APC by Schneider Electric CONDENSER 127KW 95F/120F - ACCD76069
Condenser unit designed for specific environmental control applications, operating at 127KW with a 95°F/120°F temperature range
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The ACCD76057 is APC by Schneider Electric's 101kW airflow system condenser designed for high-density data center and enterprise infrastructure environments where heat rejection capacity and ambient temperature tolerance are non-negotiable. Rated to operate at ambient conditions up to 120°F (49°C), this unit is built for hot outdoor equipment rooms, rooftop mechanical enclosures, and industrial facilities where standard condensers fail under summer peak loads. At 101kW of cooling capacity, it pairs with APC's in-row and containment cooling systems to handle the thermal output of densely populated server aisles or power-intensive UPS and battery environments. If you're sizing cooling infrastructure for a greenfield data center build or expanding capacity on an existing hot aisle/cold aisle layout, the ACCD76057 belongs on your short list of data center cooling equipment.
The ACCD76057 is engineered as a condenser component within APC's modular cooling infrastructure. It pairs with APC in-row cooling units that require an external condenser for heat rejection — the condenser handles the refrigerant-side heat exchange, while the indoor unit manages airflow directly at the rack level. This split architecture keeps the noise and heat-rejection hardware outside the data hall, which matters in colocation environments and facilities with strict acoustic requirements.
Three-phase 208-230V power infrastructure is required. Coordinate with your facilities team on dedicated circuit sizing, disconnect requirements, and conduit routing before scheduling delivery. Given the 272.7 kg (601 lb) packaged weight, verify freight elevator capacity and floor load ratings on the delivery path — this is not a unit that gets hand-trucked into a basement MER without a plan.
For organizations managing mixed cooling deployments, the ACCD76057 fits within Schneider Electric's EcoStruxure architecture, which enables centralized monitoring and thermal management across multiple cooling zones from a single management platform. Check with your infrastructure planning team on integration with existing DCIM tools before commissioning.
Q: What is the maximum ambient temperature the ACCD76057 can operate in?
A: The ACCD76057 is rated for operation up to 120°F (49°C) ambient. This makes it suitable for outdoor rooftop installations and unconditioned mechanical rooms in hot climates that would exceed the limits of standard condensers.
Q: Does the ACCD76057 require 3-phase power, or can it run on single-phase supply?
A: The ACCD76057 requires 3-phase power at 208-230V, 60Hz. Single-phase supply is not compatible with this unit. Confirm your facility has appropriately sized 3-phase circuits and a dedicated disconnect before ordering.
Q: What is the cooling capacity of the ACCD76057?
A: The ACCD76057 delivers 101kW of cooling capacity, rated at a 95°F (35°C) standard ambient condition, with continued operation rated up to 120°F (49°C).
Q: How heavy is the ACCD76057, and what does that mean for installation planning?
A: The unit weighs 245.4 kg (541 lbs) unpackaged and 272.7 kg (601 lbs) in packaging. Structural load assessments for rooftop or raised-floor installations are mandatory. Coordinate with your mechanical engineer and facilities team before scheduling delivery or rigging.
Q: Is the ACCD76057 designed to work with APC's in-row cooling systems?
A: Yes. The ACCD76057 functions as the external condenser in APC's split cooling architecture, designed to pair with APC in-row coolers that route refrigerant to an outdoor or remote condenser for heat rejection. Verify compatibility with your specific in-row cooler model number before purchasing.

The ACCD76057 is one of the relatively few commercial condensers I've spec'd that carries a legitimate 120°F ambient rating — not a derated capacity number at that temperature, but a stated operational upper limit. For a client running a rooftop-mounted split cooling system in Phoenix or Houston, that distinction matters a lot when you're trying to maintain SLA uptime through a July heat event. At 101kW, this unit has the capacity to serve as the sole condenser for a mid-density data hall or to act as one node in a redundant N+1 cooling topology for larger deployments.
Technical Highlights:
Deployment Considerations:
The ACCD76057 is the right condenser for rooftop split-system installations at edge data centers, manufacturing facilities, or mid-sized colocation builds in regions where peak summer ambient temperatures regularly challenge standard condenser ratings — if that matches your site conditions, this is the unit to specify.