Product images are provided for reference and may not represent the exact model, configuration, or included components.

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit D2ERTB 12-24 Tapped Equipment Rails for 42U Net-Verse D-Type Cabinets

The Panduit D2ERTB delivers 42 RU of 12-24 tapped mounting positions purpose-built for Panduit Net-Verse D-Type cabinets in 600 mm and 800 mm configurations. Sold as a matched pair, these rails drop into the D-Type frame without adaptation — giving you a clean, repeatable installation baseline whether you're racking security appliances, NVRs, or network gear in a structured physical security infrastructure build.

Overview

When you're populating a cabinet or rack enclosure with equipment that needs a reliable, thread-consistent mounting surface, the rail material and thread pattern matter more than buyers often anticipate. The D2ERTB uses a 12-24 tapped thread pattern — the standard machine screw thread used across the majority of rack-mount security and network hardware. That means no cage nuts, no thread inserts, and no field improvisation: the screw goes straight into the rail. Over 42 rack units, that translates to 168 mounting points per rail (four per U), all pre-tapped at the factory to consistent depth and thread engagement.

The rails measure 76 inches tall overall — spanning the full interior height of a 42U D-Type cabinet — and 2.6 inches wide (66 mm). At that profile, they sit inside the vertical frame channels of the Panduit Net-Verse cabinet family without protruding into the usable interior depth. The black finish matches the D-Type cabinet's interior aesthetic and resists surface corrosion in controlled indoor environments.

Key Features

  • 12-24 Tapped Thread Pattern: Machine-threaded mounting holes accept standard 12-24 rack screws directly — no cage nuts required. That removes a consumable from your install kit and eliminates the risk of a cage nut backing out under vibration over time. Every mounting point is mechanically identical across all 42U.
  • 42 RU Capacity: Full-height coverage for a standard 42U D-Type cabinet means you can configure the entire usable rack space from day one, or leave positions open for future expansion without needing a rail splice or extension. 168 total tapped positions per rail, 336 per pair.
  • Designed for Net-Verse D-Type Cabinets (600 mm and 800 mm): Dimensioned to fit Panduit's D-Type frame channels specifically — not a universal rail with adapter kits. That fit matters for alignment: rail-to-frame tolerances that are off by even 1–2 mm will cause rack-unit markings to drift and create binding on sliding equipment like keyboard/video/mouse trays or rack-mount UPS units.
  • Sold as a Pair: One D2ERTB order provides both a left and right rail — the minimum set needed to mount a single piece of rack equipment. No need to track a separate part number for the mate.
  • 76-Inch Overall Height (1930 mm equivalent): The rail length aligns with standard 42U EIA-310 rack geometry. If you're mounting precision-depth equipment like patch panels or dense fiber enclosures, consistent rail height ensures the U-markings on both sides stay in sync.
  • RoHS Compliant: Meets Restriction of Hazardous Substances requirements — relevant for enterprise and government deployments where material compliance documentation is part of the procurement checklist or facility certification. Keeps your bill of materials clean for LEED or similar facility audits.
  • Black Finish: Matches the interior finish of the Net-Verse D-Type cabinet line, maintaining visual consistency inside the enclosure. More practically, a dark rail color reduces reflective glare when working inside a lit cabinet — a minor but real factor during cable management and equipment swap sessions.

Integration & Compatibility

The D2ERTB is engineered specifically for Panduit Net-Verse D-Type cabinets in 600 mm and 800 mm widths. If you are working with a different Panduit cabinet series (N-Type, W-Type, or the XG line), verify the frame channel geometry before ordering — D-Type frame slots are specific to that product family and the rail shoulder profile is not interchangeable across all Net-Verse variants.

The 12-24 thread is compatible with the overwhelming majority of rack-mount hardware from security NVR manufacturers, network switch vendors, and structured cabling panel suppliers. Notable exception: some server and storage hardware ships with M6 metric threads or 10-32 threads — confirm your heaviest or most precision-fit equipment's screw spec before committing to a 12-24 rail. If your build mixes thread standards, a secondary cage-nut strip can be added to one rail pair, but that adds depth inside the cabinet.

These rails do not include mounting hardware for the cabinet frame — fasteners for rail attachment to the frame are typically provided with the cabinet or sourced separately as part of the Net-Verse accessory kit.

What's in the Box

  • 2x 12-24 Tapped Equipment Rails (left and right pair), 42 RU, black

Frequently Asked Questions

Q: What cabinet models is the D2ERTB compatible with?

A: The D2ERTB is designed for Panduit Net-Verse D-Type cabinets in 600 mm and 800 mm configurations. Compatibility with other Panduit cabinet series (N-Type, W-Type, XG) is not confirmed by the manufacturer for this rail — verify frame channel geometry before ordering for non-D-Type enclosures.

Q: Does the D2ERTB require cage nuts?

A: No. The D2ERTB uses a 12-24 tapped thread pattern, meaning standard 12-24 rack screws thread directly into the rail. Cage nuts are not required and are not included.

Q: How many rack units does the D2ERTB support?

A: The D2ERTB provides 42 RU of mounting positions per rail. The overall height is 76 inches, covering the full interior height of a standard 42U D-Type cabinet.

Q: Is the D2ERTB sold as a single rail or a pair?

A: It is sold as a pair — one order includes both the left and right rail needed to mount equipment in a single rack position column.

Q: Is the D2ERTB RoHS compliant?

A: Yes. The D2ERTB meets RoHS (Restriction of Hazardous Substances) compliance standards as confirmed by Panduit's product documentation.

Q: What screw size does the 12-24 tapped thread accept?

A: The 12-24 designation refers to a #12 diameter, 24 threads-per-inch machine screw — the most common rack mounting screw standard in North American IT and security infrastructure. Standard 12-24 rack screws (typically M6-equivalent in function, but not metric) are used with these rails.

Eden Phillips
Eden Phillips

The D2ERTB is one of those components that looks unremarkable on a spec sheet — a pair of black rails, 76 inches tall, 12-24 tapped — until you're 30 units into populating a cabinet and realize that thread consistency and rail-to-frame fit are the difference between a clean build and one that requires shimming, re-drilling, or swapping out panels mid-project. The 42 RU tapped design means every mounting point across the full cabinet height is mechanically identical, and the D-Type-specific shoulder profile means these rails won't shift laterally once seated.

Technical Highlights:

  • 12-24 Tapped at 42U: 168 pre-threaded positions per rail — 336 per pair — eliminates cage nut handling across the full cabinet. On a multi-cabinet row build, that's hundreds of cage nuts removed from the install workflow.
  • 76-inch overall height: Exact match to the D-Type cabinet interior span ensures U-markings on left and right rails stay in sync. Mismatched rail heights cause alignment drift that compounds when racking sliding trays or dense patch panels.
  • RoHS compliance documented: Clean materials declaration for procurement teams running LEED-certified data center or government facility builds where hazardous materials documentation is a hard requirement, not a checkbox.

Deployment Considerations:

  • These rails are specific to the Net-Verse D-Type frame channel geometry — 600 mm and 800 mm cabinet widths. Do not assume cross-compatibility with other Panduit Net-Verse series without confirming frame slot dimensions; a misfit rail in a full cabinet is a costly teardown.
  • Rail attachment fasteners to the cabinet frame are not included in the D2ERTB package — factor in hardware procurement separately, or confirm the D-Type cabinet kit includes them. Missing this on a large order adds lead time if you're sourcing last-minute.

Best fit for enterprise physical security or data center integrators standardizing on the Panduit Net-Verse D-Type platform who need a reliable, thread-consistent mounting foundation across a multi-cabinet deployment — particularly where mixed rack-mount security appliances and network hardware share cabinet space and cage-nut-free installation is a priority.

Specifications
Sub Brand: Net-Verse™
Height In: 76
Height Mm: 1.9
Width In: 2.6
Width Mm: 66
Product Type: Equipment Rail
Carton Qty: 0
Package Qty: 1
Standards: RoHS Compliant
Upc: 61305636269
Cable Category: cabinets-thermal-management-racks-enclosures
Q&A
Reviews
Have Questions?

Panduit D-type 12-24 Tappe E-rails 600/800 MM EA

$419.06
$251.99

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources