Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL840ES-2448-B-MSS 44U Server Cabinet with Split Mesh Rear Door

Overview

The Vertiv GL840ES-2448-B-MSS is a 44U, 24-inch-wide by 48-inch-deep server enclosure finished in black, configured with a mesh contour front door and a split mesh rear door. The split rear door is the defining feature here — it opens from the center, allowing rear access in constrained aisles or wall-adjacent rows where a single swing door would be blocked. If your cabinet rows are dense or your hot-aisle/cold-aisle containment leaves little clearance behind each rack, this configuration earns its place. Browse the full Vertiv rack and enclosure catalog to compare the ES family across sizes and door configurations.

The GL840ES-2448-B-MSS (often searched as GL840ES 2448 B MSS) is part of Vertiv's Geist/ES cabinet line, targeting structured data center and IT closet deployments where a balance of airflow, cable access, and footprint control matters. The 24-inch width is narrower than the 30- and 32-inch variants in the same family, which makes it the right pick for patch-panel-heavy deployments or telecom-style closets where you're running 1U switching and 1U patch panels in alternating rows rather than wide 4-post server chassis.

Key Features

  • 44U Usable Height: 44U gives you enough vertical real estate for a fully populated switching, patching, and server stack without crossing into the 48U or 52U tiers that require ceiling clearance many IT closets can't provide. Plan on roughly 4–6U of buffer for cable management panels and blanks — effective usable density lands around 38–40U in a typical deployment.
  • 24-Inch Interior Width: The 24-inch form factor fits standard 19-inch rackmount equipment with standard rail sets, while keeping the external footprint tight. This is the width to specify when you're placing cabinets in a narrow server room, a wiring closet, or a row where every inch of aisle width counts. The 30- and 32-inch variants in the same family accommodate wider equipment or additional side cable troughs if your cabling volume demands it.
  • 48-Inch Depth: At 48 inches of usable depth, this cabinet accommodates mid-depth and full-depth 1U and 2U servers, storage arrays, and deep UPS units without compromising front-to-rear cable routing. Shallow-depth networking gear (patch panels, 1U switches) will have excess depth available, which becomes useful for rear cable management arms and vertical cable runs.
  • Mesh Contour Front Door: The mesh front door maintains front-to-rear airflow for equipment that relies on passive or forced-air front intake — which covers most 1U rack servers, managed switches, and network appliances. Solid or glass front doors restrict intake airflow and force internal fans to work harder; mesh avoids that problem without sacrificing door-latch security.
  • Split Mesh Rear Door: The split rear configuration opens in two half-width panels rather than one full swing. In a hot-aisle/cold-aisle layout where rear access is constrained by containment curtains or by adjacent rows, a single full-swing rear door may be physically blocked. The split design reduces the swing clearance requirement by roughly half, making rear-access maintenance practical in tight aisles. This is the primary reason to choose this SKU over the single-swing mesh rear variant.
  • Black Finish: The black powder-coat finish is the standard choice for mixed-vendor data center rows, colocation deployments, and enterprise IT spaces where visual uniformity matters. The Winter White color option exists in the same family for environments with specific aesthetic requirements — labs, healthcare equipment rooms, or integration with white-finished infrastructure.
  • ES Family Configurability: The ES line is available in multiple height, width, and depth combinations — 24U through 52U, 24 through 32 inches wide, 42 or 48 inches deep — so the GL840ES-2448-B-MSS can be paired with identically sized units in the same row, or scaled up to taller or wider variants as rack density grows. See server racks and enclosures to compare the full range of compatible enclosures.

Integration and Compatibility

The GL840ES-2448-B-MSS is designed around the standard 19-inch EIA rack rail pattern, compatible with virtually all commercial rack-mount equipment — switches, patch panels, 1U/2U servers, KVM drawers, UPS units, and cable management accessories. When pairing with rack PDUs, confirm vertical mount clearance against the 44U column height; a rear-mount vertical PDU will occupy side-channel space, not U-space, so it won't eat into your 44-unit count. For high-density patching environments, horizontal and vertical cable management panels from Vertiv's own accessory line are sized to fit this cabinet's 24-inch interior width — verify accessory rail compatibility before ordering third-party cable managers. Blanking panels for unused U-slots should be installed to maintain front-to-rear airflow discipline; perforated blanks are preferred over solid in high-airflow deployments. If you're populating this cabinet as part of a structured cabling build-out, pair it with patch panels and cable management accessories sized for 24-inch-wide mounting.

Frequently Asked Questions

Q: What is the door configuration on the GL840ES-2448-B-MSS?

A: The GL840ES-2448-B-MSS ships with a mesh contour front door and a split mesh rear door. The split rear opens in two half-panels from the center, reducing the swing clearance needed for rear access in tight aisles.

Q: Is the 24-inch width sufficient for standard 19-inch rack equipment?

A: Yes. The 24-inch interior width accommodates all standard 19-inch EIA rackmount equipment. The narrower footprint compared to 30- or 32-inch variants makes it well-suited for dense rows and space-constrained closets.

Q: What is the difference between the 42-inch and 48-inch depth options in the ES family?

A: The GL840ES-2448-B-MSS is the 48-inch-deep variant, which accommodates full-depth servers, storage arrays, and deep UPS chassis. The 42-inch depth is sufficient for most networking-only deployments. Choose 48 inches if your equipment lineup includes any full-depth 1U or 2U servers.

Q: Why would I choose this cabinet over a single-swing rear door variant?

A: If your rack rows have limited rear clearance — common in hot-aisle/cold-aisle containment setups or in rows placed close to walls — a single full-swing rear door may be physically blocked during maintenance. The split rear door on the GL840ES-2448-B-MSS requires roughly half the swing clearance, keeping rear access practical in constrained environments.

Q: Does the ES family support matching units in taller or wider sizes?

A: Yes. The ES line covers 24U through 52U heights, 24 through 32 inches of interior width, and 42- or 48-inch depths — all sharing the same family design and accessory ecosystem. You can populate a row with multiple GL840ES variants at different heights while maintaining a consistent external profile.

Q: Is the black finish standard, or is another color available?

A: Black is the standard finish for this SKU. A Winter White color option is available in the ES family for environments with specific aesthetic or facility requirements.

Eden Phillips
Eden Phillips

The detail that drives most purchasing decisions on the GL840ES-2448-B-MSS is the split mesh rear door — not the U-count or the color. In any containment row where rear clearance falls below 36 inches, a single-swing full-width rear door becomes a maintenance liability. I've seen 48-inch-deep cabinets in tight hot-aisle layouts where the rear door physically cannot open past 90 degrees without hitting the containment curtain frame. The split rear on this unit sidesteps that problem at the design level.

Technical Highlights:

  • 48-Inch Depth: Accommodates full-depth 2U servers and deep rack-mount UPS units without forcing front-only cable routing — a real advantage when you're mixing compute and infrastructure in the same column.
  • 24-Inch Interior Width: Keeps the external cabinet footprint narrow, which matters in closets and edge deployments where aisle width is non-negotiable. All standard 19-inch rail sets fit without modification.
  • Split Mesh Rear Door: Two independently swinging half-panels cut required rear swing clearance roughly in half compared to a single-panel design — the correct choice whenever containment geometry or wall proximity constrains rear access.

Deployment Considerations:

  • At 24 inches wide and 48 inches deep, this cabinet is depth-dominant — verify floor tile cutouts and cable entry points are positioned for a deep chassis before finalizing placement in a raised-floor environment.
  • The mesh door configuration presumes front-intake, rear-exhaust airflow convention; if any equipment in the column uses top exhaust or reverse airflow, add blanking panels above and below that unit to prevent hot-air recirculation into adjacent intake zones.

This cabinet is the right specification for edge data rooms and IT closets where a contained hot-aisle row must stay maintainable despite tight rear clearance — particularly in healthcare, retail back-office, and light industrial environments where the server room wasn't designed with rack service access as the first priority.

Specifications
Height: 24U42U44U48U52U
Width: 24"30"32"
Depth: 42"48"
Color: BlackWinter White
Doors: Mesh Contour Front/RearMesh Contour Front/Split Mesh RearClear
freight: 711.90
Q&A
Reviews
Have Questions?

Vertiv GL840ES-2448-B-MSS 44U Cabinet

$6,098.00
$4,125.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources