Vertiv ES Door Mesh Contour 91 X 24 in Black - 9102E-MC24-B
91-inch tall by 24-inch wide mesh door contour designed to enhance airflow and access for specific Vertiv enclosure systems
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv 9102E-MC29-B is a precision cooling unit from the Liebert ES series, engineered to deliver 29 kW (91.4 kBtuh) of net sensible cooling capacity in data center rows, server rooms, and high-density compute environments. At 4,300 CFM nominal airflow and support for both upflow and downflow configurations, this unit targets facilities where flexible deployment geometry matters as much as raw cooling output. The 9102E-MC29-B (often searched as 9102E MC29 B) ships in a black door mesh contour profile sized at 91 × 30 inches, designed for in-row or perimeter placement alongside standard 19-inch rack infrastructure.
For data center managers and infrastructure architects evaluating Vertiv precision cooling options, the ES series sits in the mid-range of Liebert's precision cooling lineup — high enough capacity to handle dense compute rows, with variable-speed fan control to avoid the energy penalty of full-speed operation in partially loaded rooms.
The 9102E-MC29-B integrates with Vertiv's Liebert iCOM controls ecosystem, which supports connection to building management systems (BMS) and DCIM platforms via standard protocols. Facilities teams managing mixed-vendor environments should confirm communication protocol support (BACnet, Modbus, SNMP) with their BMS vendor during pre-installation planning. For sites running data center infrastructure at scale, iCOM's fleet-management capability allows centralized monitoring across multiple precision cooling units without deploying separate local HMIs at each unit.
Pair this unit with appropriate UPS and power conditioning infrastructure to protect the cooling system itself from input power transients — precision cooling failures during a thermal event compound the risk profile of any IT load disruption. Consult your facilities engineer on data center power planning to correctly size branch circuits for the unit's input power requirements.
Q: What is the net sensible cooling capacity of the Vertiv 9102E-MC29-B?
A: The 9102E-MC29-B delivers 91.4 kBtuh (26.8 kW) net sensible cooling capacity, with a total nominal capacity of 98.9 kBtuh (29 kW) and total capacity of 105.9 kBtuh (31 kW).
Q: Does the 9102E-MC29-B support both upflow and downflow configurations?
A: Yes. The unit supports both upflow and downflow airflow directions, making it deployable in raised-floor (downflow) or slab-floor open-aisle (upflow) data center layouts without requiring a different model.
Q: What fan technology does the 9102E-MC29-B use, and why does it matter?
A: The unit uses variable-speed electronically commutated (EC) fans. EC fans modulate speed based on actual cooling demand, reducing energy consumption during partial-load conditions and extending motor service life compared to fixed-speed units — a meaningful factor in 24/7 data center operation.
Q: What refrigerant does the 9102E-MC29-B use?
A: The unit uses R-410A refrigerant. Buyers in jurisdictions with active R-410A phase-down schedules should factor refrigerant roadmap planning into procurement decisions.
Q: What controls platform does the 9102E-MC29-B ship with?
A: The unit ships with Liebert iCOM unit control, Vertiv's standard precision cooling controller, which supports local monitoring, setpoint management, and integration with BMS and DCIM platforms.
Q: What is the nominal airflow of the 9102E-MC29-B?
A: The unit delivers 4,300 CFM nominal airflow, sufficient to maintain disciplined cold aisle supply or return paths in mid-density rack row deployments.

The 9102E-MC29-B is the unit I'd recommend when a facility team needs to match a mid-density row deployment — roughly 25–30 kW of IT load — without over-specifying into a larger chassis that burns floor space and capital. The 91.4 kBtuh (26.8 kW) net sensible figure is what I focus on when sizing: total capacity numbers inflate the apparent output, but sensible is what your servers actually receive. At 4,300 CFM, it moves enough air to hold aisle temperature discipline in a properly sealed row without needing supplemental spot coolers.
Technical Highlights:
Deployment Considerations:
The 9102E-MC29-B is the right fit for a mid-density compute row in a colocation or enterprise data center where you need disciplined sensible cooling, flexible airflow direction, and a controls platform that plays well with existing DCIM infrastructure — not a general-purpose comfort-cooling workaround pressed into IT service.