Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: GXT5LI-2000LVRT2UXL
UPC: 767041034905
Condition: New
Write a Review 37% OFF

Vertiv GXT5 Lithium-ion 2000VA UPS 120VAC 2U Rack/tower - Lowest Total Cost - GXT5LI-2000LVRT2UXL

Vertiv GXT5LI-2000LVRT2UXL 2000VA Lithium-Ion Online Double-Conversion UPS, 2U Rack/TowerOverviewThe Vertiv GXT5LI-2000LVRT2UXL is a 2000VA / 1800W on…

$5,049.00 $3,187.99 SAVE $1861
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Vertiv GXT5 Lithium-ion 2000VA UPS 120VAC 2U Rack/tower - Lowest Total Cost - GXT5LI-2000LVRT2UXL

$5,049.00
$3,187.99

Overview

SKU: GXT5LI-2000LVRT2UXL
UPC: 767041034905
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GXT5LI-2000LVRT2UXL 2000VA Lithium-Ion Online Double-Conversion UPS, 2U Rack/Tower

Overview

The Vertiv GXT5LI-2000LVRT2UXL is a 2000VA / 1800W online double-conversion UPS built around a lithium-ion battery platform — a meaningful upgrade over traditional VRLA-based units for anyone tired of scheduling battery replacements every three to four years. At 2U rack height, it fits cleanly into standard 19-inch server racks or deploys freestanding in a tower orientation, with a gravity-sensing LCD that flips its display automatically depending on how the unit is installed. If you're protecting a small NVR stack, a network closet, or a security head-end that can't afford unplanned downtime, the GXT5LI-2000LVRT2UXL belongs on your shortlist.

For a deeper look at the Vertiv UPS and power protection line, including larger VA ratings and extended-runtime models, the brand catalog covers the full range of Liebert products.

Key Features

  • 2000VA / 1800W Online Double-Conversion: True online topology means incoming AC is continuously converted to DC and back — zero transfer time to battery when utility power fails. For NVRs and security servers that can't tolerate even a 4ms switchover gap, this matters. VRLA standby units with 4–8ms transfer windows can still cause HDD write errors or VMS session drops.
  • Lithium-Ion Battery Chemistry: Li-Ion cells typically deliver three to four times the cycle life of sealed lead-acid and operate across a wider temperature range. For rack deployments where the UPS is expected to run for a decade without a battery swap, this reduces total cost of ownership substantially — especially in remote or unmanned sites where a technician dispatch costs more than the battery itself.
  • 98% Efficiency in Active ECO Mode: In Active ECO Mode, efficiency climbs to 98%, cutting heat output and electricity draw. Even in full online double-conversion mode, the unit achieves up to 92% efficiency — better than many older transformer-based online UPS designs that run in the low-to-mid 80s. On a UPS running 24/7/365, those percentage points show up on the electric bill.
  • User-Configurable Output Voltage (100/110/115/120/125VAC): Output voltage is selectable from the front panel, which matters if you're deploying equipment rated for 100V or 110V markets alongside standard 120V North American gear — no additional transformer required.
  • Wide Input Voltage Window (60–150 VAC max): The unit accepts input from 60 to 150 VAC at maximum range, with nominal full-load operation from 102 to 150 VAC. That wide acceptance window keeps the unit on utility power through most brown-brown conditions without switching to battery unnecessarily — extending battery life in environments with chronic voltage sag.
  • 7 Output Receptacles — 6× 5-15/20R + 1× L5-20R: Six NEMA 5-15/20R outlets handle standard three-prong loads; the L5-20R twist-lock adds a hardwired, vibration-resistant connection point for your most critical device — typically the NVR, firewall, or primary switch. Input is L5-20P. Plan your cable inventory before deployment.
  • Color Graphic LCD with Gravity-Sensing Orientation: The display automatically detects whether the unit is rack-mounted or tower-oriented and rotates the interface accordingly. No menu-diving to flip the display — it just works. Useful in mixed installations where a UPS might be repositioned between rack and desktop depending on the site.
  • Intellislot Bay for Network Management Cards: The Intellislot expansion slot accepts optional management cards — most notably the Vertiv Liebert IntelliSlot RDU120 — enabling full SNMP and web-based remote monitoring. Without a card installed, you still get USB and RS-232 for local management and dry-contact terminal block for relay-based integration with building management systems. For network infrastructure deployments where UPS monitoring feeds into a DCIM or BMS platform, plan the card budget upfront.
  • UL 1778 / UL 1973 / UL 1642 / Energy Star 2.0 Listed: UL 1778 covers UPS safety; UL 1973 adds specific lithium battery system requirements; UL 1642 covers the cells themselves. Energy Star 2.0 qualification is relevant for government and enterprise procurement that mandates efficiency certifications. RoHS, WEEE, and REACH compliance covers EU regulatory requirements if this unit is part of a cross-border deployment.

