Panduit LPCB02-X 4' C20-C19 Dual-Lock Power Cord Red
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Overview
No Bots, Just Experts
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
Panduit LPCB02-X SmartZone Dual-Locking Power Cord
The Panduit LPCB02-X is a 4-foot dual-locking IEC C20 to C19 power cord engineered for high-density rack environments where accidental disconnection during maintenance, cable management, or hot-aisle work can take critical infrastructure offline. Part of Panduit's SmartZone ecosystem, this cord pairs C20 inlet plugs with C19 outlet receptacles—both ends featuring mechanical locking tabs that require deliberate release before removal. The 1.2-meter length is optimized for intra-rack and adjacent-rack PDU-to-server runs in 42U cabinets, and the red jacket provides instant visual identification for phase labeling, circuit segmentation, or color-coded power domains in multi-tenant datacenters. Sold as a 10-pack, the LPCB02-X is UL, CE, and EAC recognized, meeting North American, European, and Eurasian compliance requirements for mission-critical IT loads.
Key Features
- Dual locking connectors—both C20 plug and C19 receptacle feature mechanical retention tabs preventing accidental disconnection during rack service or cable bundling
- IEC C20 to C19 configuration supports up to 16A at 250V (per IEC 60320 C19/C20 rating), compatible with high-wattage servers, blade chassis, and redundant PSU installations
- 4-foot (1.2m) length purpose-built for vertical PDU-to-equipment runs in standard 19" racks and intra-row connections in hot-aisle/cold-aisle layouts
- Red jacket for immediate visual circuit identification—critical in environments using color-coded A/B power feeds, phase rotation marking, or segregated UPS/generator circuits
- High temperature rating withstands sustained heat exposure in densely populated racks and above-plenum routing near high-TDP compute nodes
- 10-pack quantity reduces per-cable cost for datacenter build-outs, refresh projects, or standardized sparing inventory
- UL, CE, and EAC recognized—meets regulatory requirements for commercial installations across North America, EU, and Eurasian Economic Union markets
The dual-locking mechanism addresses the most common cause of unplanned IT downtime in colocation and enterprise datacenters: accidental power-cord removal during adjacent-rack work or fiber/copper cable pulls. Both the C20 plug and C19 receptacle incorporate spring-loaded retention tabs—pushing the release lever is required to disengage the cord, eliminating the risk of a technician's elbow or a misrouted cable bundle yanking a live connection. This is particularly critical in redundant PSU configurations where a single inadvertent disconnect can shift the full load to the remaining supply, triggering cascade failures in oversubscribed circuits. The 16A rating of the C19/C20 interface supports high-wattage 1U/2U servers (up to 3,840W at 240V), GPU compute nodes, and multi-socket blade chassis without derating, and the 4-foot length keeps excess cable slack to a minimum—reducing airflow obstruction in hot-aisle containment systems and simplifying DCIM cable documentation.
Red jacketing serves dual purposes in structured deployments: phase identification for three-phase delta/wye PDU installations (red/black/blue rotation) and A/B feed segregation in dual-corded equipment racks. In multi-tenant colocation cages, color-coded cords allow at-a-glance verification that customer A's UPS-backed circuits (red) remain isolated from customer B's generator-only feeds (another color), a critical audit control for SLA compliance and uptime SLAs. The high temperature rating—typical of Panduit's SmartZone line—tolerates sustained exposure to exhaust air in rear-door heat exchanger environments and above-rack cable trays in facilities with elevated ambient temperatures, preventing insulation degradation that leads to nuisance breaker trips or ground-fault conditions.
The LPCB02-X is designed for integration with Panduit SmartZone G5 Switched PDUs, rack-mount UPS units with C19 output banks, and enterprise servers equipped with C20 inlet PSUs (common in Dell PowerEdge, HPE ProLiant, and Cisco UCS platforms). The 10-pack packaging suits datacenter refresh projects, new-build rack deployments, and centralized sparing programs—eliminating the need to stock mixed-length/mixed-color inventory for emergency replacements. UL listing validates construction and materials for NEC Article 645 IT equipment installations, CE marking confirms Low Voltage Directive (LVD) and RoHS compliance for EU deployments, and EAC recognition satisfies customs and safety requirements for Russia, Belarus, Kazakhstan, and Armenia markets, making this a global-deployment-ready solution for multinational enterprises and wholesale colocation providers.
Build Your Complete System
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Bundle Summary
Looking for more Panduit products? Shop the full Panduit catalog →
System Design, Deployment & Technical Support
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price
System Design Assistance
- Get help validating product compatibility
- Coverage requirements
- Storage planning and deployment architecture before you buy.
Deployment & Configuration Support
- Access fixed-scope support for rollout planning
- User setup guidance
- Migration and system standardization across single-site or multi-site deployments
Guides, Tools & Calculators
- PoE requirements
- Storage retention
- Camera selection and deployment methodology