Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: GVMS225KGF65S
Condition: New
Write a Review 32% OFF

APC by Schneider Electric Galaxy VM 225 KVA UPS Single 480-208 V 65KAIC Start UP 5X8 - GVMS225KGF65S

APC by Schneider Electric GVMS225KGF65S Galaxy VM 225 KVA UPSThe APC by Schneider Electric GVMS225KGF65S is a Galaxy VM series three-phase uninterrupt…

$140,615.00 $95,643.99 SAVE $44971
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

APC by Schneider Electric Galaxy VM 225 KVA UPS Single 480-208 V 65KAIC Start UP 5X8 - GVMS225KGF65S

$140,615.00
$95,643.99

Overview

SKU: GVMS225KGF65S
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

APC by Schneider Electric GVMS225KGF65S Galaxy VM 225 KVA UPS

The APC by Schneider Electric GVMS225KGF65S is a Galaxy VM series three-phase uninterruptible power supply rated at 225 KVA, configured for single-feed 480 V input stepping down to 208 V output — a common configuration for data centers and large industrial facilities running mixed North American IT loads. The 65KAIC fault current rating means this unit is built for main distribution panels where available fault current is high, a critical consideration in commercial construction that underspecified UPS equipment often fails to meet. The package includes APC's 5x8 Start UP service, so a factory-trained technician commissions the unit during business hours — not a minor detail on a system of this size.

Key Features

  • 225 KVA Power Capacity: Sized for large server rooms, data halls, or critical manufacturing lines where a single UPS needs to carry dozens of high-draw loads simultaneously. At 225 KVA you're covering roughly 150-180 kW of real IT load at typical power factors — plan your load budget accordingly before spec'ing the distribution downstream.
  • Single 480-208V Feed Configuration: The 480 V utility input matches standard large commercial service entrance voltage, while the 208 V output feeds standard North American three-phase PDUs and IT panels directly — no additional step-down transformer required in most data center deployments, simplifying the single-line diagram.
  • 65KAIC Interrupting Capacity: This fault current rating satisfies NEC requirements for installation in panels with high available short-circuit current — typically required in facilities fed by large utility transformers or close to the service entrance. Specifying a UPS without verifying AIC against your panel's SCCR is how projects get rejected at inspection.
  • 5x8 Start UP Service Included: Factory commissioning during standard business hours is bundled at purchase, covering initial energization, bypass testing, and system verification. For a 225 KVA system, skipping professional startup introduces both warranty risk and operational liability — this service removes that variable.
  • Galaxy VM Platform: The Galaxy VM series is APC's three-phase UPS line for enterprise and industrial power protection, designed for integration with EcoStruxure IT for remote monitoring and DCIM platforms common in managed data center environments.

Integration and Compatibility

The GVMS225KGF65S is designed for integration into APC's EcoStruxure IT ecosystem, supporting centralized monitoring and management alongside other Schneider Electric UPS and power protection infrastructure. For installations requiring extended runtime, external battery cabinets from the Galaxy VM family can be paired with this unit. Consult your UPS selection and sizing guide to confirm load calculations, bypass requirements, and battery autonomy targets before finalizing the single-line design.

Frequently Asked Questions

Q: What input voltage does the GVMS225KGF65S require?

A: The GVMS225KGF65S is configured for a single 480 V input feed, outputting 208 V — standard for large commercial and data center electrical infrastructure in North America.

Q: What does the 65KAIC rating mean for installation?

A: KAIC (kilo-ampere interrupting capacity) indicates the maximum fault current the unit is rated to withstand. At 65KAIC, this UPS can be installed in panels with up to 65,000 amperes of available short-circuit current, satisfying NEC compliance in most commercial distribution environments.

Q: What is included in the 5x8 Start UP service?

A: The Start UP 5x8 service provides on-site commissioning by a factory-trained technician during standard business hours (5 days a week, 8 hours a day). It covers initial startup, functional testing, and system verification — required for warranty activation on systems of this class.

Q: Can the GVMS225KGF65S be expanded with external battery cabinets?

A: The Galaxy VM platform supports external battery cabinet expansion for extended runtime. Specific compatible cabinet models and maximum string configurations should be confirmed against APC's Galaxy VM product family documentation for this KVA rating.

Q: Is the GVMS225KGF65S suitable for a modular data center or prefabricated facility?

A: The Galaxy VM series is designed for integration into standard data center infrastructure including prefabricated and edge deployments. Confirm floor loading, ventilation clearances, and utility feed capacity with your facilities team before finalizing placement.

Marty Allison
Marty Allison

The spec that matters most on the GVMS225KGF65S before anything else is that 65KAIC interrupting capacity — I've seen projects stall at final inspection because the UPS was sized for load but not for fault current at the point of installation. On a 225 KVA system fed from a large utility transformer close to the service entrance, available fault current routinely exceeds what lower-rated equipment can handle. This unit is spec'd to address that.

Technical Highlights:

  • 225 KVA / 480-208V: Covers large IT loads on standard North American three-phase infrastructure without an intervening step-down transformer — simplifies the single-line and reduces points of failure.
  • 65KAIC Fault Rating: Meets NEC requirements for high-fault-current distribution environments; necessary for main-panel-adjacent installations in commercial and industrial facilities.
  • 5x8 Start UP Service: Bundled commissioning removes a common warranty gap — systems of this size need documented professional startup to activate coverage and confirm protection scheme operation.

Deployment Considerations:

  • Verify floor loading capacity before placement — a 225 KVA UPS with internal batteries will exceed 1,000 kg in most configurations; raised-floor data centers need point-load analysis.
  • The 5x8 service window means commissioning is scheduled during business hours only; if your go-live requires weekend or after-hours startup, confirm whether an upgrade to a higher service tier is available separately.

The GVMS225KGF65S is a strong fit for a 225 KVA critical power node in a mid-to-large data center, a large hospital plant room, or a manufacturing facility running high-density automation loads on 480 V utility feeds — anywhere the fault current environment rules out lighter-rated alternatives.

Specifications
Mfr: GVMS225KGF65S
Unspsc: 43211600
Item: 003392717
Cnet Cat Code: 100616
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources