Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL42UG2EZ-3048-W-MSS 42U Seismic-Rated Server Rack Enclosure

Overview

The Vertiv GL42UG2EZ-3048-W-MSS is a 42U floor-standing server rack enclosure built for environments where seismic certification isn't optional — data centers in earthquake-prone zones, government facilities with NEBS or GR-63 requirements, and any enterprise installation where a toppling rack is a catastrophic failure mode. At 30 inches wide and 48.4 inches deep, it fits standard raised-floor tile grids while accommodating full-depth servers, UPS units, and high-density patch infrastructure without internal conflicts. The white finish distinguishes it in lab or operations center environments where color-coding aids zone identification. If you're searching for this unit, it's also commonly referenced as GL42UG2EZ 3048 W MSS.

This enclosure is part of Vertiv's Vertiv infrastructure line, which covers power, cooling, and physical infrastructure for enterprise and edge deployments. For buyers evaluating the full physical layer stack, the server rack enclosure category includes the broader Vertiv EZ Seismic family alongside competitive alternatives.

Key Features

  • 3,000 lb Static Load Capacity: At 3,000 lbs static, this rack handles fully-populated blade chassis, dense storage arrays, and stacked UPS modules without deflection concerns. That's enough headroom for an 84-slot blade server fully loaded — you're not engineering around the rack's limits here.
  • 2,250 lb Dynamic (Seismic) Load Rating: The 2,250 lb dynamic rating means the structure is engineered to survive lateral seismic forces while loaded — not just to hold weight at rest. For facilities in seismic zones 2–4, this rating is a procurement checklist item, not a marketing differentiator. Verify against your local building code and AHJ requirements before spec-in.
  • 42U Height: 42U gives you the full standard rack height — enough for an entire compute stack (servers, top-of-rack switches, patch panels, PDUs) in a single enclosure. Mixed environments that need 45U or 48U should evaluate taller units in the EZ Seismic line before committing.
  • 30-Inch Width: The 30-inch width splits the difference between 19-inch (too narrow for cable-dense environments) and 24-inch wide-body frames. It accommodates standard 19-inch EIA-310 rail-mount equipment with room on both sides for vertical cable managers — a real benefit on installs where side-entry cables would otherwise crowd the front rail.
  • 48.4-Inch Depth: At 48.4 inches, this enclosure fits full-depth 1U and 2U servers (typically 25–30 inches) plus rear cable trays, rear PDUs, and airflow baffles without stacking them. Shallow 24-inch-depth enclosures force compromises on cable bend radius and airflow; this depth eliminates that.
  • Integrated Cable Routing: Built-in cable routing provisions reduce the time spent improvising cable management at installation — a factor in high-density deployments where pulling cables post-population means working around live equipment.
  • Floor-Standing Form Factor: Floor-standing deployment means no wall-load engineering, no ceiling clearance calculations, and no weight distribution concerns for overhead mounting. Place, level, anchor, and populate. For raised-floor environments, confirm floor tile load ratings against the populated weight before anchoring.
  • White Finish: White enclosures improve ambient light reflection in enclosed or poorly-lit server rooms and help distinguish lab or staging environments from production racks in facilities that use color zoning. If your facility standardizes on black enclosures, the same unit is available in black — verify the alternate MPN before ordering.

Integration and Compatibility

The GL42UG2EZ-3048-W-MSS accepts standard 19-inch EIA-310-compliant rack-mount equipment across all 42U positions. The 48.4-inch interior depth accommodates full-depth servers and storage arrays from major OEMs. Cable routing provisions are compatible with standard vertical and horizontal cable managers. For complete physical layer planning — including rack PDU selection and cable management accessories — verify that add-on components match the enclosure's rail spacing and interior dimensions before ordering.

Seismic anchoring hardware compatibility should be confirmed against your floor type (concrete slab vs. raised floor vs. wood subfloor) — the enclosure's seismic rating is only valid when properly anchored per Vertiv's installation specifications. Consult your facility's structural engineer for zone-specific anchoring requirements.

Frequently Asked Questions

Q: What is the static load capacity of the GL42UG2EZ-3048-W-MSS?

A: The GL42UG2EZ-3048-W-MSS is rated for 3,000 lbs static load capacity, making it suitable for fully-populated blade chassis, dense storage arrays, and stacked UPS configurations.

Q: What is the dynamic (seismic) load rating for this enclosure?

A: The dynamic load rating is 2,250 lbs. This means the enclosure is engineered to maintain structural integrity under lateral seismic forces while populated. Proper anchoring per Vertiv installation specs is required for the seismic rating to apply.

Q: What rack unit equipment fits inside this enclosure?

A: The GL42UG2EZ-3048-W-MSS provides 42U of usable rack space and accepts standard 19-inch EIA-310-compliant equipment. The 48.4-inch depth accommodates full-depth servers and storage arrays from major OEMs.

Q: Is the white finish the only color option available?

A: The GL42UG2EZ-3048-W-MSS ships in white. A black variant in the EZ Seismic family may be available under a separate MPN — verify with your distributor if black is required for your facility's standardization.

Q: Does the 30-inch width support standard cable managers and side accessories?

A: Yes. The 30-inch width accommodates standard 19-inch EIA-310 rail-mount equipment and leaves room on both sides for vertical cable managers, providing organized cable routing without crowding the front rails.

Q: What floor types are compatible with seismic anchoring for this unit?

A: The seismic rating applies when the enclosure is anchored per Vertiv's installation specifications. Floor type compatibility (concrete slab, raised floor, wood subfloor) should be verified with a structural engineer for your seismic zone requirements.

Eden Phillips
Eden Phillips

The spec that anchors my recommendation of the GL42UG2EZ-3048-W-MSS is the 2,250 lb dynamic load rating — that number represents real seismic engineering, not a static-load spec dressed up with a certification sticker. If you're deploying in California, the Pacific Northwest, or any Zone 3–4 seismic region, the gap between a seismic-rated enclosure and a standard rack under lateral load is the difference between a recoverable event and a total-loss data center floor.

Technical Highlights:

  • 3,000 lb Static / 2,250 lb Dynamic: The load spread between static and dynamic (a 25% reduction) reflects genuine engineering margin for seismic events — most non-rated racks publish only static figures, making direct comparison misleading. These numbers should appear in your facility's rack specifications sheet.
  • 42U x 30in x 48.4in Form Factor: The 48.4-inch depth is the practical enabler here — it lets you run full-depth 2U servers, rear PDUs, and structured cable trays simultaneously without compromising airflow baffling between the server exhaust and the rear door.
  • Integrated Cable Routing: Factory-built routing provisions avoid the post-hoc cable tray bolting that adds install time and introduces vibration points — a real concern in seismic environments where loose hardware is a failure mode.

Deployment Considerations:

  • The 2,250 lb dynamic rating is only valid when the enclosure is anchored per Vertiv's published seismic installation procedure — the rating does not apply to free-standing deployment. Confirm your floor type and anchor hardware before installation.
  • At 30 inches wide, this enclosure will not fit in a standard 24-inch-wide aisle configuration without aisle clearance planning — factor in door swing and cable tray protrusion on both sides when laying out your floor plan.

This enclosure is the right spec for a seismically-compliant co-location deployment or a government data center build-out where AHJ sign-off requires a documented dynamic load rating — it is not oversized for that purpose, and the white finish integrates cleanly in lab environments where rack identification by color zone is standard practice.

Specifications
Mount Type: Rack
Product Type: Server Rack Enclosure
Cable Category: Enterprise
Form Factor: Floor-standing
Color: White
Mounting: Floor-standing
Height: 42U
Width: 30 in
Depth: 48.4 in
freight: 798.42
Q&A
Reviews

Vertiv EZ Seismic 42U 30IN 48.4IN White - GL42UG2EZ-3048-W-MSS

$9,964.00
$7,026.99

RELATED PRODUCTS

Save $3,076.01
Image coming soon
Add to Cart The item has been added

Vertiv GL48UG2EZ-3048-W-MSS

Vertiv EZ Seismic 48U 30IN 48.4IN White - GL48UG2EZ-3048-W-MSS

48U seismic-rated enclosure designed for secure, organized deployment of IT and network equipment in environments subject to seismic activity

    Usually Ships in 2-3 Weeks Free shipping over $499
    $10,394.00 $7,317.99 Save $3,076.01
    The item has been added Add to quote
    $10,394.00 $7,317.99 Save $3,076.01
    Save $3,076.01 Add to cart Add to quote

    System Design, Deployment & Technical Support

    Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

    Fixed scope • Fixed price

    System Design Assistance

    • Get help validating product compatibility
    • Coverage requirements
    • Storage planning and deployment architecture before you buy.
    Request Design Help

    Deployment & Configuration Support

    • Access fixed-scope support for rollout planning
    • User setup guidance
    • Migration and system standardization across single-site or multi-site deployments
    View Support Services

    Guides, Tools & Calculators

    • PoE requirements
    • Storage retention
    • Camera selection and deployment methodology
    Open Technical Resources