Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL48N12-24-B-AF00 26U NEMA 12 Wall-Mount Enclosure

Overview

The Vertiv GL48N12-24-B-AF00 is a 26U wall-mount enclosure in a NEMA 12-rated steel cabinet measuring 48 inches tall by 24 inches deep. Designed for light industrial and commercial equipment rooms where floor space is at a premium, this enclosure puts structured cabling, small switches, patch panels, and edge computing gear on the wall rather than consuming rack footprint. The GL48N12-24-B-AF00 ships with an integrated fan and filter airflow path — keeping active equipment running without an external cooling unit in most ambient environments — while also accepting optional air conditioning units rated at 1,000, 1,300, or 2,200 BTU when the heat load demands it.

If you are evaluating the Vertiv enclosure line for a server room, IDF closet, or surveillance equipment room, this unit sits in the middle of the GL family height range: 12U (24 inches), 19U (36 inches), and the 26U (48 inches) offered here. That makes it the practical ceiling for wall-mount deployments where structural loading permits — enough rack units to consolidate a full edge stack without moving to a freestanding floor-standing network enclosure.

Key Features

  • 26U capacity in a wall-mount footprint: 48 inches of usable height installs flush to the wall, freeing the floor entirely. For IDF closets, server alcoves, or surveillance equipment rooms that cannot accommodate a full floor cabinet, this is the maximum rack unit count available in the wall-mount format — enough for a PoE switch, patch panels, a small NVR, and an uninterruptible power supply in a single enclosure.
  • NEMA 12 enclosure rating: NEMA 12 seals against dust, dripping water, and light splashing — the right protection level for light manufacturing floors, mechanical rooms, and loading dock areas where open frames and basic enclosures fail. It is not rated for hose-directed water or outdoor use, so deploy accordingly.
  • 24-inch interior depth: Accommodates standard 1U switches, NVRs, and rackmount appliances without shelf adapters. Shallow 14- to 17-inch equipment fits with cable management to spare; deeper servers or UPS units should be measured against the 24-inch interior before ordering.
  • Integrated fan/filter airflow standard: The included fan and filter assembly moves heat out of the enclosure passively without requiring an accessory purchase. For light equipment loads in conditioned spaces, this is typically sufficient — and it keeps the per-rack cooling cost at zero.
  • Optional AC cooling to 2,200 BTU: When heat load from high-density PoE switches, NVRs with multiple drives, or dense patch environments exceeds what the fan can handle, the enclosure accepts optional air conditioning units at three capacities: 1,000 BTU, 1,300 BTU, or 2,200 BTU. Selecting among them is straightforward — add up the watts dissipated by equipment inside, convert (1W ≈ 3.41 BTU/hr), and size to the next tier up with headroom. See the rack cooling solutions category for compatible AC units.
  • GL family compatibility: The GL48N12-24-B-AF00 shares the Vertiv GL enclosure mounting pattern and accessory ecosystem, meaning blanking panels, PDU mounting channels, and cable management accessories specified for the GL family install without modification — a practical advantage when standardizing across multiple closets.
  • Multiple depth option available: The GL family offers both 24-inch and 30-inch depth configurations. If your equipment inventory runs deeper — think 2U rack-mount UPS units or extended-depth storage appliances — evaluate the 30-inch variant before committing. Mixing depths across closets in a single deployment adds unnecessary spare-parts complexity.

Integration and Compatibility

This enclosure is compatible with standard 19-inch rackmount equipment. The NEMA 12 rating and optional UPS and power distribution accessories make it a natural fit for edge deployments in light industrial environments — surveillance NVRs, access control panels, small managed switches, and structured cabling consolidation points. When specifying for a security system installation, confirm that the combined wattage of the NVR, PoE switch, and any other active equipment stays within the thermal envelope the fan/filter can manage, or plan for the optional AC unit from the outset rather than retrofitting later. The wall-mount form factor also simplifies cable entry planning: conduit knockouts are standard on GL-family enclosures, which matters in environments where cable management is code-governed.

Frequently Asked Questions

Q: What is the rack unit capacity of the GL48N12-24-B-AF00?

A: The GL48N12-24-B-AF00 provides 26U of usable rack space in a 48-inch-tall wall-mount cabinet. The GL family also includes 12U (24-inch) and 19U (36-inch) height options if your equipment count is lower.

Q: Does the GL48N12-24-B-AF00 include cooling, or is it sold separately?

A: The enclosure ships with an integrated fan and filter for passive airflow. Optional air conditioning units rated at 1,000 BTU, 1,300 BTU, or 2,200 BTU are available as accessories when the heat load from installed equipment exceeds what the fan alone can handle.

Q: What does the NEMA 12 rating mean for this enclosure?

