Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: FRY126SCLBL
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 35% OFF

Panduit FRY126SCLBL 12x4 Y-Reducer FiberRunner Cover

Panduit FRY126SCLBL 12x4 Y-Reducer FiberRunner Cover The Panduit FRY126SCLBL cover provides tool-free access to fiber pathways at 12x4 FiberRunner Y-r…

$242.46 $157.99 SAVE $84

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit FRY126SCLBL 12x4 Y-Reducer FiberRunner Cover

$242.46
$157.99

Overview

SKU: FRY126SCLBL
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit FRY126SCLBL 12x4 Y-Reducer FiberRunner Cover

The Panduit FRY126SCLBL cover provides tool-free access to fiber pathways at 12x4 FiberRunner Y-reducer junctions. Designed for high-density data centers and telecom central offices, this polycarbonate/ABS cover eliminates the need for screwdrivers or fastener removal during cable adds, moves, and changes. The 17.27-inch span bridges the transition zone where a single 12-inch raceway splits into dual 4-inch branches, maintaining physical protection while preserving instant access to the cable bundle underneath. UL-listed to 2024A and qualified to Telcordia GR-63-CORE with NEBS Level 3 compliance, this component meets the structural and flame-spread requirements for carrier-grade installations.

Key Features

  • Tool-free snap-on/snap-off design for rapid cable access during MACs without disrupting adjacent pathway sections
  • Polycarbonate/ABS blend delivers UL 94 flame rating and impact resistance for overhead routing in seismic zones
  • 17.27" W × 10.19" L × 2.79" H form factor spans 12x4 Y-reducer junction geometry with full fiber bundle coverage
  • NEBS Level 3 and Telcordia GR-63-CORE qualification for central office and carrier hotel deployments
  • Black finish integrates with standard FiberRunner pathway aesthetics in raised-floor and overhead ladder installations
  • UL 2024A certification for optical fiber cable routing assemblies in plenum and riser applications
  • RoHS-compliant construction meets procurement requirements for federal and enterprise data center projects

The FRY126SCLBL cover addresses a recurring pain point in structured fiber deployments: the need to access transition zones without removing fasteners or lifting entire raceway sections. Traditional screw-down covers require tools, create FOD risk from dropped hardware, and slow down troubleshooting during outage windows. Panduit's snap-fit retention system uses molded tabs that engage the Y-reducer base rail, allowing a single technician to lift the cover in under five seconds and reseat it with positive tactile feedback. The polycarbonate/ABS copolymer maintains dimensional stability across -40°F to 150°F operating ranges common in telecom equipment rooms and unheated MDF spaces. Material thickness and rib geometry provide a 10-pound distributed load rating, preventing deflection when technicians rest test equipment or cable spools on the closed pathway during installation. The black pigment resists UV degradation in skylight-exposed data halls and matches the FiberRunner system's standard finish, eliminating the patchwork appearance that results from mixing OEM and aftermarket components.

Deploy the FRY126SCLBL at fiber aggregation points where backbone OM3/OM4 trunks from equipment rows split into zone distribution legs. Typical installations include top-of-rack to end-of-row transitions in hyperscale facilities, central office FTTP splitter arrays, and broadcast facility router-to-MCR pathways. The 12x4 reducer geometry accommodates up to 864 fibers in high-density trunk cables entering the junction, then organizes them into two 432-fiber branch paths without exceeding the 1.5-inch minimum bend radius required by TIA-568. The 10.19-inch length provides enough working clearance to coil service loops at the split point, a critical requirement when pre-terminating breakout assemblies before final equipment placement is confirmed. In renovation projects where existing 12-inch FiberRunner pathways must feed new 4-inch drops to edge cabinets, this cover maintains the original pathway's plenum rating without requiring a complete teardown and replacement. Pair with Panduit's FRRC12BL-6 12-inch covers and FRRC4BL-6 4-inch covers to build continuous pathways that preserve tool-free access across the entire route.

UL 2024A listing qualifies the FRY126SCLBL for use in air-handling spaces above drop ceilings and within vertical riser shafts, satisfying AHJ requirements during permit reviews for new-construction and tenant-improvement projects. Telcordia GR-63-CORE compliance demonstrates the cover's ability to remain seated during Zone 4 seismic events (1.5g peak acceleration), preventing fiber exposure and crush damage when adjacent equipment racks shift during a tremor. NEBS Level 3 qualification extends this protection to include airborne particulate resistance and humidity cycling, ensuring long-term pathway integrity in carrier hotels and colocation facilities where environmental controls may be limited to equipment cages rather than the entire floor. The five-piece carton quantity aligns with typical row-length deployments in 42U cabinet arrays, reducing per-piece packaging waste and freight cost compared to individually boxed accessories. For integrators managing fiber infrastructure in mission-critical facilities, this cover transforms a traditionally rigid pathway system into a flexible access layer that adapts to the operational tempo of modern networks without sacrificing the physical protection and code compliance that distinguish permanent installation from temporary cabling.

Specifications
Product Type: Fiber Cable Routing Cover
Model Number: FRY126SCLBL
Product Line: FiberRunner
Application: Y-Reducer Junction Cover for 12x4 Transitions
Material: Polycarbonate/ABS Copolymer
Color: Black
Overall Width: 17.27 in (438.6 mm)
Overall Length: 10.19 in
Overall Height: 2.79 in (70.9 mm)
Installation Method: Tool-Free Snap-Fit
UL Listing: UL 2024A Optical Fiber Cable Raceway
NEBS Compliance: Level 3 Qualified
Telcordia Standard: GR-63-CORE Compliant
Environmental Compliance: RoHS
Package Quantity: 1 Cover
Carton Quantity: 5 Covers
Typical Use Case: Data Centers, Telecom Central Offices
Compatible Raceway: Panduit FiberRunner 12x4 Y-Reducer Base
Type: Fiber Management Cover
Durability: NEBS Level 3
Sub Brand: FiberRunner™
Color: Noir
Height In: 2.79
Height Mm: 70.9
Width In: 17.27
Width Mm: 438.6
Carton Qty: 5
Package Qty: 1
Standards: Conforme RoHS, assemblages de guidage de câble optique certifiés UL jusqu'à 2024A, conformes aux épreuves d'application des normes Telcordia GR-63-CORE et Network Equipment Building Systems niveau 3
Upc: 61305676846
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources