Vertiv E CAB Solid Door 72 in H X 29 in W - 7203E-29-X
72-inch high by 29-inch wide solid door cabinet designed to house and secure IT and network infrastructure
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Vertiv 7203E-29-B is a precision cooling unit engineered for data center and server room environments where thermal management must stay ahead of high-density compute loads. Rated at 98.9 kBtuh (29 kW) total nominal sensible capacity and measuring 72 inches tall by 29 inches wide in a black cabinet form, the 7203E-29-B is sized to fit standard aisle containment layouts without sacrificing cooling headroom. If your rows are running dense blade chassis or converged infrastructure, this unit is built for exactly that thermal profile — not the occasional hotspot, but sustained, continuous heat extraction at data center scale.
Part of the Vertiv precision cooling line, the 7203E-29-B operates with R-410A refrigerant and supports both upflow and downflow air delivery, giving you flexibility to match existing raised-floor or overhead-distribution architectures without a mechanical redesign. Explore the broader Vertiv cooling and power catalog for companion units and infrastructure components.
The Liebert iCOM control system is designed to interface with standard BACnet and SNMP-based data center cooling management platforms, making integration into existing DCIM or BMS environments straightforward. The iCOM controller supports remote monitoring, alarm notification, and performance trending — capabilities that matter for facilities teams managing multiple cooling units across a data center floor. If you are building out a full infrastructure stack, pair this unit with compatible power distribution and UPS solutions to ensure thermal and power management are coordinated.
For environments with strict floor space constraints, the 29-inch width is a key differentiator — it allows installation in narrower equipment rooms and edge deployments where a standard 36-inch-wide unit would not fit without a major layout revision. Review our data center infrastructure guide for aisle containment planning considerations before finalizing unit placement.
Q: What is the sensible cooling capacity of the Vertiv 7203E-29-B?
A: The 7203E-29-B delivers 91.4 kBtuh (26.8 kW) net sensible capacity, with a total nominal sensible capacity of 98.9 kBtuh (29 kW) and a total capacity of 105.9 kBtuh (31 kW).
Q: Does the 7203E-29-B support both upflow and downflow air delivery?
A: Yes. The unit supports both upflow and downflow airflow configurations, allowing it to integrate with raised-floor plenum systems or overhead air distribution layouts without mechanical modification.
Q: What refrigerant does the 7203E-29-B use?
A: The 7203E-29-B uses R-410A refrigerant for heat rejection. R-410A is widely available and supported by standard HVAC service infrastructure.
Q: What controller does the 7203E-29-B ship with?
A: The unit ships with the Liebert iCOM unit control system, which provides local monitoring, setpoint management, alarm handling, and integration capability with BMS and DCIM platforms.
Q: How does the 7203E-29-B modulate capacity?
A: Capacity modulation is achieved through variable speed electronically commutated (EC) fans, which adjust airflow output based on actual thermal load rather than running at a fixed speed. This improves energy efficiency during partial-load conditions.
Q: What are the physical dimensions of the 7203E-29-B?
A: The unit is 72 inches tall by 29 inches wide. The black cabinet finish is designed to integrate with standard rack row deployments.

When I look at the 7203E-29-B, the spec that stands out immediately is the 4,300 CFM airflow paired with variable-speed EC fans — that combination is what separates a unit that handles sustained high-density load from one that struggles at peak. At 29 kW nominal sensible and 91.4 kBtuh net sensible, this unit is sized for serious compute rows, not light-duty server closets.
Technical Highlights:
Deployment Considerations:
The 7203E-29-B is the right unit for a mid-density data center row or an edge compute installation where floor space is constrained to 29 inches of width but thermal load still hits the 25–29 kW range — environments where a larger-footprint unit simply won't fit and an undersized unit would throttle under load.