Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: AM3305
UPC: 604840833059
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks
Write a Review 39% OFF

HES AM3305 Maglock Mounting Brackets

Industrial maglock brackets for HES systems on standard door frames

$54.00 $32.99 SAVE $21
Special Order
Usually Ships in 2-3 Weeks

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Experts for pre and post-sales support
Technical and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

Specialized training • U.S - based

Senior Specialist • 877-277-7147

HES AM3305 Maglock Mounting Brackets

$54.00
$32.99

Overview

SKU: AM3305
UPC: 604840833059
Condition: New
Availability: Special Order · Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

HES AM3305 Maglock Mounting Brackets

The HES AM3305 is an industrial-grade mounting bracket system engineered to support electromagnetic lock installations across commercial and institutional security deployments. These brackets provide the structural foundation needed to mount HES maglock systems securely on standard door frames, ensuring reliable access control operation in high-traffic and high-security environments.

Key Features

  • Industrial-Grade Construction: Purpose-built for demanding commercial installations where maglock durability and mounting integrity are non-negotiable. This level of material quality and fabrication tolerances directly reduces bracket failure and warranty claims over a multi-year deployment cycle.
  • HES Electromagnetic Lock Compatibility: The AM3305 is engineered specifically for HES maglock systems, ensuring proper alignment, load transfer, and electrical integration. Mixing brackets across vendors often introduces subtle misalignment that degrades lock engagement and increases nuisance failures in production environments.
  • Standard Door Frame Integration: These brackets mount to conventional commercial door frame configurations without requiring frame modification or custom fabrication. This compatibility streamlines installation timelines and reduces labor cost on multi-door projects.
  • Secure Load Path: The bracket design distributes maglock holding force across the frame structure, preventing stress concentration that could eventually compromise frame integrity or cause creep under sustained load.
  • Durable Performance in Demanding Environments: Industrial-grade construction resists corrosion, vibration, and wear from repeated door cycles. A bracket that holds up in a high-traffic office lobby or warehouse entry point pays for itself in reduced maintenance callbacks.

Integration & Compatibility

The HES AM3305 brackets mount directly to access control electromagnetic lock systems from the HES product line. When specifying a maglock system for a new installation or retrofit, confirm that the maglock unit itself is compatible with standard door frame geometry at your sites — some narrow or non-standard frames may require evaluation before ordering. These brackets are passive mechanical components; they do not directly interface with control wiring or power distribution, but proper installation is critical to ensure the maglock can generate full holding force without slippage or frame stress.

Deployment Scenarios

The AM3305 is suited for office buildings, educational facilities, healthcare institutions, and commercial properties where maglocks control main entry points, secure corridors, or restricted access doors. Any deployment that requires reliable, tamper-resistant access control on standard door frames is a candidate. High-volume environments with multiple identical installations (such as chain locations or campus-wide access control rollouts) benefit from standardizing on these brackets to simplify procurement and reduce installation variation.

Installation Considerations

Door frame preparation and alignment are essential. Brackets must be mounted perpendicular to the door face and frame, and the maglock itself must be positioned so the holding armature is flush with the strike during engagement. Improper alignment is the leading cause of maglock performance issues. Coordinate with the installer to verify frame dimensions and condition before ordering — warped or severely corroded frames may require reinforcement or replacement prior to bracket installation. Electrical connections to the maglock and control circuit are made separately; these brackets are structural only.

Frequently Asked Questions

Q: Can the HES AM3305 brackets be used with non-HES maglocks?

A: These brackets are engineered specifically for HES electromagnetic lock systems. Compatibility with other brands should not be assumed. Verify maglock model and mounting geometry with the manufacturer before substituting brackets.

Q: What is the typical installation time for the AM3305 brackets?

A: Installation time depends on frame condition and alignment. A standard door retrofit typically takes 1–2 hours per opening, including bracket positioning, fastening, and maglock mounting. Complex or non-standard frames may require longer.

Q: Do these brackets require maintenance?

A: Periodic inspection for corrosion, loose fasteners, and frame stress is recommended, especially in coastal or high-humidity environments. Industrial-grade brackets are corrosion-resistant but not immune; a visual check every 12–24 months is good practice.

Q: Are the AM3305 brackets suitable for outdoor door installations?

A: The brackets themselves are industrial-grade, but outdoor installations expose the maglock and control electronics to weather. Ensure the maglock enclosure is rated for outdoor use and that all power connections are weatherproofed and properly drained.

Q: What fastening methods are used for door frame mounting?

A: The AM3305 uses standard mechanical fasteners suitable for metal or wood door frames. Verify frame material and fastener availability at your site before installation.

Jerry Tildsen
Jerry Tildsen
Perspective based on aggregated IP Security Depot and affiliated engineering team experience.

The HES AM3305 is a straightforward mechanical component, but that simplicity masks a critical decision point. Get the bracket spec right at design time, or you'll be troubleshooting misalignment and nuisance failures across a deployed base. Industrial-grade construction isn't marketing speak here — it means tolerances are tight, fasteners are corrosion-resistant, and the bracket won't flex or creep under sustained maglock holding load. That matters in a 24/7 access control environment.

Technical Highlights:

  • HES-Specific Engineering: These brackets are tuned for HES maglock geometry. Substituting a generic bracket introduces alignment uncertainty. Proper alignment is the single largest factor in maglock reliability — a misaligned armature generates friction, wear, and eventual failure. The AM3305 eliminates that variable.
  • Industrial-Grade Material Selection: Brackets built to withstand vibration, thermal cycling, and corrosion in high-traffic commercial environments. This directly reduces warranty callbacks and lifecycle cost over a 5–10 year deployment.
  • Standard Frame Compatibility: No custom fabrication required for typical commercial door frames. This accelerates installation and scales across multi-location rollouts.

Deployment Considerations:

  • Frame alignment is not forgiving. Installers must verify that the door frame is square and that bracket mounting surfaces are parallel to the door face. Warped frames are the enemy here and often aren't caught until the maglock is live.
  • These brackets are structural only — they have no electrical function. Power and control wiring to the maglock are separate. Don't let an installer claim a bracket problem when the real issue is a wiring fault or failed coil.
  • In outdoor or corrosive environments, inspect fasteners and bracket surfaces annually. Salt spray, humidity, and thermal stress can degrade even industrial-grade finishes over time.

The AM3305 is the right choice for any commercial access control retrofit or new build that standardizes on HES maglocks and needs a proven, no-surprises mounting solution. It's not glamorous, but reliability in the access control layer is exactly what separates a well-run facility from one that's constantly fielding door complaints.

Specifications
Compatible With: HES electromagnetic lock systems
Form Factor: Mounting brackets
Application: Door access control
Weight: 0.25 lb
Country of Origin: US
Strike Type: Magnetic Lock
Product Type: Lock/Strike
Q&A
Reviews
Have Questions? Ask an Expert.

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources