Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Hubbell DFPCSTSCS25SM ST-to-SC OS2 Singlemode Duplex Fiber Patch Cord

Overview

The Hubbell DFPCSTSCS25SM is a 25-meter OS2 singlemode duplex fiber optic patch cord terminated with ST connectors on one end and SC connectors on the other, in a plenum-rated jacket. This specific ST-to-SC configuration addresses the real-world reality of mixed-legacy infrastructure: older security and telecom equipment commonly uses ST bayonet connectors while modern switches and transceivers favor SC duplex ports. Rather than deploying a media converter or running a new pull, this cord bridges the two in a single factory-terminated run. At 25 meters, it covers most inter-closet hops and long-rack or cross-room runs without the signal degradation concerns associated with multimode at distance.

Key Features

  • OS2 Singlemode Fiber: OS2 glass supports transmission distances up to 10km at 10 Gbps — orders of magnitude beyond multimode. For a 25-meter intra-building run, this means zero concern about bandwidth-distance product limitations, and the cord is forward-compatible if the link is ever extended or upgraded to higher-speed optics.
  • Duplex Configuration: Two fibers in one jacket — one for transmit, one for receive — so a single cord completes a bidirectional link. No second cord to route, label, or manage. This keeps cable trays and patch panels cleaner, especially in high-density fiber patch panel deployments.
  • ST-to-SC Connector Pairing: ST is a bayonet-style connector common on older surveillance cameras, legacy NVRs, and telecom gear; SC is a push-pull connector standard on most current SFP transceivers and switches. This Hubbell fiber cord handles the translation without adapters, which introduce additional insertion loss at each mating interface.
  • Plenum Jacket Rating: A plenum-rated jacket is required by code (NEC Article 770) when routing cable through air-handling spaces — above drop ceilings, in raised floors, or inside HVAC ducts. Using a non-plenum cord in these spaces is a code violation and a fire hazard. The DFPCSTSCS25SM is safe for above-ceiling and plenum pathway installations without conduit.
  • 25-Meter Length: Long enough to cross a server room, connect between adjacent IDF closets, or reach from a wall plate to a distant rack — without the slack management headache of a longer cord. Size the run correctly up front rather than coiling excess in a patch panel.

Integration and Compatibility

Compatible with any ST-port device (legacy NVRs, media converters, surveillance cameras with fiber uplinks) patching to SC-port equipment (SFP transceivers, fiber-to-Ethernet switches, Gigabit media converters). OS2 singlemode glass is compatible with 1310nm and 1550nm singlemode transceivers across 1G, 10G, and higher speeds. Verify that both endpoints are singlemode — pairing OS2 glass with multimode transceivers will produce severely attenuated or non-functional links. Route in any plenum air-handling pathway per NEC 770 without conduit. For enterprise structured cabling projects requiring matched patch cord sets or custom lengths, verify the full Hubbell connectivity catalog for companion SKUs.

Frequently Asked Questions

Q: Can the DFPCSTSCS25SM be used in a non-plenum (riser or general) pathway?

A: Yes — a plenum-rated cord exceeds riser and general-use requirements, so it is safe to install in any pathway. Plenum is the highest fire-resistance jacket rating, so it satisfies riser (CMR) and general (CM) spaces as well.

Q: What equipment typically uses ST connectors that this cord would connect?

A: ST connectors appear on legacy surveillance cameras with fiber uplinks, older Ethernet media converters, some NVRs, and telecom patch panels deployed before SC became dominant. If your far-end device has a round bayonet-style fiber port, it is likely ST.

Q: Is OS2 singlemode compatible with multimode transceivers or OM3/OM4 fiber paths?

A: No. OS2 singlemode requires singlemode transceivers (typically 1310nm or 1550nm laser sources). Pairing OS2 glass with LED-based multimode transceivers will produce extremely high insertion loss and a non-functional link. Both ends of the path must be singlemode.

Q: Does duplex mean the DFPCSTSCS25SM carries both transmit and receive on a single cord?

A: Yes. Duplex means two fibers are jacketed together — one carries the transmit signal, the other the receive signal — completing a full bidirectional link in a single cable assembly.

Q: Is 25 meters long enough for a typical IDF-to-MDF closet run?

A: For intra-floor horizontal runs between adjacent closets, 25 meters (approximately 82 feet) covers most scenarios. For longer inter-floor or inter-building backbone runs, a longer cord or a spliced fiber infrastructure with patch cords at each end is the standard approach.

Ted Perry
Ted Perry

The DFPCSTSCS25SM addresses a specific and frequently underestimated pain point in security and telecom infrastructure: mixed-vintage connector populations. When you are connecting a legacy ST-port media converter or NVR to a current SC-port fiber switch, deploying this OS2 singlemode duplex cord at 25 meters eliminates the need for an ST-to-SC hybrid adapter — which adds one more mating interface and typically 0.2–0.5 dB of additional insertion loss per adapter pair.

Technical Highlights:

  • Plenum Jacket: NEC Article 770 mandates plenum-rated fiber in air-handling spaces — this cord meets that requirement without conduit, directly routing above drop ceilings or through HVAC-adjacent pathways in commercial buildings.
  • OS2 Singlemode Glass: Specified for 10km at 10G, so at 25 meters this cord contributes negligible attenuation. The OS2 designation also means it is forward-compatible with any future singlemode transceiver upgrade at either endpoint.
  • ST-to-SC Duplex Termination: Factory terminations on both ends mean insertion loss is controlled and repeatable. Field-terminated cords at this length are rarely justified; factory-polished ceramic ferrules on OS2 glass will outperform field epoxy terminations in most IDF environments.

Deployment Considerations:

  • Confirm both endpoints are singlemode before ordering — OS2 glass with multimode transceivers produces a non-functional link with no obvious visual indication of the mismatch at installation time.
  • At 25 meters, fiber bend radius management in a crowded patch panel still matters; OS2 singlemode glass has a tighter bend radius tolerance than multimode and kinking near the boot can permanently increase insertion loss.

This cord is the right specification for an IDF closet where a legacy ST-port surveillance appliance is being patched into a current SC-port Gigabit or 10G fiber switch — a common scenario in phased security system upgrades where not all equipment generations are replaced simultaneously.

Specifications
Overview: Fiber Patch Cords Plenum Duplex ST to SC Singlemode OS2 25 Meters
Connector: ST
Jacket Rating: PLENUM
Q&A
Reviews
Have Questions?

Hubbell Fiber Patch Cords Plenum Duplex ST to SC Singlemode OS2 25 Meters - DFPCSTSCS25SM

$216.00
$215.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources