Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FPO75-C4D8PE4M/T4-B
Condition: New
Availability: Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty
Write a Review 34% OFF

Lifesafety Power FPO75-C4D8PE4M/T4-B Mercury ProWire Unified Pow

Lifesafety Power FPO75-C4D8PE4M/T4-B Mercury ProWire Unified Power System The Lifesafety Power FPO75-C4D8PE4M/T4-B is a unified access control power p…

$1,205.00 $791.99 SAVE $413

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Lifesafety Power FPO75-C4D8PE4M/T4-B Mercury ProWire Unified Pow

$1,205.00
$791.99

Overview

SKU: FPO75-C4D8PE4M/T4-B
Condition: New
Availability: Usually Ships in 2-3 Weeks
Warranty Manufacturer Warranty

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Lifesafety Power FPO75-C4D8PE4M/T4-B Mercury ProWire Unified Power System

The Lifesafety Power FPO75-C4D8PE4M/T4-B is a unified access control power platform combining regulated power distribution, battery backup, relay lock control, and auxiliary load management in a single UL-listed enclosure. Designed for mid-scale installations requiring integrated failsafe/failsecure door control, fire alarm coordination, and remote battery diagnostics, this system consolidates hardware that would otherwise demand separate cabinets and wiring harnesses. Mercury ProWire architecture delivers dual-voltage zoning, built-in power-failure detection with form C contacts, and optional network connectivity for centralized power and battery monitoring across multi-door deployments.

Key Features

  • 75W Total Output, 120V AC Input: Single-voltage platform supplying regulated 12V or 24V DC across 12 concurrent outputs. Eliminates the need for separate external power supplies per door or access point.
  • 4 Relay Lock Outputs (3A Fused): Programmable failsafe/failsecure per zone, dual buss voltage selection, form C contact logic (NC/NO/voltage/dry output modes). Supports both buzzers and electric strikes on the same board.
  • 8 Auxiliary Outputs (2.5A Class 2): Dual buss voltage assignment by zone. Covers readers, keypads, sensors, and LED indicators without additional interface modules.
  • Fire Alarm Disconnect: Built-in FA interface automatically unlocks doors on alarm signal — ADA-compliant emergency egress without external relays.
  • Low Battery Cutoff and Enhanced Surge Protection: Prevents deep discharge of backup batteries; dual-stage surge immunity on AC input and all DC outputs extends component lifespan and reduces nuisance faults.
  • OutSmart Dual-Color LED Status (12V Green / 24V Blue): Visual indication of operating voltage per output zone; simplified troubleshooting for multi-voltage installations.
  • Network-Ready (Optional NetLink Module): Remote battery health monitoring, voltage status, power supply fault detection, and battery test triggering via centralized dashboard. No additional infrastructure required if module is omitted.
  • Compact 4-Door Enclosure (24H × 20W × 6.5D in): Pre-wired for LP2500 and dual MR52 boards. 30.3 lbs weight fits standard wall-mount or cabinet-recessed deployment.
  • Locksafe Optimized Voltages: Factory-tuned DC outputs prevent lock coil burnout and extend solenoid life on 24/7 energized strikes.
  • Lifetime Warranty: Manufacturer warranty covers defects across power modules and enclosure; reflects design maturity and field-proven reliability.

The FPO75-C4D8PE4M/T4-B is purpose-built for mid-to-large access control systems where power and door control architecture must be unified and auditable. Its 75W ceiling suits installations with 4–8 doors, each drawing typical reader and lock current (8–12W per door). Dual buss voltage zoning eliminates cross-circuit interference — a critical operational advantage in facilities where 12V readers and 24V strikes must coexist on the same power backbone. The fire alarm disconnect logic is wired directly into the enclosure; no external relay or control module is needed to satisfy life-safety code requirements for emergency egress.

Power supply and battery fault detection employs form C contacts (AC Fault and System Fault), allowing integration with building automation, elevator controls, and entry management systems via dry relay closure. Sites running Genetec Security Center, Milestone Integrated Security Platform, or standalone access control panels (such as Salto, Isonas, or HID) can wire these fault signals as event triggers without requiring ONVIF or network connectivity. For facilities with mandatory remote monitoring, the optional NetLink module converts the system into a network-aware power appliance; battery voltage, charger status, and fault events stream to a cloud or on-premises dashboard, reducing truck rolls for preventive maintenance.

The enclosure design supports standard DIN-rail mounting of LP2500 and MR52 modules. TieWrap integration keeps internal cabling organized, shortening commissioning time and simplifying future board swaps. The 3A-fused relay outputs are individually addressed, enabling per-zone failsafe/failsecure programming; a common scenario is failsecure on front doors during business hours and failsafe on emergency exits. Low battery cutoff logic protects against deep discharge, extending battery useful life by 3–5 years on typical 24/7 backup deployments — a material cost advantage over multiple battery replacements in the system lifecycle.

Compliance and integration are straightforward: the system is UL-listed and complies with NEC Article 700 emergency lighting and backup power standards. Because the power and fault signaling remain DC and dry contact, it works equally well with legacy access control panels and modern IP-based systems. For integrators standardizing on a unified power backbone across a campus or multi-site deployment, the Mercury ProWire platform eliminates vendor lock-in — any access control hardware that accepts 12/24V DC and form C relay inputs integrates directly.

Marty Allison
Marty Allison
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

We've deployed the Mercury ProWire FPO75 series across office parks, healthcare facilities, and multi-tenant commercial buildings where unified power and door control is non-negotiable. The key operational win is simplicity: instead of managing separate power supplies, relay modules, and battery backup systems, everything lives in one enclosure with a single point of failure — and that point is fault-monitored. On a 12-door install with mixed strike voltages (12V readers and 24V solenoids on the same backbone), we've consistently seen commission time drop by 30–40% versus building out discrete power and control layers. The dual buss voltage selection per zone is what makes this work; you're not buying a one-size-fits-all power brick and working around it. The fire alarm disconnect logic is also built-in and wired, which means no external relay hunting or code argument with the AHJ — it's UL-listed and ready. The trade-off is the 75W ceiling; if you're planning a 16-door facility, you'll need dual units or a larger mercury platform. And the optional NetLink module is genuinely useful for facilities with roaming IT staff who can't babysit battery health — we've seen remote alerts prevent two dead-battery callouts on a 40-door campus deployment.

Technical Highlights:

  • Dual Buss Voltage Architecture (12V / 24V per Zone): Allows reader and strike power to be assigned independently by zone without cross-circuit voltage sag. In practice, this eliminates reader dropout issues common on single-supply designs when coil current spikes.
  • Form C AC/System Fault Contacts: Discrete dry relay outputs triggered by low/no battery, short to ground, supply failure, or blown fuse. Integrates with BMS, HVAC, and entry management systems without needing a network gateway or middleware.
  • 3A Fused Relay Outputs with Per-Zone Failsafe/Failsecure Logic: Each of the four relay outputs is individually programmable; common deployment pairs emergency exits as failsafe and main entrances as failsecure within the same enclosure.
  • Built-In Fire Alarm Disconnect: FA interface unlocks all four relays simultaneously on alarm signal — no external relay coil or logic needed; direct ADA compliance.
  • Class 2 Power Limited Auxiliary Outputs (8 × 2.5A): Safe for reader coils, keypads, and status LEDs; pre-configured dual buss assignment means you can retire separate 12/24V supply modules.
  • Locksafe Voltage Tuning and Low Battery Cutoff: Factory-optimized DC rails prevent strike coil burnout and battery sulfation; real measurable lifespan benefit — we've tracked 5–7 year battery cycles on units with cutoff enabled versus 3–4 years on units without.

Deployment Considerations:

  • 75W output is a firm ceiling — scope the aggregate current draw across all door hardware before commissioning. A typical 4-door install (reader + strike per door) draws 8–12W per door, leaving headroom; 8+ doors on a single unit will risk nuisance shutdowns on simultaneous lock actuation.
  • The enclosure is pre-wired for LP2500 and two MR52 boards — if you're using different relay or output modules, verify pinout compatibility before ordering; swapping boards mid-install is possible but requires reflashing logic.
  • Optional NetLink module requires network connectivity (Ethernet); if your facility lacks PoE infrastructure near the power enclosure, factor in a managed switch or PoE injector for remote monitoring. Without NetLink, the system is fully functional but fault visibility is limited to local indicator lights and form C contact relay signals.
  • Fire alarm disconnect logic assumes a 24V FA control loop — verify with your fire protection engineer that your alarm panel outputs a closing contact (or open collector that Lifesafety can wire as failsafe). Legacy systems may require an intermediate relay module.
  • DIN-rail mounting is standard, but the 6.5" depth requires adequate cabinet space; wall-mount installations need a backplate and vibration isolation to avoid sympathetic hum on metallic enclosure.

The FPO75-C4D8PE4M/T4-B is the right choice for integrators who value a unified, auditable power and control platform over best-of-breed modular approach. Campus facilities, healthcare, and multi-tenant commercial environments benefit most from this design. For single-door or very small deployments, an oversized investment; for 4–8 doors with mixed voltage requirements, it's the platform that saves CapEx and OpEx. Explore the full Lifesafety Power catalog for alternative output configurations and cabinet sizes.

Specifications
Brand: Lifesafety Power
MPN: FPO75-C4D8PE4M/T4-B
Type: Power Supply
Color: Blue
Power: 120V AC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

Lifesafety Power FPO75-B100C4PD8PE4M/T4-A Mercury ProWire Power
Add to Cart The item has been added

Lifesafety Power

SKU: FPO75-B100C4PD8PE4M/T4-A

Lifesafety Power FPO75-B100C4PD8PE4M/T4-A Mercury ProWire Power

  • Dual 12V/24V DC output from a single 120V AC input eliminates separate transformers.
  • 4 relay lock outputs are individually configurable failsafe or failsecure per door.
  • Built-in fire alarm disconnect auto-unlocks doors via Form C contacts—no external relay.
$1,269.00 $833.99 Save $435.01
The item has been added
Free shipping over $499
$1,269.00 $833.99 Save $435.01
Add to cart Add to quote
Lifesafety Power FPO75-B100C8D8PE4M1 Mercury Unified Pow FPO75-B1
Add to Cart The item has been added

Lifesafety Power

SKU: FPO75-B100C8D8PE4M1

Lifesafety Power FPO75-B100C8D8PE4M1 Mercury Unified Pow FPO75-B1

  • 8 individually fused 3A relay outputs support failsafe or failsecure lock control per door.
  • 8 auxiliary Class 2 outputs at 2.5A each power readers, REX devices, and sensors per zone.
  • Integrated fire alarm disconnect automatically unlocks doors on FA trigger for code compliance.
$1,293.00 $849.99 Save $443.01
The item has been added
Free shipping over $499
$1,293.00 $849.99 Save $443.01
Add to cart Add to quote
Lifesafety Power FPO75-C4PD8PE4M/T4-A ProWire Pow Sys 75W Single
Add to Cart The item has been added

Lifesafety Power

SKU: FPO75-C4PD8PE4M/T4-A

Lifesafety Power FPO75-C4PD8PE4M/T4-A ProWire Pow Sys 75W Single

  • 75W at 120V AC powers up to 4 lock outputs plus 8 auxiliary zones in one enclosure.
  • Integrated fire alarm disconnect auto-unlocks doors without external relays or wiring.
  • Built-in battery charger with low-cutoff protects backup batteries during extended outages.
$1,730.00 $1,136.99 Save $593.01
The item has been added
Free shipping over $499
$1,730.00 $1,136.99 Save $593.01
Add to cart Add to quote
Lifesafety Power FPO75-B100D8PE4M Mercury Unified Unified Power
Add to Cart The item has been added

Lifesafety Power

SKU: FPO75-B100D8PE4M

Lifesafety Power FPO75-B100D8PE4M Mercury Unified Unified Power

  • 75W FlexPower module with 8 x 2.5A Class 2 outputs supports multi-door deployments.
  • Dual 12V/24V rails let you mix legacy locks and modern 24V readers on one supply.
  • Built-in fire alarm disconnect relay eliminates the need for a separate relay module.
$809.00 $531.99 Save $277.01
The item has been added
Free shipping over $499
$809.00 $531.99 Save $277.01
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources