Vertiv ES Door RND Mesh 98IN H X 30 in BLK - 9802E-MC29-B
Large-format enclosure designed to house and protect rack-mounted IT infrastructure, network equipment, and surveillance components
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv 7902E-MC29-B is a precision cooling system rated at 29 kW (91.4 kBtuh) net sensible capacity, built for data center rows, server rooms, and high-density IT environments where stable temperature and humidity control is non-negotiable. With R-410A refrigerant, variable-speed EC fans, and Liebert iCOM unit control, the 7902E-MC29-B is engineered for continuous-duty operation and energy-efficient modulation — not a one-speed-fits-all approach.
Precision cooling at this scale (29 kW sensible / 31 kW total) is a different discipline than comfort cooling. Data centers generate heat that HVAC systems aren't designed to handle at the density or duty cycle required. The 7902E-MC29-B addresses this with upflow and downflow airflow configurations, a 4,300 CFM fan array, and a controls platform — Liebert iCOM — that integrates with broader data center infrastructure management (DCIM) environments. At 79 inches tall and built to Vertiv's Liebert product line standards, this unit fits standard data center floor plans. For buyers evaluating precision cooling solutions or comparing within the Vertiv product catalog, the 7902E-MC29-B sits in the mid-to-large capacity tier of the Liebert ES series.
The Liebert iCOM control system on the 7902E-MC29-B supports integration with building management systems (BMS) and DCIM platforms via standard protocols. The unit is designed for use within Vertiv's broader precision cooling ecosystem, which includes complementary units, economizers, and monitoring software. When deploying multiple units in a data center row, iCOM's coordinated control capability allows units to share load and manage redundancy without manual intervention. For facilities already running Liebert precision cooling — see Liebert cooling units — the iCOM architecture is a direct fit into existing management workflows.
Q: What is the net sensible cooling capacity of the Vertiv 7902E-MC29-B?
A: The 7902E-MC29-B delivers 26.8 kW (91.4 kBtuh) net sensible capacity. Total capacity is 31 kW (105.9 kBtuh). For IT load planning, use the net sensible figure — it represents the actual heat removal available for IT equipment.
Q: Does the 7902E-MC29-B support both upflow and downflow airflow configurations?
A: Yes. The unit supports both upflow and downflow airflow directions, making it compatible with raised-floor environments as well as slab-floor data centers with overhead return plenums.
Q: What refrigerant does the 7902E-MC29-B use?
A: The 7902E-MC29-B uses R-410A refrigerant. Buyers planning long-term fleet deployments should verify current and upcoming R-410A regulatory timelines in their jurisdiction.
Q: What control system does the 7902E-MC29-B use?
A: It uses the Liebert iCOM Unit Control platform, which provides local and networked management, alarm handling, and multi-unit coordination. iCOM integrates with Vertiv Environet and supports BMS/DCIM connectivity.
Q: What is the airflow rating on the 7902E-MC29-B?
A: Nominal airflow is 4,300 CFM, delivered via variable-speed EC fans that modulate based on actual load — reducing energy use during partial-load operation.
Q: How does the 7902E-MC29-B fit into a standard data center floor plan?
A: The unit is 79 inches (approximately 1,970 mm) tall, aligning with standard rack heights. Confirm floor-to-ceiling clearance and hot/cold aisle containment geometry before finalizing placement.

The spec that drives most 7902E-MC29-B purchase decisions is the 26.8 kW net sensible figure — and buyers frequently conflate that with the 31 kW total capacity number. For IT thermal planning, only the sensible capacity matters: that's the actual joules-per-second you're pulling out of the airstream for your servers. The 7902E-MC29-B lands in the right range for a dense 10–15 rack row at moderate per-rack loads, or a smaller cluster running high-density compute.
Technical Highlights:
Deployment Considerations:
The 7902E-MC29-B is the right specification for a mid-density server room or co-location row where iCOM integration is already in use and the facility team needs a unit that can coordinate with neighbors — not just cool in isolation. Standalone single-row deployments in new slab-floor builds are where this unit's dual-direction airflow and EC modulation pay off most directly.