Integration & Compatibility

The GXT5LI-2000LVRT2UXL integrates with monitoring infrastructure via USB or RS-232 for local UPS management software (compatible with most major UPS management platforms that support standard USB HID or serial communication). For network-level monitoring and SNMP alerting, the optional Vertiv Liebert IntelliSlot RDU120 network card installs into the rear Intellislot bay — this is a separate purchase. The dry-contact terminal block enables integration with access control and building management systems via relay outputs, useful for triggering alarms or automated shutdown sequences tied to UPS state changes.

Operating temperature is rated 32°F to 104°F (0°C to 40°C) with a 10% derating at 50°C — confirm your rack or closet environment stays within this range before deployment. Lithium-ion chemistry is more tolerant of temperature extremes than VRLA but still has limits. At 39.7 lbs, the unit is manageable for a two-person rack mount without a lift, though the 18.7-inch depth requires a mid-depth or full-depth rack.

Frequently Asked Questions

Q: What is the runtime on the GXT5LI-2000LVRT2UXL at full load?

A: Runtime at full 1800W load is not specified in the available technical documentation. Lithium-ion UPS runtime varies significantly by battery configuration and load percentage — consult the Vertiv runtime curves for this model or contact pre-sales engineering for a runtime estimate at your expected load.

Q: Does the GXT5LI-2000LVRT2UXL include a network management card?

A: No. The unit ships with an Intellislot bay that accepts optional management cards such as the Vertiv Liebert IntelliSlot RDU120 for SNMP and web-based remote monitoring. The card is a separate purchase. USB and RS-232 ports are included for local management without a card.

Q: Can the GXT5LI-2000LVRT2UXL be used in tower orientation?

A: Yes. This model supports both 2U rack-mount and tower/desktop orientations. The color graphic LCD includes gravity-sensing orientation detection and automatically rotates the display to match how the unit is installed.

Q: What input plug type does the GXT5LI-2000LVRT2UXL use?

A: The unit uses an L5-20P input connector (NEMA twist-lock, 20A, 120V). Ensure your PDU or wall outlet provides a compatible L5-20R receptacle. The six standard output receptacles are NEMA 5-15/20R; one hardwired output is L5-20R twist-lock.

Q: Is the GXT5LI-2000LVRT2UXL Energy Star certified?

A: Yes. The GXT5LI-2000LVRT2UXL carries an Energy Star 2.0 listing, along with UL 1778, UL 1973, UL 1642, RoHS, WEEE, and REACH compliance per the manufacturer's published specifications.

Q: What output voltage options are available on the GXT5LI-2000LVRT2UXL?

A: Output voltage is user-configurable from the unit's front panel: 100V, 110V, 115V, 120V, or 125VAC. This makes the unit compatible with mixed-voltage equipment without requiring an external transformer.

Specifications
Weight: 39.7 lbs
Height: 3.4 in
Width: 16.9 in
Depth: 18.7 in
Operating Temp: 32°F to 104°F (0°C to 40°C) (10% Derating at 50°C)
Power Rating: 2000VA / 1800W
Input Voltage Range: Nominal (Full Load): 102-150 VAC; Max: 60-150 VAC
Output Voltage Range: 120V; 100/110/115/120V/125VAC (User-Configurable)
Efficiency: Up to 92% in online mode; 98% in Active ECO Mode
Wiring: Input: L5-20P; Output: (6) 5-15/20R & (1) L5-20R
Interface Options: USB, RS232, Dry-Contact Terminal Block, Intellislot (for Management Cards)
Protocols: USB, Serial for Out-of-Band Management, SNMP/Web Management (w/ optional Vertiv™ Liebert® IntelliSlot™ RDU120 Network Card)
Control Panel: Color graphic LCD with gravity sensing orientation
Operating Temperature: 32°F to 104°F (0°C to 40°C) (10% Derating at 50°C)
Listings: UL 1778, UL 1973, UL 1642, Energy Star 2.0, RoHS, WEEE, REACH
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources