Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Hubbell DFHPCCSCSS1SM OS2 Single-Mode Duplex CS-CS Fiber Optic Patch Cord

Overview

The Hubbell DFHPCCSCSS1SM is a 1-meter OS2 single-mode duplex fiber optic patch cord terminated with CS connectors on both ends and finished in a plenum-rated yellow jacket. OS2 single-mode fiber supports long-haul, low-attenuation transmission — suited for backbone runs between IDF/MDF closets or structured cabling links where distance and signal integrity matter more than short-reach multimode economics. The 1-meter length targets patch panel to active equipment connections in the same rack or adjacent enclosures, keeping slack minimal and airflow unobstructed. Explore the full Hubbell structured cabling line for compatible panels and connectivity hardware.

Key Features

  • OS2 Single-Mode Fiber: OS2 supports transmission distances well beyond multimode limits — typically up to 10km at 10G and beyond at lower data rates — making it the right choice for backbone interconnects rather than short horizontal runs. Yellow jacket follows the TIA-598 color standard for OS2, so field technicians immediately identify fiber type without reading labels.
  • CS-to-CS Connector Configuration: CS (Compact Single-fiber) connectors deliver a smaller footprint than LC connectors, enabling higher port density in patch panels and transceivers designed for the CS interface. Both ends are CS, so this cord connects two CS-port devices directly — verify your active equipment and patch panel both carry CS ports before ordering.
  • Duplex Construction: Two fibers in a single assembly handle simultaneous transmit and receive paths, which is the standard requirement for full-duplex transceiver links. No separate TX/RX cords to manage or cross-connect.
  • Plenum-Rated Jacket: The plenum rating (CMP) means this cord meets fire code for installation in air-handling spaces — drop ceilings, raised floors, and HVAC plenums — without requiring conduit. Buildings with open plenum airflow paths require CMP-rated cabling; using a non-plenum cord in those spaces violates NEC Article 770. If your run stays inside a conduit or equipment room, a riser-rated cord would suffice, but plenum works everywhere riser does.
  • 1-Meter Length: Sized for same-rack or adjacent-rack patching — long enough to route cleanly through a cable manager without excess coiling. For longer runs or cross-aisle links, select a longer variant in the same family.

Integration and Compatibility

The DFHPCCSCSS1SM is designed for structured cabling environments where CS-port transceivers or patch panels are already deployed. CS connectors are increasingly specified in high-density data center and enterprise MDF builds where LC's port density is no longer sufficient. Confirm transceiver compatibility — CS-interface SFP/SFP+ modules are required on both ends. This cord is not interchangeable with LC, SC, or MPO-terminated assemblies without an adapter. For fiber optic cable and assembly options across connector types and lengths, review the full catalog.

Frequently Asked Questions

Q: What does OS2 mean, and is this cord single-mode or multimode?

A: OS2 is a single-mode fiber standard (ITU-T G.652.D). Single-mode fiber uses a much smaller core (typically 9 microns) than multimode and supports longer transmission distances with lower attenuation. This cord is single-mode.

Q: What connector type does the DFHPCCSCSS1SM use?

A: Both ends use CS (Compact Single-fiber) connectors. CS connectors are smaller than LC connectors and are designed for high-density patching environments. Your patch panel ports and transceiver cages must be CS-compatible to use this cord.

Q: Can this cord be installed in a plenum ceiling space?

A: Yes. The plenum-rated (CMP) jacket meets NEC Article 770 requirements for installation in air-handling spaces including drop ceilings and raised floors used as HVAC plenums, without requiring conduit.

Q: Is this a simplex or duplex cord?

A: Duplex — two fibers bonded in a single assembly, providing simultaneous transmit and receive paths for full-duplex transceiver links.

Q: What is the length of the DFHPCCSCSS1SM?

A: 1 meter. This length is suited for same-rack or adjacent-rack patching. If you need a longer run, select a longer variant in the same cord family.

Marty Allison
Marty Allison

The DFHPCCSCSS1SM is a straightforward cord for a specific job: patching two CS-port devices over a 1-meter span in a single-mode OS2 backbone environment. The CS connector is the detail that matters most here — if your transceivers or high-density panels carry CS ports, this is the right assembly; if they carry LC or SC, it is not, and no adapter scenario is clean enough to recommend for a permanent install.

Technical Highlights:

  • OS2 Single-Mode Fiber: Supports transmission up to 10km at 10G (per ITU-T G.652.D) — backbone-grade fiber in a short patch assembly, which is correct when your entire structured cabling plant is single-mode and you need consistency at every connection point.
  • Plenum (CMP) Jacket: The CMP rating satisfies NEC Article 770 for open air-handling plenum spaces without conduit — useful in enterprise buildings where cable trays run through HVAC zones and riser-rated cable would require additional protection.
  • 1-Meter Duplex Assembly: The 1-meter duplex format handles both TX and RX in a single managed cord, reducing the chance of a crossed fiber pair during patching — a common commissioning error on high-density CS panels where individual fiber identification is harder than on LC.

Deployment Considerations:

  • CS connectors require CS-compatible port cages. Before specifying this cord, confirm the transceiver module part numbers on both endpoints explicitly list CS as the connector interface — SFP+ CS variants are a distinct SKU from LC variants at the transceiver level.
  • At 1 meter, this cord has essentially no slack for re-routing if rack positions shift. If there is any chance the active equipment moves to a non-adjacent slot, spec a 2-meter or 3-meter variant to avoid a recabling event.

This cord fits cleanly in a high-density single-mode MDF or IDF build where CS-interface patch panels terminate backbone fiber and CS-port transceivers connect to spine switching — specifically the short hop between panel port and switch faceplate where a 1-meter assembly is the tightest professional fit.

Specifications
Overview: Fiber Optic Patch Cord Plenum Rated MultiMode Duplex CS-CS OS2 1 Meter Yellow
Jacket Rating: PLENUM
Length: 1 METER
Connector Type: CS to CS
Fiber Type: OS2
Mode: singlemode
Color: Yellow
Construction Material: Plenum PVC
Application: High Density Fiber
Rated Value: Plenum Rated
Q&A
Reviews

Hubbell CS-CS 1 Meter - DFHPCCSCSS1SM

$93.00
$59.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources