Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv CPQ-1077590-02 is a 30kW (102,000 BTUH) air-cooled precision cooling unit built for data centers, telecom rooms, and edge compute environments where thermal load management is non-negotiable. Paired with an outdoor heat exchanger (OHE), it handles ambient rejection from -31°F to 126°F — a range that covers northern deployments with hard winters and desert-climate facilities without separate cold-weather packages. If you're sizing a new room or retrofitting an existing raised-floor deployment, this unit lands in a capacity tier that covers most mid-density server rows without chaining multiple smaller units together.
The CPQ-1077590-02 (often searched as CPQ 1077590 02) integrates with Vertiv's Liebert® iCOM™ control platform alongside SNMP and Modbus — meaning it speaks the protocols your BMS or DCIM already understands, and doesn't require a proprietary gateway appliance to pull telemetry into a unified management dashboard.
The CPQ-1077590-02 is designed to integrate into standard data center control architectures. SNMP support means the unit can report alarms and telemetry to any SNMP-capable DCIM or NMS platform. Modbus RTU/TCP compatibility opens integration paths with building automation systems (BAS) and energy management platforms that don't speak SNMP natively. Liebert® iCOM™ provides local and networked control with Vertiv's full-featured cooling management interface, including multi-unit coordination for N+1 redundancy configurations. Size condenser line sets within the 390 ft. maximum and account for vertical rise limits per Vertiv's installation specifications for the refrigerant circuit.
Q: What is the total cooling capacity of the CPQ-1077590-02?
A: The CPQ-1077590-02 delivers 30kW (102,000 BTUH) of nominal cooling capacity with 3,900 CFM of airflow.
Q: What is the maximum condenser pipe run distance for this unit?
A: The CPQ-1077590-02 supports condenser pipe runs up to 390 feet, providing significant installation flexibility for rooftop or remote condenser placements.
Q: What ambient temperature range does the outdoor heat exchanger support?
A: The air-cooled outdoor heat exchanger (OHE) operates across an allowable heat rejection range of -31°F to 126°F, covering cold-climate and hot-climate deployments within a single unit configuration.
Q: What monitoring and control protocols does the CPQ-1077590-02 support?
A: The unit supports SNMP, Modbus, and Vertiv's Liebert® iCOM™ control platform, enabling integration with DCIM, BMS, and building automation systems without requiring proprietary gateways.
Q: Does the CPQ-1077590-02 include a redundant power supply?
A: Yes, a redundant power supply option is available that automatically switches to a backup source during an outage, adding uptime protection at the cooling infrastructure layer.
Q: How does the inverter-driven compressor affect energy efficiency?
A: The inverter-driven compressor dynamically adjusts output to match actual heat load rather than cycling at fixed capacity. This reduces power consumption during partial-load operation — which represents the majority of runtime in most facilities — and lowers mechanical wear over the unit's service life.

The CPQ-1077590-02 sits in a capacity tier that gets specified a lot for mid-density deployments — 30kW is enough to cool a fully loaded row without paralleling units, and the 390 ft. pipe run limit is the spec I look at first when there's a constrained mechanical routing situation. Most competing units in this class cap at 200 ft., which rules them out on multi-story buildings or campus sites where the condenser pad is far from the indoor unit. This one doesn't have that problem.
Technical Highlights:
Deployment Considerations:
The CPQ-1077590-02 is a strong fit for edge data centers, secondary colocation facilities, and enterprise server rooms where water-side cooling infrastructure doesn't exist and condenser routing flexibility is required. If you're building a new mid-density room and want to avoid the operational complexity of a chilled-water loop, this is the unit to put on your short list.