Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv ITA2LI-30KRT208V23UPN 15KVA 208V 2+0 Parallel Li-ion UPS Bundle

Overview

The Vertiv ITA2LI-30KRT208V23UPN is a 15KVA, 208V lithium-ion UPS bundle configured in a 2+0 parallel architecture — a factory-packaged solution designed for data centers, network closets, and critical infrastructure deployments where power continuity directly affects operations. This bundle brings together the Liebert ITA2 UPS platform's Li-ion chemistry and parallel redundancy in a single SKU, simplifying procurement for IT architects and facilities teams specifying multi-unit installations.

The ITA2 platform at this power class supports 15/20KVA at 208V, placing it in the range appropriate for mid-density rack environments, edge computing nodes, and security or surveillance infrastructure that cannot tolerate downtime. Li-ion battery chemistry — compared to traditional VRLA — typically delivers a longer service life and reduced weight per kilowatt of backup capacity, which matters in rack-dense installations where floor loading and battery replacement cycles carry real operational cost.

The 2+0 parallel configuration means both UPS units share the load actively. For buyers evaluating UPS systems in this class, note that 2+0 differs from N+1 redundancy: both modules are load-bearing, so a single-unit failure reduces available capacity rather than providing seamless failover. If your application requires true fault tolerance, confirm whether a 1+1 or N+1 parallel configuration is the appropriate topology for your site's criticality tier.

As part of the broader Vertiv power protection line, the ITA2LI-30KRT208V23UPN (often searched as ITA2LI 30KRT208V23UPN) is positioned for installations where space efficiency, Li-ion longevity, and a bundled parallel deployment reduce integration complexity versus assembling individual units and parallel kits separately.

Key Features

  • 15/20KVA at 208V: Covers mid-density rack loads typical of security NVR clusters, server rooms, and edge IT infrastructure — enough headroom to handle simultaneous UPS startup inrush without nuisance trips.
  • Li-ion Battery Chemistry: Li-ion cells generally outlast VRLA alternatives in cycle life, which reduces the frequency and cost of planned battery replacements — a real factor in unmanned remote sites or facilities with limited maintenance windows.
  • 2+0 Parallel Bundle: Factory-packaged as a two-unit set eliminates the coordination overhead of sourcing parallel kits separately, reducing configuration errors at commissioning.
  • 208V Input/Output: Matches standard North American three-phase commercial distribution, compatible with typical data center PDU and rack power configurations without step-down transformers.

Integration & Compatibility

The Liebert ITA2 series is designed to integrate with network management and building management systems via optional communication cards — verify specific card compatibility with your SNMP or BMS infrastructure before ordering. For facilities running parallel UPS architectures, confirm that your site's static transfer switch or STS topology aligns with a 2+0 (load-sharing) versus a redundant (N+1) deployment model. Battery runtime at full 15KVA load should be confirmed against the published runtime curves for this specific Li-ion configuration prior to finalizing runtime SLAs with stakeholders.

Frequently Asked Questions

Q: What is the difference between the 2+0 parallel configuration and N+1 redundancy?

A: In a 2+0 configuration, both UPS units actively share the load — if one unit fails, the remaining unit must carry the full load, which may exceed its solo capacity. N+1 or 1+1 redundancy keeps one unit as a standby so a single failure causes no capacity reduction. Choose your topology based on your site's criticality and load profile.

Q: Why specify Li-ion over traditional VRLA batteries for this application?

A: Li-ion batteries typically offer a longer cycle life and lower weight compared to VRLA, which can reduce long-term replacement costs and ease rack weight constraints in dense deployments. They also generally tolerate higher ambient temperatures better than VRLA, which is relevant in equipment rooms without precision cooling.

Q: What power rating does the ITA2LI-30KRT208V23UPN support?

A: The Liebert ITA2 at this voltage class supports 15/20KVA at 208V. Confirm the exact active rating for the bundle configuration with your pre-sales engineer prior to sizing your distribution.

Q: Is the ITA2LI-30KRT208V23UPN compatible with third-party network management systems?

A: The ITA2 platform supports optional communication cards for SNMP and BMS integration. Specific card compatibility and supported protocols should be confirmed against your NMS requirements before purchasing.

Q: Can this UPS bundle be expanded to a redundant (N+1) configuration later?

A: Parallel architecture expandability depends on the specific firmware and hardware revision of the ITA2 units in the bundle. Consult Vertiv's configuration documentation or your pre-sales engineer to confirm upgrade paths before committing to a topology.

Karl Wilson
Karl Wilson

The ITA2LI-30KRT208V23UPN is one of those SKUs that looks straightforward on paper — 15KVA, 208V, Li-ion, parallel bundle — but the topology decision embedded in that "2+0" designation is the most consequential spec on the sheet. A 2+0 load-sharing configuration means your effective fault tolerance is zero: lose one module and you're running a single UPS at or above its rated capacity, likely triggering an overload shutdown rather than a graceful failover. That's the conversation to have before the PO is cut.

Technical Highlights:

  • 15/20KVA at 208V: Headroom in this power class handles mid-density rack environments — NVR clusters, edge compute nodes, and security infrastructure hubs — without constant proximity to capacity ceilings.
  • Li-ion Chemistry: The service life advantage over VRLA is real in practice, particularly in facilities where battery swap logistics are disruptive or where ambient temps run warmer than VRLA recommends.
  • Bundle SKU: Procuring the parallel pair as a single ITA2LI-30KRT208V23UPN SKU rather than two independent units plus a separate parallel kit reduces receiving, staging, and commissioning complexity — a small but genuine operational win.

Deployment Considerations:

  • Confirm your PDU and panel infrastructure is wired for 208V three-phase before specifying this unit — a mismatch here causes field delays that dwarf any procurement savings.
  • 2+0 is not the same as redundant: if your load SLA requires power continuity through a single-unit failure, budget for a 1+1 or N+1 parallel topology instead, and revisit the SKU selection accordingly.

The ITA2LI-30KRT208V23UPN fits best in a planned, dual-module 208V installation where the site engineer has already confirmed that load-sharing (not hot-standby redundancy) is the acceptable failure mode — such as a secondary edge node or a non-mission-critical data closet where a brief maintenance window is tolerable.

Specifications
Models: Power Rating
Liebert® Ita2 Ups 5Kva, 208V: 5kVA
Liebert® Ita2 Ups 8/10 Kva, 208V: 8/10kVA
Liebert® Ita2 Ups 15/20Kva, 208V: 15/20kVA
freight: 620.82
Q&A
Reviews

Vertiv ITA2 15KVA 208V 2+0 Parallel UPS Li-ion Bundle. - ITA2LI-30KRT208V23UPN

$85,302.00
$58,888.99

RELATED PRODUCTS

Save $41,948.01
Image coming soon
Add to Cart The item has been added

Vertiv ITA2LI-40KRT208V33UPRN

Vertiv ITA2 20KVA 208V 2+1 PARALLEL UPS LI-ION BUNDLE. - ITA2LI-40KRT208V33UPRN

40kVA, 208V uninterruptible power supply (UPS) system designed for critical IT infrastructure, including server rooms and data centers

    Usually Ships in 2-3 Weeks Free shipping over $499
    $135,315.00 $93,366.99 Save $41,948.01
    The item has been added Add to quote
    $135,315.00 $93,366.99 Save $41,948.01
    Save $41,948.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources