Vertiv MU03E4W1-30L133-3PS56B4B10-S - UI30004L
Dedicated power supply unit designed to provide stable and reliable power for specific Vertiv rack-based infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv UI30001L is a monitored, unit-level, EC-upgradeable vertical power distribution unit rated at 30/32A on a 230/400V WYE three-phase input. At 87 inches tall and purpose-built for vertical rack installation, it fits flush alongside equipment in standard data center and server room cabinets without consuming precious rack-unit space. If your deployment requires outlet-level visibility into power consumption — not just aggregate PDU draw — the UI30001L's unit-level monitoring gives operations teams the granularity to detect failing or overloaded devices before they cause an outage. The EC-upgradeable architecture also means you're not locked into a fixed feature set: intelligence can be expanded as your monitoring requirements evolve, protecting the capital investment. Browse the full Vertiv power distribution catalog to see complementary PDU configurations.
The UI30001L is designed for integration with Vertiv's broader power distribution and monitoring ecosystem. The EC-upgradeable slot supports Vertiv's Geist monitoring modules, enabling SNMP, Modbus, or web-based management depending on the module installed. For data center managers running DCIM platforms, the unit-level metering data integrates with most major DCIM tools via standard protocols once the appropriate EC module is provisioned. Review your power planning requirements and confirm the branch circuit supports 30/32A three-phase before commissioning. International deployments should verify local wiring standards match the WYE 400V configuration — this is not a split-phase North American unit.
Q: What input voltage and phase configuration does the UI30001L require?
A: The UI30001L requires a 230/400V WYE three-phase input, rated at 30/32A. This is an international three-phase configuration — not compatible with standard North American single-phase or split-phase 208V circuits without appropriate upstream transformer infrastructure.
Q: What does "EC-upgradeable" mean on the UI30001L?
A: EC stands for Environmental Controller. The UI30001L ships with a base monitoring capability, and the EC module slot accepts Vertiv Geist upgradeable controllers that add features such as SNMP management, outlet-level switching, and environmental sensor ports — without replacing the physical PDU chassis.
Q: How is the UI30001L mounted in a rack?
A: The UI30001L is a vertical PDU designed to mount in the vertical channel of a standard equipment rack. At 87 inches long, it is sized for a full-height 42U cabinet and does not consume any rack units, leaving all 42U available for active equipment.
Q: Does the UI30001L support outlet-level power monitoring?
A: Yes. The "unit-level" designation indicates per-outlet or per-outlet-group monitoring capability, providing granular power consumption data rather than just total PDU input draw. This is a key differentiator versus inlet-only monitored PDUs.
Q: What is the physical weight of the UI30001L?
A: The UI30001L weighs 49 lbs. Plan for a two-person installation, particularly when mounting in a populated rack where maneuvering space is limited.

The UI30001L sits in a specific niche: international three-phase deployments where you need outlet-level power visibility but don't want to burn rack space on a horizontal PDU. The 30/32A 230/400V WYE rating positions it squarely for EU and APAC data center builds — if you're running North American 208V three-phase, this is not your unit.
Technical Highlights:
Deployment Considerations:
The UI30001L is the right call for international colocation builds and enterprise data halls running 400V three-phase power where outlet-level accountability and future EC expandability are both on the requirements list.