Panduit CCAL1H1619-X Aluminum Cable Cleat 16-19mm

Panduit CCAL1H1619-X One-Hole Aluminum Cable Cleat The Panduit CCAL1H1619-X delivers IEC 61914:2015-certified short circuit protection for single powe…

$490.87 $268.99 SAVE $222

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Panduit CCAL1H1619-X Aluminum Cable Cleat 16-19mm

$490.87
$268.99

Overview

SKU: CCAL1H1619-X
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Panduit CCAL1H1619-X One-Hole Aluminum Cable Cleat

The Panduit CCAL1H1619-X delivers IEC 61914:2015-certified short circuit protection for single power cables in datacenters, substations, and industrial facilities. Engineered for 16–19mm cable diameters, this one-hole aluminum cleat mounts directly to cable tray rungs and retains cables through fault events up to 93.4kA peak current—critical for preventing cascading damage in high-density power distribution runs. Commercial integrators spec these cleats to meet international electrical codes while maintaining fast installation cycles on vertical and horizontal cable tray systems.

Key Features

  • IEC 61914:2015 certified for compliance with international cable retention standards
  • 93.4kA peak fault current rating protects against high-energy short circuit events
  • One-hole aluminum construction balances corrosion resistance with reduced weight vs. steel cleats
  • Fits single cable diameters 16–19mm (0.63–0.75") for medium-voltage power runs
  • Direct mount to cable tray rung via M10 bolt (user-supplied) for tool-free tray integration
  • Natural aluminum finish resists oxidation in indoor industrial environments
  • 10-pack quantity streamlines multi-run installations and inventory management
  • Compatible with Panduit insulating spacers and washers to prevent galvanic corrosion

Cable cleats are mandatory under IEC 60364 and NEC Article 300 for cables subject to electromagnetic forces during short circuits. The CCAL1H1619-X's 93.4kA rating handles fault currents typical of 480V/600V commercial distribution systems, preventing cables from whipping free and contacting adjacent conductors or structural elements. The one-hole aluminum body measures 48mm wide by 29mm high, providing ample clamping surface for cables in the 16–19mm range while keeping tray-to-cleat installation height minimal—essential in shallow overhead cable tray or tight equipment room ceilings. Aluminum's lower conductivity vs. steel reduces induced heating during high-current events, and the natural finish maintains conductivity for bonding when specified. Each cleat ships with manufacturer lot traceability for compliance documentation.

Install these cleats on vertical risers in telecom hubs, horizontal cable tray above server rows, or outdoor-rated tray runs feeding remote equipment shelters. The M10 mounting hole aligns with standard cable tray rung spacing (150mm/6" or 300mm/12" centers), and the single-bolt attachment lets crews cleat entire runs faster than multi-fastener designs. Pair with Panduit's insulating spacers when clamping aluminum-jacketed cable to prevent galvanic cell formation between dissimilar metals, or when tray grounding creates ground-loop concerns. The 10-pack packaging matches typical bay-length cable runs (8–12 cleats per 20-foot tray section at code-minimum spacing), reducing reorder cycles on multi-rack datacenter builds.

Competitive with Ellis Patents 1A-12N and Oglaend 370BA03 aluminum cleats but certified to the stricter 2015 revision of IEC 61914, which requires dynamic testing at higher fault durations. Panduit's aluminum alloy formulation balances tensile strength with ductility to absorb fault-induced cable movement without cracking—a failure mode seen in harder alloys under repeated seismic or thermal cycling. This cleat is the correct choice for medium-duty power distribution where steel's higher mass isn't required and where corrosion exposure remains low to moderate.

Specifications
Product Type: Cable Cleat
MPN: CCAL1H1619-X
Clamp Type: One-Hole (1H)
Material: Aluminum
Color: Natural
Cable Diameter Range: 16–19mm (0.63–0.75")
Cable Configuration: Single Cable
Peak Fault Current Rating: 93.4kA
Standards Compliance: IEC 61914:2015
Mounting Method: Direct to cable tray rung via M10 bolt (user-supplied)
Overall Width: 48mm (1.88")
Overall Height: 29mm (1.14")
Package Quantity: 10 pieces
Insulating Accessories: Sold separately (spacers and washers for galvanic corrosion protection)
Competitive Cross-Reference: Ellis 1BC1619A, 1A-12N; Oglaend 370BA03
Application Environment: Indoor/outdoor, low to medium corrosive environments
UPC: 061305673744
Type: Cable Cleat
Durability: Aluminum
Lens Focal Length: 16-19 mm
Height In: 1.14
Height Mm: 29
Width In: 1.88
Width Mm: 48
Carton Qty: 0
Package Qty: 10
Standards: IEC 61914:2015
Upc: 61305673744
Cable Category: wire-routing-management-protection
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources