Altronix EFLOW4NXV PWR SPLY W/ACM8
Power supply and distribution unit designed to simplify the installation of integrated surveillance and access control systems
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Altronix EFLOW4NA8V is a 220VAC-input access power controller that combines an eight-output fused relay distribution board (ACM8) with a built-in power supply and battery charger — purpose-built for international and 220V-grid deployments where you need independently switched, supervised power for up to eight access control loads. If you're commissioning mag locks, electric strikes, or door holders in a facility running on 220VAC 50/60Hz mains, this unit eliminates the need for a separate step-down transformer by accepting line voltage directly at 2.1A input current and delivering clean 12VDC or 24VDC output at 4A continuous. Explore the full Altronix power and access control line for compatible expanders and enclosures.
Housed in the BC400 enclosure (12"W × 15.5"H × 4.5"D, 8.65 lbs), the EFLOW4NA8V ships as a ready-to-wire assembly. The ACM8 controller board and eFlow power supply board are factory-installed together, with the option to wire a single common power input for both boards or to use two isolated inputs — useful when your access control panel demands electrically isolated lock power. All outputs are power-limited and individually fuse-protected, so a shorted strike or lock doesn't cascade and kill other doors.
The EFLOW4NA8V is designed to pair with virtually any access control system that provides open-collector or normally open dry-contact triggers — including common panels from Lenel, Software House, Mercury, HID, and others. The eight trigger inputs accept either open-collector or NO signals in any combination, so mixed-topology installations (some readers with open-collector outputs, some with relay outputs) wire directly without adapters. For larger installations requiring more than eight doors on a single power source, the ACM8 architecture is expandable via additional Altronix access power controllers on isolated inputs. Pair this unit with compatible access control hardware and consider a supplemental power supply if your load budget requires the two-isolated-input configuration for separated lock and controller power. Review your power planning approach before specifying battery backup capacity — the 1.54A charge current dictates minimum recovery time for your chosen battery.
Q: Is the EFLOW4NA8V NDAA Section 889 compliant?
A: Yes. The EFLOW4NA8V carries NDAA, TAA, and BAA agency listings, making it suitable for federal, defense, and government procurement projects that require domestic-sourcing and telecommunications equipment restrictions compliance.
Q: What input voltage does the EFLOW4NA8V require?
A: The EFLOW4NA8V accepts 220VAC 50/60Hz at 2.1A. It is not a dual-voltage unit — if your facility runs on 120VAC, you need a different model in the Altronix eFlow family designed for 115VAC input.
Q: Can the EFLOW4NA8V outputs be mixed between Fail-Safe and Fail-Secure modes?
A: Yes. Each of the eight outputs is individually configurable as Fail-Safe, Fail-Secure, or form C dry relay contact. You can run different modes on different outputs simultaneously on the same unit.
Q: How does the fire alarm disconnect work on the EFLOW4NA8V?
A: The FACP interface accepts normally open, normally closed dry contact, or polarity reversal input from a fire alarm control panel signaling circuit. The disconnect is individually selectable per output — latching or non-latching — so you can release only specific doors on alarm rather than all eight. An alarm output relay (form C, 1A / 28VDC) reports FACP input status back to your monitoring system.
Q: What battery types does the built-in charger support?
A: The onboard charger supports sealed lead acid and gel-type batteries at a maximum charge current of 1.54A. It includes automatic switchover on AC fail and a low-power shutdown that prevents deep discharge by cutting DC outputs when battery voltage drops below approximately 71–75% of nominal (range depends on 12V vs. 24V configuration).
Q: What are the enclosure dimensions and weight of the EFLOW4NA8V?
A: The BC400 enclosure measures 12"W × 15.5"H × 4.5"D and weighs 8.65 lbs (product weight). Shipping weight is 9.95 lbs.

The EFLOW4NA8V is one of the cleaner solutions I've specified for international access control projects running on 220VAC infrastructure. The direct 220VAC input at 2.1A eliminates the transformer stage that most 115V-native controllers require when deployed overseas or in facilities with 220V distribution — one less component to fail, one less enclosure to find wall space for. With eight independently triggered outputs at a combined 4A, it handles a typical multi-door wing without a secondary expander.
Technical Highlights:
Deployment Considerations:
This unit is the right specification for embassies, international manufacturing facilities, or any 220V-grid campus where you need per-door Fail-Safe/Fail-Secure flexibility, FACP integration, and NDAA/TAA compliance in a single factory-assembled enclosure — without the overhead of a separate transformer or standalone charger.
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Looking for more Altronix products? Shop the full Altronix catalog →
Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.