Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: P78791-B21
Condition: New
Write a Review

HPE 7.68TB NVME GEN5 High Performance Read Intensive E3.S EC1 PM1753 SSD - P78791-B21

HPE P78791-B21 7.68TB NVMe Gen5 High-Performance SSD Overview The HPE P78791-B21 is a 7.68TB NVMe Gen5 solid-state drive in E3.S form factor, enginee…

$70,809.99
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

HPE 7.68TB NVME GEN5 High Performance Read Intensive E3.S EC1 PM1753 SSD - P78791-B21

$70,809.99

Overview

SKU: P78791-B21
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

HPE P78791-B21 7.68TB NVMe Gen5 High-Performance SSD

Overview

The HPE P78791-B21 is a 7.68TB NVMe Gen5 solid-state drive in E3.S form factor, engineered for read-intensive workloads in enterprise surveillance and analytics environments. This drive delivers the throughput and capacity required for continuous multi-camera recording systems, fast replay operations, and analytics processing on centralized storage architectures where sustained sequential access patterns dominate.

Key Features

  • 7.68TB capacity: Eliminates the need for drive spanning in mid-scale to large surveillance deployments—one drive handles what previously required two or three smaller units, reducing cabling complexity and RAID parity overhead.
  • NVMe interface: Direct PCIe connection eliminates SATA bottlenecks (limited to ~550 MB/s sequential). NVMe enables sustained multi-gigabyte-per-second throughput necessary when 20+ cameras stream simultaneously to a single storage node.
  • PCIe Gen5: Doubles bandwidth versus Gen4 (64 GB/s vs. 32 GB/s theoretical), meaning higher headroom for burst writes during peak recording periods and faster restoration of degraded RAID arrays without throttling live ingest.
  • E3.S form factor: Shorter, wider envelope than U.2 that fits dense server architectures (1U/2U appliances) while maintaining passive cooling—no active heatsinks needed in most surveillance platforms.
  • Read-intensive profile: Optimized for playback, forensic review, and analytics queries where reads far outweigh writes. This tuning lowers cost-per-TB compared to mixed-use or write-optimized variants while delivering deterministic read latency for smooth VMS scrubbing and export.
  • PM1753 model designation: HPE's enterprise-grade SSD line with full telemetry support (SMART data, predictive failure alerts) integrable with HPE iLO management and third-party storage monitoring tools.

Integration & Compatibility

The P78791-B21 integrates with any HPE ProLiant server, Apollo storage node, or third-party NVMe-capable storage appliance equipped with an M.2 or E3.S slot and appropriate firmware support. Works with software RAID stacks (ZFS, mdadm on Linux), hardware RAID controllers with NVMe passthrough, or direct-attach NVMe arrays in hyperscale surveillance systems. Confirm your platform's NVMe driver version—older Gen4-era systems may not report full Gen5 bandwidth, though backward compatibility ensures the drive will operate at reduced speed with no data loss.

What's in the Box

HPE P78791-B21 7.68TB NVMe Gen5 E3.S SSD. Mounting bracket and documentation vary by retailer fulfillment source—verify with your supplier if you require specific mounting hardware or compliance certificates.

Frequently Asked Questions

Q: Is the P78791-B21 compatible with my HPE ProLiant Gen11 server?

A: Yes. The P78791-B21 works in any HPE server with an M.2 or E3.S NVMe slot. Check your server's technical specifications to confirm slot availability and firmware version; Gen11 and newer typically support Gen5 natively.

Q: What's the expected lifespan of the P78791-B21 in continuous surveillance recording?

A: HPE rates enterprise SSDs for 5–7 years in mixed-use environments. Read-intensive workloads (where the P78791-B21 is optimized) typically extend drive life by reducing write wear. Monitor SMART health via iLO or your storage appliance's management console for predictive failure alerts.

Q: Can I use the P78791-B21 in a RAID array with mixed drive capacities?

A: Yes, RAID controllers and software stacks will adapt, but the array stripe size will match your smallest drive. For performance and predictability, deploy matched sets of identical capacity and model.

Q: Does the P78791-B21 require active cooling or heatsinks?

A: The E3.S form factor and HPE PM1753 design support passive thermal management in most 1U/2U platforms. If your system runs above 55°C ambient or has restricted airflow, verify thermal simulation with HPE or your storage vendor before deployment.

Q: Is the P78791-B21 included on the HPE Qualified Products List for my storage appliance?

A: Check the hardware compatibility matrix in your appliance's documentation or HPE's support portal. The PM1753 line is widely qualified across ProLiant, Apollo, and third-party NVMe-capable systems.

Eden Phillips
Eden Phillips

The P78791-B21 addresses a real pain point in large-scale surveillance deployments: SATA-based storage simply cannot sustain the aggregate write throughput when 30+ IP cameras push H.265 streams to a single storage node. The 7.68TB capacity in E3.S form factor lets you consolidate what used to require three or four smaller drives into a single slot, and PCIe Gen5 eliminates the bottleneck entirely—you're looking at 5+ GB/s sustained throughput instead of 550 MB/s ceilings.

Technical Highlights:

  • PCIe Gen5 bandwidth (64 GB/s): Real-world sustained writes in RAID environments hit 3–4 GB/s with modern controllers, compared to ~300 MB/s on SATA. That margin matters when you're striping video from 40 cameras without write throttling or frame drops.
  • 7.68TB single drive: Reduces RAID overhead and rebuild times. A degraded three-drive RAID6 set with Gen4 SSDs could take 12+ hours to rebuild; Gen5 cuts that to 4–5 hours, and the larger single drive means fewer stripe members overall.
  • Read-intensive tuning: The P78791-B21 is optimized for playback and forensic queries (90%+ reads in surveillance workloads), not constant writes. That optimization lowers endurance wear, meaning the drive lasts 6–7 years in real deployments instead of 4–5.

Deployment Considerations:

  • Verify your server firmware supports Gen5 NVMe. Older iLO versions may see the drive, but the platform won't report full bandwidth—it will throttle to Gen4 speeds. A firmware update is usually the fix.
  • E3.S form factor is physically shorter than U.2, but wider—confirm physical clearance in your server's drive bays before ordering. Some 1U platforms have tight horizontal spacing.

Deploy the P78791-B21 in centralized recording architectures (1–3 storage nodes serving 50+ cameras) or in appliances with fast local playback and analytics. It's overkill for small remote sites with 4–6 cameras, where a smaller NVMe or SATA drive is sufficient; it shines in enterprise command centers and multi-site hub-and-spoke systems where sustained ingest and forensic review are constant demands.

Specifications
Storage Capacity: 7.68 TB
Interface: NVMe
Form Factor: E3.S
PCIe Generation: Gen5
Drive Type: Read Intensive
SSD Model: PM1753
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources