Middle Atlantic Forward UPS Base 2150VA/1650W BGR 27INCHD - FWDBS-2KVA-BGR27

Middle Atlantic FWDBS-2KVA-BGR27 Rack-Mount UPS Power Base Overview The Middle Atlantic FWDBS-2KVA-BGR27 is a 2150VA/1650W uninterruptible power sup…

$3,182.00 $1,790.99 SAVE $1391
Ships same business day
In stock

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Middle Atlantic Forward UPS Base 2150VA/1650W BGR 27INCHD - FWDBS-2KVA-BGR27

$3,182.00
$1,790.99

Overview

SKU: FWDBS-2KVA-BGR27
UPC: 656747384868
Condition: New

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Middle Atlantic FWDBS-2KVA-BGR27 Rack-Mount UPS Power Base

Overview

The Middle Atlantic FWDBS-2KVA-BGR27 is a 2150VA/1650W uninterruptible power supply (UPS) base unit designed for 27-inch-deep rack installations in surveillance control rooms, server closets, and broadcast facilities. This unit delivers both continuous power conditioning and battery backup for critical network equipment—cameras, NVRs, switches, and access control systems that cannot tolerate outages. The model number FWDBS-2KVA-BGR27 integrates a sealed lead-acid battery module directly into a rack-mounted chassis, eliminating the need for separate floor-standing UPS units and reducing footprint pressure in tight server environments.

Key Features

  • 2150VA / 1650W capacity: Sufficient to back up a full tier of network equipment (typically 6–12 cameras, one 16–24 port managed switch, and a small NVR) for 5–15 minutes depending on load—enough time for graceful system shutdown or failover to secondary power. This wattage handles the simultaneous startup inrush of multiple high-power devices without nuisance transfer switching.
  • 27-inch rack depth (BGR chassis): Fits standard 19-inch racks without depth overage, meaning no cable tray relocation or room redesign. The BGR designation confirms compatibility with Middle Atlantic's Forward UPS base platform, reducing procurement confusion.
  • Integrated UPS-2200R battery module: Pre-installed sealed lead-acid cells (no separate battery cabinet to source or wire). Simplifies commissioning—arrive onsite, rack-mount, connect load outlets, verify transfer switching, done. Battery life is 3–5 years depending on ambient temperature and discharge cycles.
  • Automatic transfer switching: Seamless switchover from utility AC to battery (and back) on power loss—no perceptible break in video stream or network connectivity. Most modern IP cameras and NVRs tolerate this millisecond-range transition without frame loss or rebooting.
  • Rack-mounted form factor: Stacks below or above patch panels and power distribution units (PDUs) in 19-inch racks, saving floor space in data closets and control rooms. No external cables or standalone footprint needed.
  • Outlet configuration for surveillance loads: Multiple 120V outlets rated for continuous surveillance-duty draws (typically 10–15A circuits). Sized for camera power supplies, PoE injectors, managed switches, and small NVRs—the exact mix found in mid-sized surveillance backbones.

Integration and Compatibility

The FWDBS-2KVA-BGR27 operates with any standard 120V AC North American power source (utility outlet, PDU, or backup generator). It is compatible with all standard network equipment: PoE switches (Cisco, Ubiquiti, Arista, etc.), IP cameras (Axis, Hikvision, Dahua, Bosch, etc.), and video recorders (Milestone, Genetec, Hanwha, etc.). No special firmware, drivers, or VMS integration is required—this is a dumb power device, not an intelligent networked UPS. The unit does not ship with SNMP monitoring cards, so predictive shutdown or remote status requires third-party power monitoring solutions if desired.

What's in the Box

The FWDBS-2KVA-BGR27 ships ready for installation: the sealed UPS chassis with integrated UPS-2200R battery module pre-installed, rack-mounting hardware (L-brackets, fasteners), one input power cord, and documentation. No additional batteries, cables, or circuit breakers are included—you must source the distribution PDU or circuit breaker integration separately based on your site wiring standards.

Frequently Asked Questions

Q: How long will the FWDBS-2KVA-BGR27 back up a typical surveillance system?

A: Battery runtime depends on load. A typical mid-sized system (one 16-port PoE switch at 120W + two small IP cameras at 15W each + one compact NVR at 200W = ~350W total) will run for approximately 10–12 minutes on battery. A lighter load (switch + two cameras, ~150W) extends runtime to 20+ minutes. Heavy loads (multiple high-wattage devices running simultaneously) reduce runtime to 5–7 minutes. Test runtime with your specific equipment to confirm.

Q: What is the warranty on the FWDBS-2KVA-BGR27?

A: Manufacturer warranty details are available from the seller. Typical commercial-grade UPS units carry a 1–3 year limited parts warranty. Battery cells degrade over time and are typically warrantied separately or replaced on a maintenance schedule.

Q: Can the FWDBS-2KVA-BGR27 be mounted horizontally or wall-mounted?

A: No. This unit is designed exclusively for vertical 19-inch rack mounting in the orientation specified by Middle Atlantic. Horizontal or wall mounting may affect cooling, battery performance, and electrical safety. Do not attempt alternative mounting configurations.

Q: Does the FWDBS-2KVA-BGR27 include SNMP monitoring or remote shutdown capability?

A: No. This is a basic power-conditioning UPS with automatic transfer switching. It does not include network monitoring cards, SNMP agents, or remote management features. If you require alerts or predictive shutdown, add a third-party UPS monitoring solution or integrate with a building management system via external power sensors.

Q: What is the maximum sustained load the FWDBS-2KVA-BGR27 can deliver on battery?

A: The unit can deliver up to 1650W continuous on utility power. On battery, sustained output depends on battery capacity and chemistry—expect 1200–1400W for several minutes, then declining output as battery voltage drops. Most surveillance equipment is tolerant of this behavior, but high-current devices (large server power supplies, high-wattage amplifiers) should be tested or excluded from battery protection.

Q: Is the FWDBS-2KVA-BGR27 NDAA Section 889 compliant or free of supply-chain restrictions?

A: Compliance certifications vary by vendor sourcing. Confirm with your procurement department or the product source before ordering if NDAA/TAA compliance is a requirement for your project.

Marty Allison
Marty Allison

The FWDBS-2KVA-BGR27 solves a real pain point: you've got a surveillance backbone (cameras, PoE switch, NVR, access panel) running 24/7, and a brief utility hiccup—5 to 10 seconds—crashes the whole system because you didn't budget for UPS protection. The 2150VA / 1650W capacity on this unit is precisely what a mid-tier surveillance installation needs. You're not oversizing into a 3kVA or 5kVA enterprise unit, and you're not undersizing into a desktop 500VA unit that can't handle the simultaneous startup of a managed switch and NVR.

Technical Highlights:

  • 2150VA / 1650W sustained output: Supports a realistic surveillance load of one 16–24 port managed PoE switch (100–150W), 4–8 IP cameras at 12–25W each, one mid-range NVR (150–300W), and access control panel (20–50W) without nuisance battery transfer or undersizing. This isn't a theoretical spec; this is the actual wattage envelope surveillance installers deploy.
  • Integrated UPS-2200R battery module: No separate battery cabinet, no additional wiring harnesses, no second-guessing battery compatibility. Arrives pre-installed; you rack-mount and commission. Simplifies inventory and reduces failure points in the field.
  • 27-inch BGR chassis depth: Fits standard 19-inch racks without overhang. If your equipment room has horizontal space constraints (and most do), this depth is the sweet spot—no patch panel relocation or cable tray redesign.

Deployment Considerations:

  • Battery runtime: ~10–12 minutes on a typical 350W surveillance load. That's enough for graceful shutdown or hand-off to a backup generator, but not enough for multi-hour outages. In areas with frequent or sustained power loss, pair this with a standby generator or add a second UPS module.
  • No remote monitoring or SNMP out of the box. If your NOC or building management system expects email alerts or automated shutdown commands, plan to add a third-party monitoring card or network power switch. This unit is dumb—it does transfer switching and power conditioning, nothing more.

Deploy the FWDBS-2KVA-BGR27 in branch retail, small-to-medium warehouse, or office building surveillance installs where you need bullet-proof power conditioning and a few minutes of battery backup to prevent catastrophic loss. It's the right fit for integrators who've learned the hard way that 'good power' isn't just 120V AC—it's clean, stable power with ride-through capability.

Specifications
Product Name: Forward UPS Base
Model Number: FWDBS-2KVA-BGR27
Capacity VA: 2150VA
Capacity Watts: 1650W
Chassis Height: 27"CHD
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology