APC by Schneider Electric Galaxy vs Classic Battery Cabinet UL Type 6 Seismic Tested - GVSCBT6ST

APC by Schneider Electric GVSCBT6ST Galaxy VS Classic Battery CabinetOverviewThe GVSCBT6ST is APC by Schneider Electric's Galaxy VS Classic Battery Ca…

$62,665.00 $41,993.99 SAVE $20671
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Galaxy vs Classic Battery Cabinet UL Type 6 Seismic Tested - GVSCBT6ST

$62,665.00
$41,993.99

Overview

SKU: GVSCBT6ST
UPC: 731304406471
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVSCBT6ST Galaxy VS Classic Battery Cabinet

Overview

The GVSCBT6ST is APC by Schneider Electric's Galaxy VS Classic Battery Cabinet — a tower-format, sealed lead-acid (VRLA) external battery enclosure engineered to extend runtime on Galaxy VS UPS systems in demanding commercial and industrial environments. At 1,127 mm wide, 840 mm deep, and 1,485 mm tall, this is a substantial floor-standing cabinet designed to house additional battery strings where single-cabinet runtime falls short of your uptime SLA. The UL listing and factory-verified seismic testing make it a realistic option for data centers and critical infrastructure sites in seismic zones, not just a paper checkbox. If you're sizing a power continuity plan for a network room, edge compute site, or industrial control environment and your Galaxy VS runtime calculations come up short, the GVSCBT6ST is the purpose-built expansion path.

Key Features

  • Sealed Lead Acid (VRLA) Battery Technology: Valve-regulated lead acid chemistry requires no water maintenance and can be deployed in enclosed equipment rooms without special ventilation provisions — a practical advantage over flooded cell alternatives in IT and commercial spaces.
  • Tower Form Factor (1,127 mm × 840 mm × 1,485 mm): The freestanding tower profile means this cabinet installs alongside Galaxy VS UPS units on the data floor rather than consuming rack space. At roughly 44 inches wide and 58 inches tall, plan floor space and cable routing before delivery — this is not a unit you'll be rearranging after installation.
  • UL Listing: UL certification is a hard requirement for many facilities, including healthcare, government, and any site with an Authority Having Jurisdiction (AHJ) review. The GVSCBT6ST satisfies that requirement without requiring field certification waivers.
  • Seismic Tested (Type 6): Seismic testing to Type 6 classification means the cabinet has been validated to remain structurally intact during zone-appropriate seismic events. For sites in California, the Pacific Northwest, or anywhere OSHPD or IBC seismic provisions apply, this matters at the permit stage. Most battery cabinets skip this testing entirely.
  • Operating Temperature Range 0–40°C: Standard commercial HVAC environments are well within spec. This is not rated for outdoor or industrial extremes — keep ambient temps below 40°C to avoid accelerating VRLA battery degradation, which compounds with every degree above optimal.
  • Storage Temperature Range -15–40°C: The wider storage window (-15°C to 40°C) gives flexibility during staging and warehousing, but commission the system promptly once received — VRLA batteries self-discharge during extended storage and will require conditioning before deployment.
  • White Tower Finish: The white enclosure aligns with Galaxy VS UPS aesthetics for deployments where visual consistency in the equipment room is a facility requirement.

Integration and Compatibility

The GVSCBT6ST is designed as an external battery cabinet for the APC by Schneider Electric Galaxy VS UPS platform. Compatibility is model-specific — verify the exact Galaxy VS UPS variant against APC's battery cabinet compatibility matrix before ordering. Mixing battery cabinet types or connecting to non-compatible UPS models is not supported and risks both equipment damage and warranty issues. For UPS and power continuity planning, work from the Galaxy VS runtime extension documentation to determine how many GVSCBT6ST cabinets your load and runtime targets require. Installation involves inter-cabinet cabling and may require a qualified electrician depending on local code; review the battery cabinet installation requirements for your specific Galaxy VS model before scheduling the install. If your project requires a UPS runtime extension strategy, confirm total string count and cabinet sequencing with pre-sales engineering before committing to a configuration.

Frequently Asked Questions

Q: What UPS systems is the GVSCBT6ST compatible with?

A: The GVSCBT6ST is designed for the APC Galaxy VS UPS platform. Compatibility is model-specific — confirm the exact Galaxy VS model number against APC's published compatibility matrix before ordering to ensure correct electrical and mechanical fit.

Q: Is the GVSCBT6ST seismic certified, and what does Type 6 mean?

A: Yes. The GVSCBT6ST has been seismic tested to Type 6 classification, meaning it has been validated to remain structurally intact under seismic loading conditions appropriate to that type designation. This is relevant for sites subject to IBC, OSHPD, or similar seismic code requirements. Verify that Type 6 meets the specific seismic zone requirements for your facility with your AHJ.

Q: What battery technology does the GVSCBT6ST use?

A: It uses Sealed Lead Acid (VRLA) batteries. VRLA batteries are valve-regulated and maintenance-free under normal operating conditions — no water addition required. Keep operating temperatures within the 0–40°C rated range to maximize battery service life.

Q: What are the physical dimensions of the GVSCBT6ST?

A: The cabinet measures 1,127 mm wide × 840 mm deep × 1,485 mm tall (approximately 44.4 in × 33.1 in × 58.5 in) in tower configuration. Plan floor space, access clearances, and cable routing paths before delivery — the unit ships on a pallet and requires appropriate material handling equipment.

Q: Is the GVSCBT6ST UL listed?

A: Yes, the GVSCBT6ST carries a UL listing, which satisfies the certification requirement for most AHJ reviews in commercial, healthcare, and government facilities in the United States.

Q: What is the operating temperature range for the GVSCBT6ST?

A: The rated operating temperature range is 0°C to 40°C (32°F to 104°F). Operating above 40°C will accelerate VRLA battery aging. The storage temperature range is -15°C to 40°C, providing flexibility during staging and logistics.

Ted Perry
Ted Perry

When I look at the GVSCBT6ST, the spec that matters most in practice is the seismic Type 6 testing — not because most buyers are in earthquake country, but because it's the single certification that separates a battery cabinet that will pass an AHJ review from one that won't, and that conversation happens after the equipment is already on-site. If you're deploying Galaxy VS in California, Oregon, Washington, or any federal or healthcare facility with IBC seismic provisions, the GVSCBT6ST needs to be on your BOM from day one, not added after the permit review comes back rejected.

Technical Highlights:

  • VRLA Battery Chemistry: Sealed lead acid construction eliminates the maintenance overhead and ventilation requirements of flooded cell batteries — deploy this in a standard IT equipment room without special exhaust provisions.
  • UL Listing: Satisfies the hard certification requirement for commercial, healthcare, and government AHJ reviews in the US without field certification or waivers.
  • Operating Envelope (0–40°C): Standard commercial HVAC keeps you well within spec, but this is a firm ceiling — VRLA battery degradation accelerates non-linearly above 40°C, shortening the service interval significantly.

Deployment Considerations:

  • The tower footprint (1,127 mm × 840 mm × 1,485 mm) is substantial — confirm floor load ratings and cable run distances to the Galaxy VS UPS before the unit arrives. Last-minute repositioning of a fully loaded battery cabinet is not practical.
  • VRLA batteries self-discharge during storage; if the cabinet sits in staging for more than a few weeks before commissioning, budget time for a conditioning charge cycle before putting it on-load.

The GVSCBT6ST is the right call for Galaxy VS runtime extension in seismically regulated facilities — data centers, hospital generator backup rooms, and government edge sites where the UL listing and seismic Type 6 classification are non-negotiable permit requirements, not optional credentials.

Specifications
Form factor: Tower
Product colour: White
Battery technology: Sealed Lead Acid (VRLA)
Operating temperature (T-T: 0 - 40 °C
Storage temperature (T-T: -15 - 40 °C
Width: 1127 mm
Depth: 840 mm
Height: 1485 mm
Weight: 1622 kg
Quantity: 1
Package width: 1372 mm
Package depth: 998 mm
Package height: 1688 mm
Package weight: 1736.3 kg
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources