Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric LIBSMG95EUL Li-Ion UPS Battery Cabinet Tower

Overview

The APC by Schneider Electric LIBSMG95EUL is a 67 Ah lithium-ion battery cabinet engineered to extend runtime for large-format UPS systems — specifically the Galaxy VS, Galaxy VL, EPS 7000, and EPS 8000 series. In a tower form factor finished in white, this cabinet accepts up to 16 Li-Ion modules, giving data center and critical-infrastructure operators a scalable path to increasing backup capacity without deploying additional UPS frames. If you're running Galaxy VS or EPS 8K infrastructure and need to expand your runtime window, this is the purpose-built companion cabinet to evaluate.

Lithium-ion chemistry at this scale delivers a meaningful operational advantage over valve-regulated lead-acid (VRLA) alternatives: longer cycle life, faster recharge, and substantially lower weight per kilowatt-hour. For raised-floor data centers where floor-load limits constrain how much battery capacity can be installed, the LIBSMG95EUL's Li-Ion chemistry is often the deciding factor.

Key Features

  • 67 Ah Lithium-Ion Capacity: At 67 Ah, this cabinet provides serious runtime headroom for three-phase critical loads. Li-Ion at this capacity tier also recharges faster than VRLA — critical in environments that experience multiple utility events per year, where slow recharge leaves you exposed during the recovery window.
  • 16-Module Architecture: The cabinet is sized for up to 16 battery modules, which means you can right-size the deployment at install and add modules as load grows — rather than purchasing capacity you won't use on day one. This modularity also supports hot-swap maintenance strategies common in 24/7 operations.
  • Galaxy VS / VL and EPS 7000 / 8000 Compatibility: The LIBSMG95EUL is designed specifically for these APC by Schneider Electric UPS families. Pairing outside this platform is not supported — verify your UPS model before ordering. The tight integration means battery health monitoring and predictive replacement alerts surface directly in EcoStruxure IT or the UPS management interface, not as a blind external cabinet.
  • Tower Form Factor: The tower chassis suits computer room and data center floor deployments where vertical rack space is at a premium or where the UPS itself is tower-mounted. If your Galaxy VS is rack-installed in a standard cabinet row, confirm aisle clearance and floor-load ratings before positioning this unit.
  • White Finish: The white enclosure is consistent with the Galaxy VS/VL aesthetic and is practical in raised-floor environments where visual identification of equipment zones matters during rapid incident response.
  • Scalable Runtime Planning: Deploying the LIBSMG95EUL alongside compatible UPS systems lets engineering teams calculate and extend runtime to meet SLA commitments — relevant for colocation operators and enterprise data centers with contractual uptime obligations that standard internal battery modules cannot satisfy alone.

Integration & Compatibility

The LIBSMG95EUL is purpose-built for the APC by Schneider Electric Galaxy VS, Galaxy VL, EPS 7000, and EPS 8000 UPS platforms. It is not a universal battery cabinet — connection, communication, and battery management integration are specific to these systems. Before specifying the LIBSMG95EUL in a project, confirm the host UPS model and firmware revision support external Li-Ion battery cabinets; older firmware revisions on some Galaxy VS units may require an update before the cabinet is recognized. Integration with UPS and power infrastructure management platforms including EcoStruxure IT Manager is handled through the host UPS, not the cabinet directly. Consult the APC by Schneider Electric system architecture documentation for your specific UPS model to confirm cabinet-to-UPS cabling requirements and maximum number of external battery cabinets supported per frame. For broader UPS battery cabinet options across APC's Galaxy line, including configurations with different module counts, the LIBSESMG16UL (16 × 2.04 kWh modules) is the alternative to evaluate if your runtime math calls for higher per-module energy density.

Frequently Asked Questions

Q: Which UPS systems is the LIBSMG95EUL compatible with?

A: The LIBSMG95EUL is designed for use with APC by Schneider Electric Galaxy VS, Galaxy VL, EPS 7000, and EPS 8000 UPS systems. It is not a universal battery cabinet and should not be paired with other UPS platforms.

Q: How many battery modules does the LIBSMG95EUL support?

A: The cabinet supports up to 16 Li-Ion battery modules, allowing for staged deployment — install fewer modules initially and expand as load or runtime requirements grow.

Q: What is the battery chemistry and capacity of the LIBSMG95EUL?

A: The LIBSMG95EUL uses Lithium-Ion (Li-Ion) battery technology with a rated capacity of 67 Ah. Li-Ion provides longer cycle life and faster recharge compared to traditional VRLA batteries.

Q: What form factor is the LIBSMG95EUL — rack or tower?

A: The LIBSMG95EUL is a tower unit. It is not designed for direct rack mounting. Verify floor space, load ratings, and clearance requirements before placing it alongside rack-mounted UPS equipment.

Q: Is the LIBSMG95EUL available as a standard stocked item?

A: The LIBSMG95EUL is typically a special-order item given its large-format, project-specific nature. Lead times vary — contact pre-sales engineering for current availability and project timelines.

Q: Can the LIBSMG95EUL be monitored through APC's management software?

A: Battery monitoring and health management are handled through the host UPS (Galaxy VS/VL or EPS 7K/8K), which surfaces cabinet status through APC's EcoStruxure IT or the UPS management interface. The cabinet itself does not require a separate network connection.

Eden Phillips
Eden Phillips

The LIBSMG95EUL is one of the few external battery cabinets in this class that commits fully to lithium-ion chemistry at the 67 Ah level — and that distinction matters operationally. When I spec this cabinet on a Galaxy VS or EPS 8K project, the conversation usually starts with recharge time: after a utility event, Li-Ion recovers to full capacity significantly faster than VRLA, which closes the vulnerability window between events. On sites that see two or three utility hits per quarter, that recovery speed is the spec that justifies the premium over lead-acid alternatives.

Technical Highlights:

  • 67 Ah Li-Ion Capacity: Provides extended runtime headroom for three-phase critical loads; Li-Ion's faster recharge cycle is a practical operational advantage on sites with recurring utility instability.
  • 16-Module Scalability: Staged module population lets project teams match installed capacity to actual load on day one and expand without replacing the cabinet — a meaningful total cost of ownership factor on phased data center buildouts.
  • Platform-Native Integration: Because the LIBSMG95EUL is purpose-built for Galaxy VS/VL and EPS 7K/8K, battery health data surfaces directly in the UPS management interface — no third-party monitoring bridge required.

Deployment Considerations:

  • Verify host UPS firmware revision before deployment — some Galaxy VS units require a firmware update before an external Li-Ion cabinet is recognized; missing this step has caused cabinet detection failures on initial commissioning.
  • The tower form factor requires floor space planning distinct from rack-row battery cabinets; confirm raised-floor load ratings at the specific tile location before positioning, particularly in older facilities with non-uniform floor load capacities.

The LIBSMG95EUL is the right specification for enterprise data centers and colocation facilities running Galaxy VS or EPS 8000 infrastructure where contractual runtime SLAs exceed what internal battery modules can deliver — and where the operational cost of slow VRLA recharge is a real risk.

Specifications
Battery Type: Lithium-Ion (Li-Ion)
Capacity: 67 Ah
Module Count: 16
Form Factor: Tower
Color: White
freight: 783.77
Q&A
Reviews

APC by Schneider Electric Li-ion Battery 9540A - LIBSMG95EUL

$46,005.00
$30,406.99

RELATED PRODUCTS

Save $1,815.01
APC Smart-ups Ultra Lithium-ion Battery Pack 1U(SRTL50RMBP1U-LI) - Silver Grey -
Add to Cart The item has been added

APC by Schneider Electric SRTL50RMBP1U-LI

APC by Schneider Electric SRTL50RMBP1U-LI Lithium-ion Battery Pack

50V lithium-ion battery pack designed for 1U rack integration with compatible Smart-UPS Ultra systems

    In stock · Ships same business day Free shipping over $499
    $5,430.00 $3,614.99 Save $1,815.01
    The item has been added Add to quote
    $5,430.00 $3,614.99 Save $1,815.01
    Save $1,815.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources