL48 achieves this by accepting any standard 48 NetKey Keystone modules in a flat, front-access chassis. Labels and port covers ship with the panel, keeping your documentation organized from day one. The black CRS (cold-rolled steel) chassis is RoHS-compliant, which satisfies the environmental compliance requirements common in EU-adjacent procurement contracts and LEED-certified facilities.

Key Features

  • 48-Port Modular Capacity in 2RU: Forty-eight Keystone module slots in a 3.47-inch (88.1 mm) chassis height means you get a full 48-port copper termination block without burning a third rack unit. High-density MDFs and IDFs with tight space budgets will appreciate the 2RU discipline — that's 24 ports per RU, which competes with fixed high-density panels without sacrificing field serviceability.
  • Front-Access Architecture: All 48 ports face forward, so moves, adds, and changes don't require you to swing the panel out or work blind behind a cable ladder. In live environments where downtime is unacceptable, being able to re-terminate or swap a module from the front without disturbing neighboring equipment is a meaningful workflow benefit.
  • Field-Replaceable Keystone Modules: The chassis accepts NetKey Keystone modules — you populate it at installation with whatever category rating your runs demand (Cat5e, Cat6, Cat6A unshielded) and replace individual ports without touching adjacent ports. A single failed port doesn't force a panel swap, which matters in warranty-sensitive commercial installs.
  • 19-Inch and 23-Inch Rack Compatibility: The 19-inch (482.6 mm) panel width mounts in standard EIA-310 19-inch racks and cabinets as well as legacy 23-inch telco frames. That dual compatibility means the NKFPL48 works across mixed rack environments without adapter hardware — useful in older facilities with installed telco infrastructure alongside modern IT racks.
  • CRS Steel Construction: Cold-rolled steel gives the chassis the rigidity to handle repeated cable pulls and module swaps over years of use without warping or port misalignment. This isn't decorative sheet metal — it's the same material class used in commercial-grade rack enclosures.
  • Unshielded Application Targeting: The NKFPL48 is specified for unshielded (UTP) cabling runs, which covers the majority of enterprise horizontal and backbone copper deployments. If your environment requires shielded (STP/FTP) terminations for EMI-sensitive zones — near heavy industrial equipment or in healthcare imaging suites — evaluate Panduit's shielded panel variants instead.
  • Includes Labels and Port Covers: Blank port covers and identification labels ship with the panel. Covers prevent dust ingress on unpopulated ports (a frequent source of contact degradation in high-dust environments like warehouses or light industrial spaces), and pre-cut labels keep port documentation consistent with whatever labeling standard your site uses.
  • RoHS Compliance: The NKFPL48 meets RoHS (Restriction of Hazardous Substances) requirements — a procurement checkbox for EU-market projects, LEED documentation packages, and any enterprise IT policy that mandates environmental materials standards across installed infrastructure.

Integration & Compatibility

The NKFPL48 is designed for structured copper cabling infrastructure and integrates directly with any Panduit NetKey Keystone jack modules. Because it targets unshielded applications, it pairs naturally with Cat5e, Cat6, and Cat6A UTP jack modules — you select the module category at installation to match your horizontal run ratings. The panel mounts in standard 19-inch EIA-310 open-frame racks and enclosed cabinets, as well as 23-inch telco-style frames. Downstream, patch cords from the panel connect to network switches or other active equipment in the rack. Port count of 48 aligns with 48-port switch configurations, enabling a clean 1:1 patch panel to switch port mapping that simplifies cable management and moves/adds/changes.

The flat, front-access design works with standard horizontal cable management accessories — 1U or 2U managers mounted directly above or below the panel keep patch cord slack contained without requiring custom brackets.

Frequently Asked Questions

Q: What Keystone modules are compatible with the NKFPL48?

A: The NKFPL48 accepts NetKey Keystone jack modules for unshielded (UTP) copper cabling applications. It accommodates 48 modules. Specific compatible module part numbers should be confirmed against Panduit's NetKey product line documentation to match your required cable category (Cat5e, Cat6, Cat6A).

Q: How many rack units does the NKFPL48 occupy?

A: The NKFPL48 occupies 2RU. Its overall height is 3.47 inches (88.1 mm), which fills two standard rack unit slots in an EIA-310 rack.

Q: Does the NKFPL48 support shielded (STP/FTP) cabling?

A: No. The NKFPL48 is specified for unshielded (UTP) cabling applications. For shielded copper terminations, Panduit offers separate shielded panel variants in the NetKey line.

Q: Is the NKFPL48 RoHS compliant?

A: Yes. The NKFPL48 meets RoHS (Restriction of Hazardous Substances) compatibility requirements, making it suitable for projects with EU environmental compliance mandates or enterprise environmental procurement policies.

Q: Can the NKFPL48 mount in a 23-inch rack?

A: Yes. The panel is compatible with both standard 19-inch (482.6 mm) EIA racks and cabinets and legacy 23-inch telco frames, eliminating the need for adapter hardware in mixed-rack environments.

Q: What color is the NKFPL48 and does it include labeling accessories?

A: The NKFPL48 is black. It ships with identification labels and port covers included for documentation and dust protection on unpopulated ports.

James Everett
James Everett

The NKFPL48 is a panel I recommend when a project is planning for longevity — specifically, the 48-port modular Keystone architecture means the 3.47-inch (2RU) chassis can be re-populated with higher-category modules years after initial installation without pulling the panel. That's a real cost avoidance argument in enterprise cabling refreshes where labor is the dominant line item.

Technical Highlights:

  • 48 Ports / 2RU Density: At 3.47 inches tall, you're hitting 24 ports per rack unit — comparable to fixed high-density panels but with per-port replaceability. In a 42RU cabinet you could theoretically run 1,008 copper terminations from modular panels alone, though cable management headroom typically caps practical density lower.
  • CRS Steel Chassis: Cold-rolled steel resists the flex and port-skew problems that show up in lighter-gauge aluminum chassis after repeated module pulls over years of MAC work. In high-churn environments like university dorms or co-working build-outs, chassis rigidity is underrated.
  • Dual 19"/23" Compatibility: The 482.6 mm width fits EIA-310 racks natively; the 23-inch compatibility is a legitimate advantage in telco closets and older campus buildings where you can't justify replacing the entire rack infrastructure just to install a modern panel.

Deployment Considerations:

  • The NKFPL48 ships as an empty chassis — Keystone modules are ordered separately. Budget module cost and count (48 per panel) into your BOM from the start; it's a common quoting oversight that inflates field purchase orders.
  • This panel is UTP-only. If even a portion of your runs require shielding — near VFDs, in healthcare imaging, or in industrial control environments — do not mix unshielded modules into a shielded-spec run. Order the correct shielded panel variant for those zones.

For a greenfield enterprise IDF build or a structured cabling upgrade in a commercial office where the cabling plant will be in service for 10-plus years, the NKFPL48's modular architecture justifies the slight premium over fixed-port panels — the ability to swap a single failed Cat6 jack without a panel replacement pays back quickly in a 200-plus-drop installation.

Specifications
Sub Brand: NetKey®
Color: Schwarz
Material: CRS
Height In: 3.47
Height Mm: 88.1
Width In: 19
Width Mm: 482.6
Product Type: Frontzugangs-Patchpanel
Carton Qty: 10
Package Qty: 1
Standards: RoHS-kompatibel
Upc: 61305678653
Cable Category: copper-systems
Type: Frontzugangs-Patchpanel
Q&A
Reviews
Have Questions?

Panduit NK Modular Patch Panel FC PLT WPK1MOQ10

$101.04
$65.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support