APC by Schneider Electric MGE Galaxy 3500 10KVA 208V with 2 Battery Modules Start-up - G35T10KF2B2S

APC by Schneider Electric G35T10KF2B2S MGE Galaxy 3500 10KVA Rackmount UPSThe APC by Schneider Electric G35T10KF2B2S is a 10KVA / 8000W three-phase-in…

$14,045.00 $9,534.99 SAVE $4510
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric MGE Galaxy 3500 10KVA 208V with 2 Battery Modules Start-up - G35T10KF2B2S

$14,045.00
$9,534.99

Overview

SKU: G35T10KF2B2S
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric G35T10KF2B2S MGE Galaxy 3500 10KVA Rackmount UPS

The APC by Schneider Electric G35T10KF2B2S is a 10KVA / 8000W three-phase-input, single-phase-output online double-conversion UPS designed for mid-size data centers, server rooms, and critical infrastructure environments running 208V distribution. Shipping with two battery modules and a 5x8 factory start-up service included, this unit is spec'd for deployments where the cost of downtime exceeds the cost of proper power protection — network operations centers, healthcare IT closets, financial trading infrastructure, and dense virtualization stacks.

Overview

The Galaxy 3500 platform sits in the MGE lineage — APC's commercial and industrial UPS line — distinguished from the SMX/SMT consumer-adjacent series by its true online double-conversion topology. That means the load runs off inverted DC power at all times, not utility power with a transfer switch: utility fluctuations, sags, surges, and waveform distortion are isolated completely before they reach connected equipment. The G35T10KF2B2S ships factory-new with the start-up service bundled, reducing commissioning friction for enterprise procurement teams that need a verifiable install record.

Key Features

  • 10KVA / 8000W Output Capacity: At 0.8 power factor, this unit supports a realistic mix of server, storage, and networking loads. A 10KVA nameplate with an 8kW real-power rating is the honest number to size against — plan your load budget on watts, not VA, to avoid overloading a correctly-sized UPS.
  • 93% Efficiency: Online double-conversion systems typically run 88–92% efficient; hitting 93% at this capacity reduces heat load in the rack environment and lowers operating cost. On a unit drawing this much power continuously, a 1–2% efficiency gain translates to meaningful annual energy savings in a 24/7 facility.
  • Output Voltage THD ≤4%: Total harmonic distortion on the output is held to 4% or below, which matters for sensitive analog and mixed-signal equipment sharing the same UPS. High THD from a poorly regulated inverter can corrupt timing-sensitive loads — 4% THD keeps you well inside most equipment manufacturers' tolerance specs.
  • Sealed Lead Acid (VRLA) Battery Technology with 5-Hour Recharge: VRLA batteries require no maintenance, no watering, and no venting considerations beyond standard equipment room airflow. The 5-hour recharge time to full capacity means that after a full discharge event, the system is back to protected status well within a single business shift — relevant for facilities that see multiple grid events per month.
  • 51.3 dB Noise Level: At 51.3 dB, this unit is measurably quieter than many competing online UPS platforms at this capacity. Still audible in an open office or small IT closet — plan accordingly — but appropriate for a dedicated server room or data hall without additional acoustic treatment.
  • Audible Alarm System: On-board audible alarms provide local notification of fault conditions without requiring a monitoring console to be actively watched. Useful during off-hours when NOC staffing is light.
  • Serial Port Connectivity: One serial port enables direct integration with building management systems, SNMP cards, or legacy monitoring infrastructure. For network-managed shutdown, pair with an APC AP9630 or AP9631 network management card (sold separately).
  • Rackmount Form Factor: Designed for standard 19-inch rack deployment. Verify rack unit height and weight capacity before installation — VRLA battery modules at this scale are heavy; confirm floor load ratings in raised-floor environments.
  • Operating Range 0–40°C / 0–95% RH: Rated for standard equipment room conditions. The 0–40°C operating window is industry-standard for data center environments; operating near the upper boundary will accelerate battery aging — target room temperature below 25°C for maximum battery service life.
  • Operating Altitude Up to 999.9m: Designed for sea-level to near-1,000m deployments. If your facility sits above 1,000m (Denver, for example, sits at ~1,609m), derate capacity accordingly and confirm with APC's altitude derating tables before sizing the load.

Integration & Compatibility

The G35T10KF2B2S includes one AC outlet and one serial port. For full network visibility and graceful server shutdown orchestration, an optional network management card is required — the serial port alone does not provide SNMP or Modbus TCP. The Galaxy 3500 platform supports APC's PowerChute Network Shutdown software for VMware, Hyper-V, and bare-metal server environments. Confirm NMC card compatibility with current Galaxy 3500 firmware before ordering separately. The 208V output matches standard North American three-phase branch circuit infrastructure; verify your PDU or load equipment accepts 208V single-phase input before deployment.

Frequently Asked Questions

Q: What is the real power output of the G35T10KF2B2S in watts?

A: The G35T10KF2B2S delivers 8,000W (8kW) of real power at a 0.8 power factor. Size your connected load budget in watts, not VA, to avoid overloading the unit.

Q: How long does it take to recharge the batteries after a full discharge?

A: Battery recharge time is 5 hours to full capacity from a fully discharged state under normal operating conditions.

Q: Does the G35T10KF2B2S include a network management card?

A: No. The unit ships with one serial port for direct connection but does not include a network management card. An optional NMC (such as an APC AP9630 or AP9631) must be purchased separately for SNMP monitoring and network-based graceful shutdown.

Q: What battery technology does this UPS use, and does it require maintenance?

A: The G35T10KF2B2S uses Sealed Lead Acid (VRLA) batteries. VRLA batteries are valve-regulated and maintenance-free — no watering, no electrolyte checks, and no special venting beyond standard equipment room airflow.

Q: Can this unit operate at high altitude locations like Denver?

A: The rated operating altitude is 0 to 999.9m (approximately 3,280 ft). Facilities above that elevation — including Denver at roughly 1,609m — should consult APC's altitude derating guidance before deploying at full rated load.

Q: What output voltage distortion can I expect from the G35T10KF2B2S?

A: Output voltage Total Harmonic Distortion (THD) is 4% or less, keeping connected loads well within the tolerance specs of most commercial and enterprise equipment.

Jerry Tildsen
Jerry Tildsen

The G35T10KF2B2S is one of the more honest configurations in the Galaxy 3500 line — 10KVA nameplate, 8kW real power, two battery modules in the box, and factory start-up included. The 93% efficiency rating is the number I'd lead with in any procurement conversation at this capacity: at 8kW continuous draw, that's roughly 600W less heat dumped into your equipment room compared to a 90% efficient competitor, which has real implications for CRAC unit sizing and PUE targets in dense deployments.

Technical Highlights:

  • 93% Efficiency: Reduces heat load and operating costs at 24/7 continuous draw — meaningful in any facility where power and cooling costs are metered separately.
  • 4% Output THD: Held to 4% total harmonic distortion on the output side, protecting timing-sensitive mixed loads from inverter-generated waveform artifacts — a real concern in medical imaging or financial trading environments.
  • 5-Hour Battery Recharge: Full VRLA recharge in 5 hours means you're back to fully protected status within a single shift after a complete discharge event, rather than waiting overnight.

Deployment Considerations:

  • The 0–999.9m altitude ceiling is a hard spec boundary — high-altitude facilities must apply APC's derating tables before sizing the load at full 8kW. Don't skip this step if you're above 3,000 ft elevation.
  • One AC outlet and one serial port ship standard — network SNMP management requires a separately purchased NMC card. Budget for it upfront; retrofitting after commissioning is avoidable friction.

This configuration fits best in a mid-size enterprise server room or co-location cage where the start-up service inclusion simplifies procurement compliance documentation and the dual battery modules provide meaningful runtime headroom for a 4–6kW production load — the kind of deployment where an unplanned reboot costs more than the UPS itself.

Specifications
Output power capacity: 10 kVA
Output power: 8000 W
Efficiency: 93%
Output voltage Total Harmonic Distortion (THD: 4%
Noise level: 51.3 dB
Audible alarm(s: Yes
AC outlets quantity: 1 AC outlet(s)
Serial ports quantity: 1
Battery technology: Sealed Lead Acid (VRLA)
Battery recharge time: 5 h
Form factor: Rackmount
Product colour: Silver
Operating temperature (T-T: 0 - 40 °C
Storage temperature (T-T: -15 - 45 °C
Operating relative humidity (H-H: 0 - 95%
Storage relative humidity (H-H: 0 - 95%
Operating altitude: 0 - 999.9 m
Non-operating altitude: 0 - 15000 m
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources