Lifesafety Power
SKU: FPO75-C4D8PE4M/T4-A
Overview
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Overview
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Lifesafety Power FPO75-C4D8PE4M/T4-B is a unified access control power platform combining regulated power distribution, battery backup, relay lock control, and auxiliary load management in a single UL-listed enclosure. Designed for mid-scale installations requiring integrated failsafe/failsecure door control, fire alarm coordination, and remote battery diagnostics, this system consolidates hardware that would otherwise demand separate cabinets and wiring harnesses. Mercury ProWire architecture delivers dual-voltage zoning, built-in power-failure detection with form C contacts, and optional network connectivity for centralized power and battery monitoring across multi-door deployments.
The FPO75-C4D8PE4M/T4-B is purpose-built for mid-to-large access control systems where power and door control architecture must be unified and auditable. Its 75W ceiling suits installations with 4–8 doors, each drawing typical reader and lock current (8–12W per door). Dual buss voltage zoning eliminates cross-circuit interference — a critical operational advantage in facilities where 12V readers and 24V strikes must coexist on the same power backbone. The fire alarm disconnect logic is wired directly into the enclosure; no external relay or control module is needed to satisfy life-safety code requirements for emergency egress.
Power supply and battery fault detection employs form C contacts (AC Fault and System Fault), allowing integration with building automation, elevator controls, and entry management systems via dry relay closure. Sites running Genetec Security Center, Milestone Integrated Security Platform, or standalone access control panels (such as Salto, Isonas, or HID) can wire these fault signals as event triggers without requiring ONVIF or network connectivity. For facilities with mandatory remote monitoring, the optional NetLink module converts the system into a network-aware power appliance; battery voltage, charger status, and fault events stream to a cloud or on-premises dashboard, reducing truck rolls for preventive maintenance.
The enclosure design supports standard DIN-rail mounting of LP2500 and MR52 modules. TieWrap integration keeps internal cabling organized, shortening commissioning time and simplifying future board swaps. The 3A-fused relay outputs are individually addressed, enabling per-zone failsafe/failsecure programming; a common scenario is failsecure on front doors during business hours and failsafe on emergency exits. Low battery cutoff logic protects against deep discharge, extending battery useful life by 3–5 years on typical 24/7 backup deployments — a material cost advantage over multiple battery replacements in the system lifecycle.
Compliance and integration are straightforward: the system is UL-listed and complies with NEC Article 700 emergency lighting and backup power standards. Because the power and fault signaling remain DC and dry contact, it works equally well with legacy access control panels and modern IP-based systems. For integrators standardizing on a unified power backbone across a campus or multi-site deployment, the Mercury ProWire platform eliminates vendor lock-in — any access control hardware that accepts 12/24V DC and form C relay inputs integrates directly.
We've deployed the Mercury ProWire FPO75 series across office parks, healthcare facilities, and multi-tenant commercial buildings where unified power and door control is non-negotiable. The key operational win is simplicity: instead of managing separate power supplies, relay modules, and battery backup systems, everything lives in one enclosure with a single point of failure — and that point is fault-monitored. On a 12-door install with mixed strike voltages (12V readers and 24V solenoids on the same backbone), we've consistently seen commission time drop by 30–40% versus building out discrete power and control layers. The dual buss voltage selection per zone is what makes this work; you're not buying a one-size-fits-all power brick and working around it. The fire alarm disconnect logic is also built-in and wired, which means no external relay hunting or code argument with the AHJ — it's UL-listed and ready. The trade-off is the 75W ceiling; if you're planning a 16-door facility, you'll need dual units or a larger mercury platform. And the optional NetLink module is genuinely useful for facilities with roaming IT staff who can't babysit battery health — we've seen remote alerts prevent two dead-battery callouts on a 40-door campus deployment.
Technical Highlights:
Deployment Considerations:
The FPO75-C4D8PE4M/T4-B is the right choice for integrators who value a unified, auditable power and control platform over best-of-breed modular approach. Campus facilities, healthcare, and multi-tenant commercial environments benefit most from this design. For single-door or very small deployments, an oversized investment; for 4–8 doors with mixed voltage requirements, it's the platform that saves CapEx and OpEx. Explore the full Lifesafety Power catalog for alternative output configurations and cabinet sizes.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Lifesafety Power products? Shop the full Lifesafety Power catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.
Fixed scope • Fixed price