Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: 4X97A83213
Condition: New
Write a Review

Lenovo 4X97A83213 Thinksystem USB 3.0 Console Breakout Cable for Dense Systems V2

Lenovo 4X97A83213 USB 3.0 Console Breakout Cable Overview The Lenovo 4X97A83213 is a USB 3.0 console breakout cable designed to provide direct manage…

$309.99
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Lenovo 4X97A83213 Thinksystem USB 3.0 Console Breakout Cable for Dense Systems V2

$309.99

Overview

SKU: 4X97A83213
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Lenovo 4X97A83213 USB 3.0 Console Breakout Cable

Overview

The Lenovo 4X97A83213 is a USB 3.0 console breakout cable designed to provide direct management access to Lenovo ThinkSystem dense systems. This cable is essential for initial setup, configuration, and troubleshooting of systems where traditional network management ports may not be immediately accessible or configured. Its primary function is to bridge the system's serial console interface to a standard USB port on a laptop or management station, simplifying deployment in rack environments.

Compatibility

This breakout cable is specifically designed for use with Lenovo ThinkSystem dense systems, particularly those housed within the ThinkSystem DW612S Neptune DWC Enclosure (Machine Type 7D1L). It facilitates console access for the underlying nodes and management controllers within these high-density configurations.

Installation Notes

The cable utilizes a standard USB 3.0 interface for connectivity to a management device. Ensure the target system's console port is accessible and that appropriate drivers are installed on the management station if required by the operating system. The cable's 1.00 lb weight is negligible for installation considerations.

Specifications
Weight: 1.00 lb
Interface: USB
Unspsc Code: 26121620
Components: Specification
Machine Type: 7D1L - 3-year warranty
Form Factor: 6U rack-mounted enclosure.
Enclosure Support: ThinkSystem DW612S Neptune DWC Enclosure
Gpus: NVIDIA HGX H200 or H100 4-GPU board - 4x GPUs interconnected using NVLink 4.0 links
Chipset: Not applicable (platform controller hub functions are integrated into the processor)
Persistent Memory: Not supported
Memory Maximum: Up to 3TB per node with 24x 128GB 3DS RDIMMs
Maximum Internal Storage: E3.S drives: 30.72TB using 2x 15.36TB E3.S NVMe SSDs 7mm drives: 7.68TB using 2x 3.84TB 7mm NVMe SSDs 15mm drives: 3.84TB using 1x 3.84TB 15mm NVMe SSDs
Storage Controllers: 2x Onboard NVMe ports (no hardware RAID available)
Optical Drive Bays: No internal bays; use an external USB drive.
Pcie Slots: None.
Ports: Two RJ45 port on the rear of the enclosure for 10/100/1000 Ethernet connectivity to the SMM for power and cooling management.
Video: Embedded video graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Security Features: Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 2.0. In China only, optional Nationz TPM 2.0 plug-in module (support is planned).
Dimensions: Width: 447 mm (17.6 in.), height: 264 mm (10.4 in.), depth: 933 mm (36.7 in.). See Physical and electrical specifications for details.
Enclosures Per Rack: Up to six DW612S enclosures per 42U rack and up to seven DW612S enclosures per 48U rack.
I/O Architecture: None integrated. Use top-of-rack networking and storage switches.
Cooling: Direct water cooling supplied by water manifolds connected from the rear of the enclosure.
System Leds: SMM has four LEDs: system error, identification, status, and system power. Each power supply has AC, DC, and error LEDs. Nodes have more LEDs.
Electrical Power: 200 V - 240 V ac input (nominal), 50 or 60 Hz
Power Cords: One C19 AC power cord for each air-cooled power supply Three C19 AC power cords for each water-cooled power supply
Machine Type/Model: Description
7Dazctolww: ThinkSystem SD665-N V3 Neptune DWC Tray (3-Year Warranty)
7D1Lcto2Ww: ThinkSystem DW612S Neptune DWC Enclosure (3-Year Warranty)
5469Hc1: Lenovo Neptune DWC Node Manifold
Feature Code: Description
A5Mn: Lenovo Neptune DWC Manifold Assembly for 1 Enclosure w/ 1.3m hose
A5N7: Lenovo Neptune DWC Manifold Assembly for 2 Enclosures w/ 1.3m hose
A5N8: Lenovo Neptune DWC Manifold Assembly for 3 Enclosures w/ 1.3m hose
A5N9: Lenovo Neptune DWC Manifold Assembly for 4 Enclosures w/ 1.3m hose
Bezx: Lenovo Neptune DWC Manifold Assembly for 5 Enclosures w/ 2.3m hose
Bezw: Lenovo Neptune DWC Manifold Assembly for 6 Enclosures w/ 2.3m hose
Bjak: Lenovo Neptune DWC Manifold Assembly for 7 Enclosures w/ 2.3m hose
Bn0S: Neptune DWC Manifold Assembly for Water-Cooled Power Supplies for 42U Rack Cabinet
Bv8R: Neptune DWC Manifold Assembly for Water-Cooled Power Supplies for 48U Rack Cabinet
Brgp: Neptune DWC Manifold Assembly for 1 Enclosure
Brgn: Neptune DWC Manifold Assembly for 2 Enclosure
By38: Neptune DWC Manifold Assembly for 3 Enclosure
By39: Neptune DWC Manifold Assembly for 4 Enclosure
Brgm: Neptune DWC Manifold Assembly for 5 Enclosure
Brgl: Neptune DWC Manifold Assembly for 6 Enclosure
Brgq: Neptune DWC Manifold Assembly for water-cooled Power Supplies with in-rack CDU
4Xf7B07632: Neptune DWC Manifold Extended Commissioning Kit
4Xf7A84654: Neptune DWC Manifold Commissioning Kit
Cto Model: Base feature
7Dblctolww: BRL4
Brm4: Neptune DWC In-Rack CDU Connection Assembly for DWC Manifold
Brm3: Neptune DWC In-Rack CDU 2.3m Primary Loop Connection Hose
Brl3: Neptune DWC In-Rack CDU Filler Kit
C2Ak: 9135
C2Ar: 9175F
C2Ap: 9255
C2At: 9275F
C2Aq: 9335
C2Az: 9355
C2Av: 9355P
C2Am: 9365
C2Aj: 9375F
C2Nd: 9455
C2Ne: 9455P
C2A3: 9475F
C2Al: 9535
C2Ay: 9555
C2Aw: 9555P
C2As: 9565
C4H8: 9575F
C2Au: 9655
C2Ax: 9655P
C2An: 9645
C2Ae: 9745
C2Ah: 9825
C2Td: 9845
Bree: 9124
Brej: 9174F
Breh: 9224
Bred: 9254
Bref: 9274F
Brec: 9334
Br30: 9354
Breg: 9354P
Br32: 9374F
Breb: 9454
Brem: 9454P
Br31: 9474F
Brea: 9534
Bpvj: 9554
Brel: 9554P
Br2Z: 9634
Bpvk: 9654
Brek: 9654P
Bxft: 9184X
Bw9V: 9384X
Bw9U: 9684X
Bw9S: 9734
Bw9T: 9754
Epyc Model: Cores / Threads
9175F: 16 / 32
9275F: 24 / 48
9355P: 32 / 64
9375F: 32 / 64
9455P: 48 / 96
9475F: 48 / 96
9555P: 64 / 128
9575F: 64 / 128
9655P: 96 / 192
9174F: 16 / 32
9274F: 24 / 48
9354P: 32 / 64
9374F: 32 / 64
9454P: 48 / 96
9474F: 48 / 96
9554P: 64 / 128
9654P: 96 / 192
9184X: 16 / 32
9384X: 32 / 64
9684X: 96 / 192
Bfya: Operating mode selection for: "Maximum Efficiency Mode"
Bfyb: Operating mode selection for: "Maximum Performance Mode"
4X77A93528: C0CK
4X77A93533: C0CP
4X77A93529: C0CL
4X77B07420: CA1L
4X77B07424: CA1Q
4X77B07421: CA1M
4X77A93527: C0CJ
4X77A93532: C0CN
4X77B07419: CA1K
4X77A81442: BQ36
4X77A81441: BQ3D
4X77A81448: BUVV
4X77A96982: C467
4X77A81437: BQ3C
4X77A85812: BUVT
4X77A81440: BQ37
4X77A81447: BUVU
4X77A81443: BQ3A
C3V2: ThinkSystem NVIDIA HGX H200 141GB 700W 4-GPU Board
Bubb: ThinkSystem NVIDIA H100 SXM5 700W 94G HBM2e GPU Board
Bqqv: ThinkSystem NVIDIA H100 SXM5 700W 80G HBM3 GPU Board
Specification: H200
Fp64: 34 teraFLOPS
Fp64 Tensor Core: 67 teraFLOPS
Fp32: 67 teraFLOPS
Tf32 Tensor Core: 989 teraFLOPS*
Bfloat16 Tensor: 1,979 teraFLOPS*
Fp16 Tensor Core: 1,979 teraFLOPS*
Fp8 Tensor Core: 3,958 teraFLOPS*
Int8 Tensor Core: 3,958 TOPS*
Gpu Memory: 141 GB HBM3e
Gpu Memory Bandwidth: 4.8 TB/s
Multi-Instance Gpus: Up to 7 MIGS @ 10 GB
Interconnect: NVLink: 900 GB/s, PCIe Gen5: 128 GB/s
Tgp Setting: Feature code
700W: BS3P
600W: BS3Q
500W: BS3R
Bzu2: ThinkSystem SD665, SD665-N V3 1x E3.S 1T Storage Cage
Bu9S: ThinkSystem SD665, SD665-N V3 2x E3.S 1T Storage Cage
Byu4: ThinkSystem SD665, SD665-N V3 1x2.5" 7mm NVMe Storage Cage
Byau: ThinkSystem SD665, SD665-N V3 2x2.5" 7mm NVMe Storage Cage
Bpzb: ThinkSystem SD665, SD665-N V3 1x2.5" 15mm NVMe Storage Cage
4Xf7A85263: ThinkSystem SD665-N V3 NVMe Storage Option Upgrade Kit
4Xf7A86739: ThinkSystem SD665-N V3 E3.S 1T Storage option upgrade kit
Cto Only: B0MK
4Xb7A93367: C67G
4Xb7A93368: C67H
4Xb7A93369: C67J
4Xb7A93370: C67K
4Xb7A88775: BWS1
4Xb7A88776: BWS2
4Xb7A88777: BWS3
4Xb7A88778: BWS4
4Xb7B09654: CBT3
4Xb7B09655: CBT4
4Xb7B09656: CBT5
4Xb7A13975: BKSQ
4Xb7A13976: BKWR
4Xb7A13977: BKWS
4Xb7A82609: BW8Q
4Xb7A82411: BW8R
4Xb7A88392: BW8S
4Xb7A88393: BW8T
4Xb7B09660: CBT9
4Xb7B09661: CBTA
4Xb7B09662: CBT2
4Xb7B01887: C7P5
4Xb7B01888: C7P6
4Xb7B01889: C7P7
4Xb7A76781: BKT5
4Xb7A76782: BKT6
4Xb7A72437: BVGS
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources