Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL840E-2936-W-1032MS 44U White Mesh Server Rack Enclosure

Overview

The Vertiv GL840E-2936-W-1032MS is a 44U steel rack enclosure designed for structured IT and network equipment deployments where airflow management and flexible mounting are primary requirements. Built in Winter White with a 29-inch wide by 36-inch deep footprint, this enclosure fits comfortably in data centers, server rooms, and network operations environments where equipment density and cable management must coexist. The GL840E-2936-W-1032MS (often searched as GL840E 2936 W 1032MS) ships as part of Vertiv's GL840E rack family, which offers several height, width, depth, and door configuration options to match specific deployment constraints.

Key Features

  • 44U Usable Height: 44U of rack space gives you room to consolidate servers, patch panels, switches, and PDUs in a single enclosure — reducing floor footprint compared to spreading equipment across multiple smaller racks.
  • 29-Inch Width: The 29-inch external width fits a standard 19-inch EIA mounting rail configuration while providing extra internal clearance for cable management on both sides, which matters when you're running dense structured cabling or power distribution across the full height.
  • 36-Inch Depth: At 36 inches deep, this enclosure handles full-depth servers (up to approximately 30–31 inches of usable internal depth) without forcing compromises — front-to-rear cable routing remains accessible with the doors closed.
  • Mesh Front and Rear Doors: The mesh door configuration on both the front and rear maximizes passive airflow through the enclosure. In environments without precision cooling (or where hot-aisle/cold-aisle containment handles the bulk of thermal management), mesh doors reduce the risk of heat buildup across high-density compute rows.
  • Winter White Finish: The Winter White color is a practical differentiator in certain environments — medical facilities, clean rooms, broadcast operations, and lab settings where white racks are specified for aesthetic or facility standards compliance.
  • Multiple Mounting Standards — #10-32, 3/8-inch Sq. (M6), and Clear Options: Support for #10-32, 3/8-inch square (M6), and clear mounting options means this rack is compatible with virtually all standard rackmount hardware from network, compute, and AV equipment vendors — no cage nut adapter kits required for common deployments.
  • GL840E Family Configurability: The GL840E series spans multiple heights (13U, 24U, 31U, 37U, 44U), widths (24-inch and 29-inch), and depths (32-inch and 36-inch), plus door variants (Mesh Front/Rear, Plexi Front/Solid Rear). This means you can standardize on the same enclosure family across different rooms or equipment types without sourcing from multiple vendors.

Integration and Compatibility

The GL840E-2936-W-1032MS is compatible with standard 19-inch rackmount equipment across the full 44U height. The #10-32, M6, and square-hole mounting options cover virtually all server, network, and AV equipment rails. For deployments where cable organization is critical, Vertiv's own PDU and cable management accessories designed for the GL840E series mount natively without modification. Explore the Vertiv rack and power product line for compatible PDUs, blanking panels, and cable management solutions. If you're building out a multi-rack row, consider pairing this enclosure with a rack-mount PDU sized for your load requirements. For structured cabling installations, see the structured cabling category for patch panels and cable management options that integrate cleanly with this rack's internal dimensions. Buyers planning high-density compute rows should also review network switches rated for rack deployment alongside this enclosure.

Frequently Asked Questions

Q: What door configuration does the GL840E-2936-W-1032MS include?

A: This model comes with mesh front and mesh rear doors, which maximize passive airflow through the enclosure. Plexi front / solid rear configurations are available in other GL840E variants.

Q: What mounting hardware standards does this rack support?

A: The GL840E-2936-W-1032MS supports #10-32, 3/8-inch square (M6), and clear mounting options, covering virtually all standard rackmount server, network, and AV equipment.

Q: Is the 29-inch width compatible with standard 19-inch rackmount equipment?

A: Yes. The 29-inch external width houses standard 19-inch EIA mounting rails. The additional width provides clearance for side-mounted cable management without impacting equipment compatibility.

Q: Can this rack be used in a hot-aisle/cold-aisle containment setup?

A: The mesh front and rear doors on this model are well-suited for hot-aisle/cold-aisle containment rows, as they do not obstruct airflow between the enclosure and containment baffles.

Q: Are other heights available in the GL840E family?

A: Yes. The GL840E series is available in 13U, 24U, 31U, 37U, and 44U heights, allowing you to standardize on the same enclosure family across installations with different height requirements.

Jerry Tildsen
Jerry Tildsen

The GL840E-2936-W-1032MS is the 44U, 29x36-inch, Winter White mesh variant of Vertiv's GL840E series — a rack I'd specify when the deployment environment calls for a non-standard color (medical, lab, broadcast) and the equipment load demands full-depth server clearance with unrestricted front-to-rear airflow.

Technical Highlights:

  • 36-Inch Depth: Provides roughly 30–31 inches of usable internal depth — enough clearance for full-depth 2U and 4U servers without rear cable conflicts when doors are closed.
  • Mesh Front and Rear Doors: Both door positions are mesh, which is the correct call for any row where you're relying on in-row or overhead cooling rather than door-level baffling. Solid rear doors trap heat; this configuration doesn't.
  • Multi-Standard Mounting (#10-32 / M6 / Clear): Supporting all three common rail standards in a single enclosure eliminates the adapter kit procurement step — relevant when you're mixing server vendors in a single rack build-out.

Deployment Considerations:

  • The 29-inch external width requires confirming aisle width and raised-floor tile alignment before delivery — this is wider than a standard 24-inch rack and affects row spacing in tight data center floors.
  • Winter White finish is a facility-spec color, not a standard stocking item at all distributors — confirm lead time before committing it to a project schedule with a hard cutover date.

Best positioned for medical imaging suites, broadcast control rooms, or clean-room IT closets where white enclosure specifications are facility-mandated and full-depth server density is required alongside unobstructed airflow.

Specifications
Mount Type: Rack
Height: 44U37U31U24U13U
Width: 24"29"
Depth: 32"36"
Color: BlackWinter White
Mounting: #10-323/8" sq. (M6)Clear
Doors: Mesh Front/RearPlexi Front/PV Solid Rear
freight: 645.34
Q&A
Reviews

Vertiv GL840E-2936-W-1032MS

$5,529.00
$3,931.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources