Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Server Technology C4G36RA-5CBD2FE1 415V Switched POPS Rack PDU

Overview

The Server Technology C4G36RA-5CBD2FE1 is a 415V, 17.3kW switched rack PDU built for data center and colocation racks that need outlet-level power visibility, not just a total load reading. It combines Per-Outlet Power Sensing (POPS) with Per-Inlet Power Sensing (PIPS) so you get current, voltage, power, apparent power, crest factor, power factor, and energy data at both the whole-unit and individual-outlet level. This is a vertical zero-U form factor at 70 inches tall, 2.2 inches wide, and 2.5 inches deep — designed to mount in the rear channel of a rack cabinet without eating into usable U-space for servers or switches. C4G36RA-5CBD2FE1 (often searched as C4G36RA 5CBD2FE1) is positioned for hyperscale, colocation, and high-density edge deployments where 415V three-phase distribution is already in place.

Key Features

  • 17.3kW input power capacity at 415V: supports high-density rack loads — GPU clusters, blade chassis, dense compute — without needing a second PDU in the same cabinet.
  • NEMA L22-30P input plug, 30A input current, 24A rated: a locking three-phase plug that won't back out under vibration, with the 24A continuous rating giving you the headroom NEC 80% derating requires for a 30A circuit.
  • 36 total outlets — 12x C13 and 24x HDOT Cx: the Cx outlets are UL-tested hybrids that physically accept either a C14 or C20 plug, so you're not stuck reordering PDUs when a server ships with a C19/C20 power cord instead of the standard C13/C14.
  • Outlet ratings up to 16A @ 208V L-N (20A peak) on Cx, 12A @ 208V L-N (15A peak) on C13: gives you real per-outlet headroom for mixed loads — small switches on C13, higher-draw servers or storage arrays on Cx — on the same strip.
  • Six branch circuit breakers, UL489 2-pole 20A trip, 10 kAIC interrupt rating: a fault on one outlet group trips its own breaker instead of taking down the whole PDU, which matters when you've got dozens of servers hanging off a single unit.
  • Per-Outlet Power Sensing (POPS): per-outlet current, voltage, power, VA, crest factor, power factor, and energy — the data you need to right-size circuits and catch a single misbehaving PSU before it trips a breaker.
  • Per-Inlet Power Sensing (PIPS): the same measurement set at the inlet level, useful for capacity planning across the whole rack rather than outlet-by-outlet.
  • Input and output measurement accuracy of ±0.2% for both voltage and current: tight enough for real capacity billing and power-budget planning in colocation environments, not just rough load estimates.
  • Hot-swappable controller: the controller — housing compute, display, and connectivity — can be replaced without powering down the outlets it manages, so a controller fault doesn't force a rack outage.
  • 45-degree angled infeed: improves cable routing and strain relief in tight rear-of-rack spaces, and the bend radius is rated for 60A cords if you're standardizing infeed cabling across a row.
  • Multi-unit linking and cascading, up to 16 PDUs on one IP: cuts down on IP address consumption and management overhead when you're running a full row of racks off this PDU family.
  • Environmental monitoring for up to 12 daisy-chained DX2 SmartSensors: lets you tie temperature/humidity alerting into the same management interface as your power data, with SNMP alerts and email notifications.

Integration & Compatibility

Network access runs over 10/100/1000 Mbps Ethernet or 802.11 a/b/g/n Wi-Fi, with management through HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), or RS-232 serial — enough protocol coverage to fit into most existing DCIM or monitoring stacks without a proprietary agent. A 5V/500mA USB output is available for auxiliary peripherals at the rack. The unit is rated for operation from 32°F to 140°F (0°C to 60°C) at 5%–90% RH non-condensing, with storage tolerance down to -40°F and up to 185°F — a wide enough band for most conditioned data center floors as well as less-controlled edge and telecom cabinets. Certifications include UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Subpart B Class A, and CAN ICES-003 Class A. For the rest of the rack, pair this PDU with rack-mount NVRs or compute drawing from the same 415V circuit, and review a PoE and power planning guide before finalizing circuit assignments across a multi-PDU row. Browse the full Server Technology PDU catalog for lower-capacity or single-phase variants if 415V three-phase isn't available at your site, and check the power distribution units category for outlet configurations better suited to lower-density racks. A companion rack accessory lineup covers cable management for the angled infeed if you're standardizing a full row.

Frequently Asked Questions

Q: What input voltage and plug does the C4G36RA-5CBD2FE1 use?

A: It's a 415V PDU with a NEMA L22-30P input plug, rated for 30A input current (24A continuous rated) and 17.3kW input capacity.

Q: How many outlets does the C4G36RA-5CBD2FE1 have and what type?

A: 36 total outlets — 12x C13 and 24x HDOT Cx (a hybrid outlet that accepts both C14 and C20 plugs).

Q: Does the C4G36RA-5CBD2FE1 provide per-outlet power monitoring?

A: Yes. It includes Per-Outlet Power Sensing (POPS) and Per-Inlet Power Sensing (PIPS), reporting current, voltage, power, apparent power, crest factor, power factor, and energy, with ±0.2% measurement accuracy on both voltage and current.

Q: Can the C4G36RA-5CBD2FE1 be managed remotely?

A: Yes. It supports 10/100/1000 Mbps Ethernet and 802.11 a/b/g/n Wi-Fi connectivity, with management via HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), and RS-232 serial.

Q: What are the operating temperature limits for the C4G36RA-5CBD2FE1?

A: 32°F to 140°F (0°C to 60°C) at 5%–90% RH non-condensing during operation; storage range extends to -40°F to 185°F.

Q: Can multiple C4G36RA-5CBD2FE1 units be linked together?

A: Yes. Up to 16 PDUs can be daisy-chained from a primary unit over USB or Ethernet and managed through a single IP address.

Jerry Tildsen
Jerry Tildsen

The number that jumps out on the C4G36RA-5CBD2FE1 is the 17.3kW capacity off a 415V, 30A NEMA L22-30P infeed — that's a real high-density rack PDU, not a repackaged single-phase strip. I spec this class of unit when a rack is pushing dense compute or GPU nodes and the site already has three-phase 415V distribution run to the row.

Technical Highlights:

  • 36 outlets (12x C13, 24x HDOT Cx): the Cx outlets accept both C14 and C20 cords, so you're not locked into a single power cord spec across a mixed rack of switches, servers, and storage.
  • POPS + PIPS metering at ±0.2% accuracy: that's tight enough to actually trust for capacity billing or power-budget audits, not just a rough load gauge.
  • Six UL489 branch breakers at 20A trip, 10 kAIC: outlet groups are fused independently, so one overloaded server doesn't take the whole PDU offline.

Deployment Considerations:

  • Confirm your site actually runs 415V three-phase to the rack before ordering — the NEMA L22-30P infeed won't adapt to a standard 208V single-phase drop.
  • At 70 inches tall and only 2.2 inches wide, this mounts in the rear vertical channel of the rack — check your cabinet's rear channel clearance against the 2.5-inch depth before ordering, especially in narrower colocation cabinets.

This is the right call for a colocation or hyperscale rack running dense, mixed-cord-type equipment on 415V power where you need outlet-level accountability for every device drawing from the C4G36RA-5CBD2FE1 — not a fit for a standard 120V/208V single-phase server room.

Specifications
Input Voltage: 415 V
Input Plug: NEMA L22-30P
Input Current: 30 A
Input Current Rated: 24 A
Input Power Capacity: 17.3 kW
Outlet Count C13: 12
Outlet Count Cx: 24
Outlet Rating C13:
Outlet Rating Cx:
Branch Circuit Protection: UL489 Compliant 2-pole, 20A trip circuit breakers, six (6) branch, rating:
Dimensions: 70.0in tall x 2.2in wide x 2.5in deep [1778mm x 56mm x 64mm]
Operating Temperature: 32°F to 140°F / 0°C to 60°C
Operating Humidity: 5% RH to 90% RH non-condensing
Storage Temperature: -40°F to 185°F / -40°C to 85°C
Storage Humidity: 20% RH to 90% RH non-condensing
Ethernet Speed: 10/100/1000 Mbps
Wi-Fi Standard: 802.11 a/b/g/n
USB Output: 5 V / 500 mA
Input Measurement Accuracy Voltage: +/- 0.2%
Input Measurement Accuracy Current: +/- 0.2%
Output Measurement Accuracy Voltage: +/- 0.2%
Output Measurement Accuracy Current: +/- 0.2%
Certifications: UL 62368-1, CSA C22.2 No. 62368-1, FCC Part 15 Subpart B Class A, CAN ICES-003 Class A
Brand: Server Technology
MPN: C4G36RA-5CBD2FE1
Q&A
Reviews

Server Technology FOR CC-E1-128 - C4G36RA-5CBD2FE1

$4,381.00
$4,179.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources