Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: EDV18-250M-Q
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 85% OFF

Panduit EDV18-250M-Q StrongHold Male Disconnect 22-18AWG

Panduit EDV18-250M-Q StrongHold™ Male Disconnect Terminal The Panduit EDV18-250M-Q delivers field-serviceable wiring connections for access control pa…

$6.60 $0.99 SAVE $6

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit EDV18-250M-Q StrongHold Male Disconnect 22-18AWG

$6.60
$0.99

Overview

SKU: EDV18-250M-Q
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit EDV18-250M-Q StrongHold™ Male Disconnect Terminal

The Panduit EDV18-250M-Q delivers field-serviceable wiring connections for access control panels, security system enclosures, and low-voltage control circuits where quick disconnect capability matters. This StrongHold™ male disconnect terminal handles 22-18 AWG wire with a 0.250 × 0.032" tab interface, combining tin-plated copper construction with vinyl barrel insulation for corrosion resistance and electrical isolation. cULus listed under E78522, these terminals meet NEC and CEC requirements for low-voltage control wiring in commercial security installations.

Key Features

  • 22-18 AWG wire range accommodates standard control and signal wiring
  • 0.250 × 0.032" male tab fits industry-standard quick-disconnect receptacles
  • Tin-plated copper contact surface resists oxidation in enclosures and plenum spaces
  • Vinyl barrel insulation rated for 600V, color-coded for wire gauge identification
  • cULus listed (E78522) for installation authority compliance
  • StrongHold™ crimp barrel design provides gas-tight mechanical and electrical connection
  • Compatible with Panduit CT-1525, CT-2300/ST, and CT-2500/L crimping tools
  • 25-piece package supports typical access control panel or small enclosure build

The StrongHold crimp barrel uses a serrated interior surface and mechanical geometry engineered to cold-weld stranded copper conductors during crimping, creating a gas-tight bond that resists vibration loosening and thermal cycling. The vinyl insulation extends support to the wire jacket transition point, reducing stress concentration that causes conductor fatigue in frequently opened enclosures. Tin plating on the contact tongue maintains low contact resistance across the temperature and humidity swings common in non-climate-controlled equipment rooms and outdoor-rated NEMA enclosures. The 0.250" tab width is the industry-standard size for panel-mount components including relays, terminal blocks, power supplies, and lock control boards used in access control and intrusion systems.

Deploy these terminals for wiring connections that must be field-serviceable without cutting wire—door position switches, request-to-exit sensors, auxiliary relay outputs, and power distribution to access readers. The quick-disconnect design lets technicians swap failed components or troubleshoot circuits without decommissioning entire wire runs, a critical advantage in retrofit projects where pulling new cable through finished walls isn't viable. Proper crimping requires Panduit's ratcheting tools (CT-1525, CT-2300/ST, CT-2500/L), which apply controlled six-point compression and won't release until the crimp cycle completes—hand crimpers and generic tools undercompress the barrel, leading to high-resistance joints that fail under load. The 22-18 AWG range covers the wire gauges specified for most manufacturer-supplied pigtails and field-run low-voltage control circuits; verify wire gauge via jacket markings or a wire stripper gauge before crimping.

cULus listing under file E78522 confirms these terminals meet UL 310 (electrical quick-connect terminals) and CSA C22.2 standards for use in Listed control panels and fire alarm systems—required for installations subject to inspection by AHJs enforcing NEC Article 725 (Class 2 and Class 3 circuits). Tin plating provides the corrosion resistance needed in security enclosures where dissimilar metals, condensation from temperature swings, and exposure to concrete dust or coastal salt air would corrode bare copper contacts within months. This 25-piece package aligns with the connection count in typical single-door access control installations or small intrusion panel builds; carton quantity is 250 pieces for integrators running multi-door projects or stocking service van inventory.

Specifications
Product Type: Male Disconnect Terminal
Sub-Brand: StrongHold™
Wire Gauge Range: 22-18 AWG
Tab Size: 0.250 × 0.032 in
Insulation Material: Vinyl
Contact Material: Tin-Plated Copper
Voltage Rating: 600V
Overall Length: 0.98 in
Overall Width: 0.25 in (6.3 mm)
Standards Met: cULus Listed (E78522)
Compatible Tools: CT-1525, CT-2300/ST, CT-2500/L
Package Quantity: 25 pieces
Carton Quantity: 250 pieces
UPC: 61305636667
Competitor Cross-Reference: TV18250MDXV
Type: Male Disconnect Terminal
Connectivity: Quick Disconnect
Sub Brand: StrongHold™
Width In: 0.25
Width Mm: 6.3
Carton Qty: 250
Package Qty: 25
Standards: cULus, E78522
Cable Category: wire-termination
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources