Panduit CBL CLT Polymer 1 Hole Config PK10
Glass-filled nylon, single-hole cable cleat designed to retain cables in place during low-to-intermediate short-circuit fault events
Manufacturer-verified compatible cameras, recorders, mounts, accessories, and licenses for this product. Adjust quantities and add the entire bundle to your cart in one click.
Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.
The Panduit CCPL1H3238-X is a single-hole, glass-filled nylon cable cleat designed for short-circuit fault retention on cable trays in low-to-intermediate fault-current environments. It clamps cables with an outside diameter of 32 to 38mm, installs directly onto a cable tray rung using a single user-supplied M10 bolt, and is tested to a peak fault current of 69.5kA in accordance with IEC 61914:2015. Each pack contains 10 cleats. The CCPL1H3238-X (often searched as CCPL1H3238 X) is Panduit's answer for industrial facilities, commercial MV/LV switchgear rooms, and data center power distribution runs where cable retention under fault conditions is a code-driven requirement — not an afterthought.
The CCPL1H3238-X installs on standard cable tray rungs using a single M10 bolt. It is compatible with cables in the 32–38mm outside diameter range and is not tied to a specific tray manufacturer — verify rung width accommodates the 70mm (2.75 in) overall width of the cleat body. Panduit's Panduit cable management line includes additional cleat sizes covering 10–57mm cable diameters across 10 cleat pieces per pack; if your installation involves multiple cable sizes, coordinate cleat selection across the full diameter range before procurement. This product is part of the broader cable management and protection category alongside cable tray systems, ladder rack, and associated hardware. For power distribution infrastructure planning, review our power distribution accessories section to coordinate cable routing hardware with busway and tray systems. Engineers specifying to IEC 61914:2015 should also consult a wire and cable management selection guide for spacing recommendations and fault-level coordination. Competitor part equivalents include 1BC3238, 1F-16, 382AA04, and 385AA07 for cross-reference purposes.
Q: What cable outside diameter range does the CCPL1H3238-X accept?
A: The CCPL1H3238-X is designed for cables with an outside diameter of 32 to 38mm. It does not adjust outside this range — measure your cable OD including the jacket before ordering.
Q: What peak fault current is the CCPL1H3238-X rated for?
A: The cleat has been tested to a peak fault current of 69.5kA per IEC 61914:2015 by a third-party laboratory. This makes it suitable for low-to-intermediate fault-level applications. Installations with fault levels exceeding this figure require a higher-rated cleat.
Q: What standard does the CCPL1H3238-X comply with?
A: The CCPL1H3238-X is tested and certified to IEC 61914:2015, the international standard governing cable cleats for electrical installations.
Q: What fastener is required to mount the CCPL1H3238-X?
A: A single M10 bolt, supplied by the installer. No additional brackets or clamp plates are required. The cleat mounts directly to a cable tray rung.
Q: What material is the CCPL1H3238-X made from?
A: Glass-filled nylon. The glass reinforcement improves rigidity and creep resistance compared to unfilled nylon, and the rounded edges protect cable insulation during installation and fault events.
Q: What is the operating temperature range of the CCPL1H3238-X?
A: -40°C to +60°C (-40°F to +140°F), suitable for unheated outdoor enclosures, cold-climate substations, and hot mechanical rooms.

The CCPL1H3238-X lands in a specific and well-defined niche: low-to-intermediate fault environments where you need IEC 61914:2015 compliance without the cost premium of stainless steel or aluminum cleats. The 69.5kA peak fault current test rating is the number I always ask engineers to verify against their arc flash and fault study before spec'ing this product — it's a hard ceiling, not a design margin.
Technical Highlights:
Deployment Considerations:
This cleat is the right call for commercial MV feeder runs in switchgear rooms, hospital power distribution infrastructure, and industrial plant cable trays where IEC 61914:2015 is called out in the project spec and fault levels sit below the 69.5kA threshold. If the fault study shows higher levels, or if the environment is corrosive enough to attack nylon, move to a metallic cleat family instead.