A: NEMA 12 means the cabinet is sealed against dust ingress and dripping or splashing water. It is appropriate for light manufacturing, mechanical rooms, and loading dock environments. It is not rated for outdoor use or hose-directed water — those applications require NEMA 3R or higher.

Q: What interior depth does the GL48N12-24-B-AF00 provide?

A: The standard configuration provides 24 inches of interior depth, which accommodates most 1U rackmount switches, NVRs, patch panels, and appliances. A 30-inch-depth variant is available in the GL family for deeper equipment.

Q: Can this enclosure be wall-mounted in an IDF closet for a surveillance system?

A: Yes. The wall-mount design is well-suited for IDF closets and surveillance equipment rooms where floor space is limited. Confirm that the wall structure can support the loaded weight of the enclosure and installed equipment before mounting, and verify cable entry knockout placement against your conduit routing plan.

Ted Perry
Ted Perry

The GL48N12-24-B-AF00 is a 26U NEMA 12 wall-mount enclosure that I reach for when a project needs to consolidate edge gear in a light industrial space and floor space simply is not available. The built-in fan and filter is the spec that changes the install economics most: no separate cooling accessory to price, source, and mount on day one — just hang the cabinet, install equipment, and verify exhaust temperature before signing off.

Technical Highlights:

  • 26U / 48-inch height: Enough rack units to house a managed PoE switch, multi-channel NVR, patch panel, and small UPS in a single wall-mounted footprint — without touching the floor.
  • Fan/filter standard + AC to 2,200 BTU optional: The included fan handles light equipment loads; the 2,200 BTU AC option gives you room to grow into higher-density configurations without swapping the enclosure.
  • 24-inch interior depth: Fits standard 1U rackmount appliances cleanly. At 24 inches you are working within the GL48N12-24-B-AF00's stated depth — measure any extended-depth UPS or storage unit against this before the equipment ships.

Deployment Considerations:

  • NEMA 12 is the right rating for mechanical rooms and light manufacturing floors, but it is not a substitute for NEMA 3R in any outdoor or wash-down application — verify the deployment environment before specifying.
  • If the equipment list includes high-density PoE switches or NVRs with multiple spinning drives, calculate the thermal load (watts × 3.41 = BTU/hr) before the install date and order the appropriate optional AC unit in the same PO — retrofitting cooling after equipment is live is avoidable friction.

This enclosure fits best in a surveillance or access control IDF closet where you need NEMA 12 ingress protection, genuine 26U capacity on the wall, and a thermal upgrade path already built into the platform — without committing to a full floor cabinet on day one.

Specifications
Height: 24" (12U)36" (19U)48" (26U)
Depth: 24"30"
Airflow: Fan/Filter1000 BTU AC1300 BTU AC2200 BTU ACAccepts Optional Fan/FilterAccepts Optional ACClear
freight: 565.40
Q&A
Reviews

Vertiv NEMA 12K WM 26UX24X24 Fangray - GL48N12-24-B-AF00

$3,625.00
$2,629.99

RELATED PRODUCTS

Save $1,161.01
Vertiv NEMA 12K WM 26UX24X24 Gray - GL48N12-24-B-AFFF
Add to Cart The item has been added

Vertiv GL48N12-24-B-AFFF

Vertiv NEMA 12K WM 26UX24X24 Gray - GL48N12-24-B-AFFF

26U, 24-inch deep NEMA 12K rated rack enclosure designed to house sensitive IT and surveillance equipment in environments requiring protection

    Usually Ships in 2-3 Weeks Free shipping over $499
    $4,121.00 $2,959.99 Save $1,161.01
    The item has been added Add to quote
    $4,121.00 $2,959.99 Save $1,161.01
    Save $1,161.01 Add to cart Add to quote
    Save $3,152.01
    Image coming soon
    Add to Cart The item has been added

    Vertiv GL48N12-30-B-AC22

    Vertiv NEMA 12K WM 26UX24X30 Fangray - GL48N12-30-B-AC22

    48-inch tall, 26U NEMA 12K wall-mount enclosure designed to house sensitive IT and networking equipment in environments where dust and falling dirt

      Usually Ships in 2-3 Weeks Free shipping over $499
      $10,275.00 $7,122.99 Save $3,152.01
      The item has been added Add to quote
      $10,275.00 $7,122.99 Save $3,152.01
      Save $3,152.01 Add to cart Add to quote

      System Design, Deployment & Technical Support

      Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

      Fixed scope • Fixed price

      System Design Assistance

      • Get help validating product compatibility
      • Coverage requirements
      • Storage planning and deployment architecture before you buy.
      Request Design Help

      Deployment & Configuration Support

      • Access fixed-scope support for rollout planning
      • User setup guidance
      • Migration and system standardization across single-site or multi-site deployments
      View Support Services

      Guides, Tools & Calculators

      • PoE requirements
      • Storage retention
      • Camera selection and deployment methodology
      Open Technical Resources