Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: HU4A4A5013Q
Condition: New
Write a Review 14% OFF

HPE HU4A4A5013Q DL380 G12 Storage Server FOR DP Supp

HPE HU4A4A5013Q 3-Phase High-Density PDU for DL380 G12 StorageOverviewThe HU4A4A5013Q is a high-density, 3-phase rack PDU designed to power HPE DL380 …

$22,196.00 $19,073.99 SAVE $3122
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

HPE HU4A4A5013Q DL380 G12 Storage Server FOR DP Supp

$22,196.00
$19,073.99

Overview

SKU: HU4A4A5013Q
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

HPE HU4A4A5013Q 3-Phase High-Density PDU for DL380 G12 Storage

Overview

The HU4A4A5013Q is a high-density, 3-phase rack PDU designed to power HPE DL380 Gen12 storage server deployments configured for data protection (DP) workloads. With a total PDU output capacity of 14,720W across dual feed inputs, this unit addresses the power density demands of fully-loaded storage racks where a single-phase PDU would either oversubscribe the circuit or require multiple units to cover outlet count. Each feed input (labeled ~A and ~B) draws from a 200–240V, 32A, 3-wire circuit with a Category D breaker requirement — plan your panel capacity accordingly before rack deployment.

Compatibility

Designed for use with HPE ProLiant DL380 Gen12 servers configured in storage or data protection roles. The dual IEC309 3-pin, 32A input plugs require matching receptacles at the rack or floor PDU level — verify your raised-floor or overhead busway termination type before ordering. The outlet mix (72x C13 at 10A each, 6x C19 at 16A each) is matched to the DL380 G12 platform's power supply inlet standards; C13 outlets feed standard 10A PSUs while C19 handles higher-draw components. Load segments are balanced across three phases (L1, L2, L3) at 20A per segment per feed — a balanced 3-phase configuration reduces neutral current and simplifies power monitoring in managed rack environments.

Installation Notes

Each of the two input feeds (~A and ~B) requires its own dedicated 200–240V, 3-wire, 32A circuit with a Category D breaker — Category D is mandatory for the inrush characteristics of this PDU; substituting a standard Type B or C breaker risks nuisance tripping under storage workload spin-up. Total load per feed is capped at 32A (7,360W); combined PDU capacity reaches 14,720W only when both feeds are active and balanced. Verify that your data center power infrastructure supports dual IEC309 32A feeds at the rack position before racking this unit. Country of origin is United States.

Specifications
Country Origin: US
Country Of Origin: US
Unspsc Code: 81111812
Input Voltage Rating: Voltage (VAC)
Branch Circuit Requirements: 200-240V, 3-wire, 32A circuit, Category D Breaker
Input Plug/Cord Rating: (2) - IEC309 3-pin, 32 Amps
Output Voltage Rating: Voltage (VAC)
Outlet Rating: ~A: C13 Outlet @ 10A ~B: C13 Outlet @ 10A ~A: C19 Outlet @ 16A ~B: C19 Outlet @ 16A
Load Segment: ~A: L1 @ 20A ~B: L1 @ 20A ~A: L2 @ 20A ~B: L2 @ 20A ~A: L3 @ 20A ~B: L3 @ 20A
Total Load All Segments: ~A: 32A ~B: 32A
Line Cord & Pdu Total Power: 7360 W
Number Of Outlets: C13 Outlet
C19 Outlet: ~A: 3 (1 per segment) ~B: 3 (1 per segment)
Line Cord Total Power: ~A: 7.360W ~B: 7,360W
Pdu Total Power: 14,720W
Pdu Total: C13 Outlet: 72 C19 Outlet: 6
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources