Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: CCAL2H8397-X
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 45% OFF

Panduit CCAL2H8397-X 131kA 2-Hole Aluminum Cable Cleat

Panduit CCAL2H8397-X Two-Hole Aluminum Cable Cleat for 83-97mm Cables The Panduit CCAL2H8397-X aluminum cable cleat secures single power cables 83-97m…

$765.34 $419.99 SAVE $345

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit CCAL2H8397-X 131kA 2-Hole Aluminum Cable Cleat

$765.34
$419.99

Overview

SKU: CCAL2H8397-X
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit CCAL2H8397-X Two-Hole Aluminum Cable Cleat for 83-97mm Cables

The Panduit CCAL2H8397-X aluminum cable cleat secures single power cables 83-97mm (3.27-3.82 inches) in diameter during short-circuit fault events up to 131kA peak current. IEC 61914:2015 certified, this two-hole clamp installs directly to cable tray rungs with user-supplied M10 bolts, meeting international standards for electrical installations in data centers, substations, industrial facilities, and commercial power distribution systems. Ships as a package of 10 cleats; insulating spacers and washers sold separately when galvanic corrosion protection is required.

Key Features

  • IEC 61914:2015 certified for international electrical code compliance
  • 131kA peak fault current rating retains cables during short-circuit events
  • Aluminum construction balances corrosion resistance with mechanical strength
  • Two-hole mounting pattern for direct attachment to cable tray rungs (M10 bolt holes)
  • Sized for single cables 83-97mm outer diameter (3.27-3.82 inches)
  • 115mm height × 162mm width footprint (4.53" × 6.37")
  • Natural aluminum finish for less corrosive environments
  • Package quantity: 10 cleats per box

Short-circuit faults generate electromagnetic forces that can eject unsecured cables from trays, causing secondary damage and extended outages. The CCAL2H8397-X clamp mechanically restrains the cable within the cleat body during fault events—tested and certified to IEC 61914:2015 at 131 kiloamps peak. The two-hole design mounts perpendicular to the cable tray rung using M10 bolts (not included), placing the cleat directly over the rung for maximum structural support. Aluminum construction provides sufficient strength for medium-to-high fault currents while resisting corrosion in indoor and sheltered outdoor environments; for highly corrosive locations or coastal installations, consider stainless steel alternatives. When installing, torque M10 fasteners per Panduit specifications and verify the cleat fully encircles the cable insulation—partial engagement reduces fault retention.

This cleat fits cable diameters from 83mm to 97mm, covering common medium-voltage and large low-voltage power cables used in 480V–15kV distribution systems, battery interconnects, generator feeders, and UPS output circuits. The 162mm width spans standard cable tray rung spacing; confirm your tray's rung width and bolt-hole pitch before ordering. Insulating spacers and non-conductive washers (sold separately) are required when installing aluminum cleats on steel trays or when securing aluminum-jacketed cables—direct metal-to-metal contact creates galvanic cells that accelerate corrosion. For mixed-material installations, consult Panduit's accessory catalog for the correct spacer kit matching your cable tray type. Each box contains 10 cleats; calculate quantity by counting vertical cable runs and applying cleats at every support point per NEC Article 300 and IEC 61914 spacing tables (typically every 0.5–1 meter depending on fault level).

IEC 61914:2015 certification requires third-party witnessed testing at the declared fault current; the 131kA rating on this cleat reflects actual laboratory short-circuit testing, not theoretical calculations. This certification is mandatory for installations in jurisdictions adopting IEC standards and is increasingly specified by engineers in North American projects requiring international compliance. The CCAL2H8397-X's combination of aluminum construction, direct-tray mounting, and 131kA rating makes it suitable for substations, switchgear rooms, critical power distribution in hospitals and data centers, and renewable energy interconnections where fault currents approach or exceed 100kA.

Specifications
Product Type: Cable Cleat
Clamp Type: Two-Hole
Material: Aluminum
Finish: Natural
Cable Diameter Min: 83mm (3.27 in)
Cable Diameter Max: 97mm (3.82 in)
Cable Configuration: Single Cable
Mounting Type: Direct to Cable Tray Rung
Mounting Hole Size: M10
Fault Current Rating: 131kA Peak
Standards Compliance: IEC 61914:2015
Overall Height: 115mm (4.53 in)
Overall Width: 162mm (6.37 in)
Package Quantity: 10
Insulating Spacers: Sold Separately
Environment: Medium to Low Corrosion
UPC: 61305674747
Manufacturer Part Number: CCAL2H8397-X
Type: Cable Cleat
Form Factor: Two-Hole Clamp
Durability: 131kA Fault Current Rated
Lens Focal Length: 83-97 mm
Height In: 4.53
Height Mm: 115
Width In: 6.37
Width Mm: 162
Carton Qty: 0
Package Qty: 10
Standards: IEC 61914:2015
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources