Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Vertiv GL840E-2932-B-1032P 44U Server Rack Enclosure with Plexi Front Door

Overview

The Vertiv GL840E-2932-B-1032P is a 44U open-frame rack enclosure built for data centers, server rooms, and structured wiring deployments where you need a commercial-grade cabinet with configurable door and depth options. At 29 inches wide and 32 inches deep, it provides the internal clearance required to house high-density server and network equipment without crowding cable runs or airflow paths. This is part of the Vertiv rack lineup — a family that spans multiple height, width, and depth combinations to match a wide range of floor-plan and load requirements.

The 44U height is the right pick when you are consolidating a rack room or building out a new row — 44U gives you meaningful headroom above a typical 42U baseline without stepping up to a physically taller footprint that complicates cable management overhead. If your equipment list is already close to 40U of gear, plan for blanking panels in the empty slots to maintain proper airflow front-to-back.

Key Features

  • 44U Usable Height: 44U of rack space accommodates more equipment per enclosure than the industry-standard 42U baseline — useful when consolidating two partially-filled racks into one, reducing floor footprint and associated cooling zones.
  • 29-Inch Width: The 29-inch frame (wider than the 24-inch variant in the same family) provides additional side clearance for high-density cable bundles, wide-body UPS units, or oversized 1U/2U servers that benefit from breathing room beside adjacent gear.
  • 32-Inch Depth: At 32 inches deep, this enclosure fits standard 1U through 4U servers and most mid-depth network switches. If you are housing deep-body enterprise servers (often 28-32 inches of chassis depth), verify your specific chassis length against this 32-inch interior measurement before ordering.
  • Plexi Front Door / Solid Rear: The plexi (clear acrylic) front door lets you visually confirm indicator lights and port status without opening the cabinet — practical in colocation and monitoring environments where physical access is restricted or logged. The solid rear panel contains rear-facing airflow and reduces ambient noise bleed into the room.
  • Black Finish: The black color option blends into standard raised-floor data center aesthetics and does not show fingerprints or dust as readily as white-finish alternatives. The Winter White variant is available in the same family if your environment requires it for visual differentiation.
  • #10-32 and 3/8-inch Square (M6) Mounting: Dual mounting hole standards — #10-32 threaded and 3/8-inch square (M6) — mean you can install equipment that ships with either cage nut style without sourcing adapter hardware. The clear mounting pattern makes rail alignment straightforward during dense buildouts.
  • Multiple Height and Depth Configurations in Family: The GL840E series spans 13U, 24U, 31U, 37U, and 44U heights, and 32-inch or 36-inch depths — so if your load grows or your floor plan changes, you can standardize on the same enclosure family across the room rather than mixing incompatible rail systems.

Integration and Compatibility

The GL840E-2932-B-1032P accepts standard EIA-310 rack equipment. The #10-32 and M6 square-hole mounting standards cover the vast majority of enterprise server, switch, patch panel, and UPS vendors. Pair this enclosure with rack PDUs and structured cabling infrastructure from the same Vertiv ecosystem for consistent mounting and cable management. For thermal management, verify your equipment's CFM requirements against the cabinet depth and door perforation — the solid rear door and plexi front combination is better suited for front-to-back airflow architectures with dedicated in-row cooling than for hot-aisle/cold-aisle open setups.

Browse the full Vertiv rack enclosure catalog to compare height and depth variants, or explore network cabinets and racks across vendors if you are evaluating alternatives.

Frequently Asked Questions

Q: What mounting hole standards does the GL840E-2932-B-1032P support?

A: It supports #10-32 threaded and 3/8-inch square (M6) cage nut mounting — the two most common standards for enterprise rack equipment, so you can install gear from most server and network vendors without adapter hardware.

Q: Is the 32-inch depth sufficient for full-depth enterprise servers?

A: Many enterprise servers measure 28-32 inches of chassis depth. Verify your specific server chassis length before ordering — the 32-inch interior depth is on the boundary for some deep-body 2U/4U servers when cable bend radius is factored in. The 36-inch depth variant in the GL840E family may be a safer fit for those applications.

Q: What is the difference between the plexi front door and the mesh front/rear door option?

A: The plexi (clear acrylic) front door on this model allows visual inspection of equipment status lights without opening the cabinet. Mesh door variants offer greater passive airflow at the cost of visual containment. Choose plexi when visibility and dust containment matter more than maximizing passive cooling area.

Q: What other heights are available in the GL840E family?

A: The GL840E series is available in 13U, 24U, 31U, 37U, and 44U heights — and in both 32-inch and 36-inch depth configurations — so you can standardize on a single enclosure family across a mixed-height deployment.

Q: Can the GL840E-2932-B-1032P be used in a security surveillance equipment room?

A: Yes. The 44U capacity and standard EIA rail mounting make it suitable for housing NVRs, video management servers, PoE switches, and patch panels common in enterprise surveillance infrastructure. Ensure adequate power distribution and thermal management are planned for the equipment being installed.

Eden Phillips
Eden Phillips

The GL840E-2932-B-1032P is a 44U, 29-inch-wide enclosure — and that extra 5 inches of width over the 24-inch variant is the detail that matters most in dense buildouts. When you are terminating structured cabling alongside 1U servers, the wider frame gives your vertical cable managers room to breathe without forcing 90-degree bends that crack jacket insulation over time.

Technical Highlights:

  • Dual mounting standards (#10-32 and M6): Supporting both threading types in the same rail eliminates the most common rack-build delay — hunting for the right cage nut kit on a build day. Every major server and switch vendor ships with one or the other, and this cabinet handles both without adapters.
  • Plexi front / solid rear door combination: Plexi front lets operations staff confirm link lights and drive activity through the door glass without logging a physical access event — relevant in audited colocation environments. The solid rear limits rear-facing light and noise bleed, which matters in mixed-use machine rooms.
  • 44U height in a 32-inch depth footprint: You get 44U of usable rail space without the footprint penalty of a 36-inch-deep cabinet — useful when floor tiles are metered and every 4 inches of row depth costs cooling capacity.

Deployment Considerations:

  • At 32 inches of interior depth, measure your deepest chassis before committing — some 4U storage servers and certain UPS models exceed 30 inches of chassis depth, and you will need the 36-inch variant in the GL840E family once cable bend radius is added to the chassis length.
  • The plexi front door is not perforated — passive front-to-back airflow is restricted compared to a mesh door. If your equipment load runs high TDP gear without blanking panels, plan for active cooling or verify that your in-row cooler or CRAC unit can compensate before the build is complete.

This enclosure is the right fit for a surveillance or IT consolidation room where you need 44U capacity, standard dual-hole mounting, and a plexi door for non-contact status checks — specifically in environments where physical access is logged or restricted and where 32-inch depth covers your full equipment list.

Specifications
Mount Type: Rack
Height: 44U37U31U24U13U
Width: 24"29"
Depth: 32"36"
Color: BlackWinter White
Mounting: #10-323/8" sq. (M6)Clear
Doors: Mesh Front/RearPlexi Front/PV Solid Rear
freight: 627.86
Q&A
Reviews

Vertiv E 44U 29IN 32IN - GL840E-2932-B-1032P

$4,762.00
$3,402.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources