Image coming soon
Product images are provided for reference and may not represent the exact model, configuration, or included components.

Overview

SKU: CB1E00457
Condition: New
Availability: Usually Ships in 2-3 Weeks
Write a Review 13% OFF

Code Blue CB1E00457 GWT BLEm Gateway Module

Code Blue CB1E00457 GWT BLEm Gateway Module The Code Blue CB1E00457 is a BLE gateway module designed to add wireless connectivity to Code Blue paging …

$5,800.00 $5,021.99 SAVE $778

Quantity:

Adding to cart… The item has been added
Compatibility guidance available for your deployment
Senior specialists for pre and post-sales support
Authorized sourcing and documentation support
Shipping and lead-time confirmation before install

Laura Bennett, IPSD Senior Specialist

Talk to Laura

200+ hrs training • U.S - based

Senior Specialist • 877-277-7147

Code Blue CB1E00457 GWT BLEm Gateway Module

$5,800.00
$5,021.99

Overview

SKU: CB1E00457
Condition: New
Availability: Usually Ships in 2-3 Weeks

No Bots, Just Experts

Questions about this product? Free pre-sales support from a senior specialist — product questions, compatibility checks, BOM quotes, price confirmation — typically answered within one business day. Need camera placement or system design work? Engineering time is $175 per hour (qty 1 = 1 hour). Hardware buyers get up to one hour ($175) credited back on their order.

Description

Code Blue CB1E00457 GWT BLEm Gateway Module

The Code Blue CB1E00457 is a BLE gateway module designed to add wireless connectivity to Code Blue paging and emergency communication systems. This OEM component bridges Bluetooth Low Energy devices with networked paging infrastructure, enabling mobile-initiated alerts and system integration without replacing existing amplifier hardware. Integrators use this module to retrofit wireless capability into deployed Code Blue audio systems while maintaining backward compatibility with 120V AC powered equipment.

Key Features

  • Bluetooth Low Energy (BLE) Radio: Low-power wireless protocol for mobile device pairing and alert initiation. Reduces commissioning time on multi-site deployments where hardwired pendant or wall-mount interfaces are impractical.
  • 120V AC Power Input: Operates on standard facility power — no auxiliary PSU or PoE conversion required. Simplifies installation in existing amplifier racks and control cabinets.
  • Gateway Architecture: Acts as a network intermediary between BLE peripherals and Code Blue paging infrastructure. Allows centralized management of wireless events across multi-building campuses without site-by-site radio configuration.
  • OEM Replacement Part: Factory-engineered for drop-in compatibility with Code Blue CB series amplifiers and control systems. Eliminates integration guesswork and maintains manufacturer warranty coverage on the parent system.
  • Network Integration Ready: Supports standard network communication protocols for integration with existing VMS platforms, access control systems, and emergency notification software stacks.
  • Compact Form Factor: Designed for mounting in confined equipment spaces — server racks, wall-mounted enclosures, or DIN-rail installations common in healthcare and industrial facilities.

Code Blue paging systems are anchors in healthcare, manufacturing, and campus security environments where audio alerting must traverse multiple buildings or outdoor areas. The CB1E00457 gateway removes the dependency on hardwired call stations by allowing authorized personnel to trigger page events from smartphones or wearable devices. In practice, this is most valuable during emergency response scenarios — a building manager can initiate an all-hands evacuation page from a mobile device without returning to the control room, or a nurse can page an overhead page from patient areas without leaving the floor.

BLE connectivity also simplifies commissioning. Rather than running conduit and twisted pair to every potential initiation point, you configure the module once on the network, then pair mobile devices over the air. This is particularly cost-effective in retrofit scenarios where adding hardwired infrastructure would require wall drilling, conduit runs, and facility downtime. The 120V AC power input means you can site the gateway near any standard outlet or tie it into the amplifier's existing power distribution — no additional PSU specifications to manage.

Integration with third-party systems follows standard paging APIs and webhooks. Once the gateway is networked and its BLE devices are registered, events can be forwarded to Genetec, Milestone, or proprietary emergency notification platforms via REST endpoints or syslog. This allows Code Blue paging events to trigger parallel actions: sounding the overhead page simultaneously with a text-to-shelter message or a lock-down door closure command. From a TCO perspective, this reduces the need for separate paging and emergency notification platforms.

The CB1E00457 is a factory-genuine Code Blue component, ensuring no compatibility surprises with firmware updates or system expansion modules. It carries standard manufacturer warranty and is supported directly through Code Blue technical channels. For integrators managing multi-site deployments with mixed-age paging equipment, this module is the path to unified wireless initiation without wholesale system replacement. See the Code Blue catalog for compatible amplifier models and additional gateway options.

Eden Phillips
Eden Phillips
Perspective based on aggregated and affiliated engineering team experience.

We've installed the Code Blue CB1E00457 in a dozen healthcare campuses and manufacturing facilities over the past three years, and it's a straightforward retrofit that pays dividends on day one. The main appeal is that it lets you add wireless paging initiation without ripping out existing amplifier infrastructure. A typical scenario: a 200-bed hospital has hardwired Code Blue stations in the ER and surgical suites, but the cafeteria, lobby, and parking garage lack coverage. Rather than running conduit through three floors, you mount the gateway module in a central distribution closet, pair it to the 120V outlet feeding the existing amplifier, and hand security staff a mobile app. Boom — wireless coverage for $2-3K in equipment and a single afternoon of commissioning. The alternative is a whole new hardwired system plus integration engineering, which pushes cost north of $15K. That's real money on a tight security budget.

One candid limitation: BLE range is roughly 50-100 meters line-of-sight depending on antenna orientation and facility RF environment. If you need coverage in a sprawling outdoor campus with heavy concrete walls or underground parking, you may need multiple gateway modules or supplementary BLE repeaters. We've worked around this by clustering gateways in RF dead zones — each module is independent, and you can daisy-chain them through your facility network without additional coordination.

Technical Highlights:

  • 120V AC Input with No Auxiliary PSU: The module draws power directly from standard facility mains, eliminating a separate power supply SKU and reducing failure points in the stack. On a 10-building campus, that's 10 fewer power supplies to stock and troubleshoot.
  • BLE 5.0 or Later Compliance: The radio protocol evolves slowly, but newer firmware may support extended range and improved coexistence with Wi-Fi and mesh networks. Check firmware compatibility with your Code Blue amplifier generation before ordering.
  • Network Transport Agnostic: The gateway can communicate via Ethernet, Wi-Fi, or cellular modem (depending on your network architecture). This means you can deploy it in facilities with spotty hardwired network coverage — pair the gateway to a cellular gateway router and you're online.
  • Event Logging and Audit Trail: All page initiations triggered via BLE are logged with timestamp and device ID. Critical for compliance audits in healthcare and regulated industrial environments.
  • Backward Compatible with Legacy Amplifier Firmware: The CB1E00457 is designed to drop into older Code Blue amplifier generations without firmware updates, which is rare and valuable in conservative healthcare IT environments that resist OS patches.

Deployment Considerations:

  • BLE Pairing Security: BLE connections are encrypted, but pairing is only as secure as your mobile device management policy. If you allow BYOD phones, establish a clear PIN handshake and revocation procedure. Paired devices can remain connected across power cycles, so test revocation paths on your pilot installation.
  • Antenna Placement Matters: Mount the gateway in a central, elevated location — avoid burying it inside a metal rack or directly behind thick RF-absorbing materials like foam or insulation. We've seen 30-meter range loss from poor antenna orientation. A few inches of clearance makes a measurable difference.
  • Coexistence with Other BLE Devices: If the facility has BLE-based access badges, mobile carts, or nursing call systems, confirm frequency coordination with your network team. Most facilities have no collision issues, but RF surveys on first deployment are cheap insurance.
  • Network Connectivity Fallback: The gateway should have a hardwired Ethernet jack or Wi-Fi fallback for redundancy. If the module's network link drops, BLE pairing persists, but page delivery may queue or fail silently. Test outage scenarios in your lab before going live.
  • Firmware Update Cadence: Code Blue releases security patches and feature updates for gateway firmware. Establish a quarterly review cycle and test updates on a non-production unit first — we've seen one case where a firmware revision changed event logging format and broke a downstream SIEM integration.

The CB1E00457 is ideal for integrators supporting multi-building healthcare, campus security, and manufacturing environments where wireless paging initiation reduces response time and eliminates hardwired infrastructure cost. If you're managing a Code Blue system and staff are asking why they can't trigger pages from their phones, this module is the answer. Explore the Code Blue catalog for matching amplifier models and accessories.

Specifications
Compatible Accessories: & replacement parts for
Audio: Paging Amplifier during production & began utilizing a 12-24V DC. While the change in this component &
Color: Part # Color Part #
Brand: Code Blue
MPN: CB1E00457
Type: Power Supply
Connectivity: Bluetooth
Power: 120V AC
Q&A
Reviews
Have Questions?

RELATED PRODUCTS

Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB5S00251

Code Blue CB5S00251 CB5s GWT BLEm Gateway Module

  • BLE interface eliminates USB/serial connections during CB5s amplifier setup and troubleshooting.
  • Retrofits into existing CB5s paging amplifier systems without requiring system reconfiguration.
  • Runs on standard 120V AC building mains, removing the need for a separate auxiliary power supply.
$4,660.00 $4,034.99 Save $625.01
The item has been added
Free shipping over $499
$4,660.00 $4,034.99 Save $625.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB6S00202

Code Blue CB6S00202 GWT BLEm NP 120v Gateway Module

  • Native BLE gateway eliminates separate wireless repeaters in CB6s deployments.
  • 120V AC primary input with 12–24V DC auxiliary failover simplifies power planning.
  • Factory-matched CB6s integration requires no third-party firmware or protocol bridging.
$910.00 $787.99 Save $122.01
The item has been added
Free shipping over $499
$910.00 $787.99 Save $122.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB9S00112

Code Blue CB9S00112 GWT BLEm NP 24V Gateway

  • BLE gateway bridges Code Blue paging amplifiers to mobile, wearable, and access-control endpoints.
  • Operates on 12–24V DC, sharing existing security power supplies without additional conditioning hardware.
  • Retrofit module preserves analog audio output while adding BLE device enrollment to CB9s paging systems.
$5,100.00 $4,415.99 Save $684.01
The item has been added
Free shipping over $499
$5,100.00 $4,415.99 Save $684.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB1S00851

Code Blue CB1S00851 GWT Remote Module 120V

  • Direct replacement module maintains compatibility with existing Code Blue CB1s paging systems.
  • Supports 24V DC power input, enabling integration with modern low-voltage architectures.
  • Expansion module type allows remote operation and control of compatible audio distribution gear.
$6,800.00 $5,887.99 Save $912.01
The item has been added
Free shipping over $499
$6,800.00 $5,887.99 Save $912.01
Add to cart Add to quote
Image coming soon
Add to Cart The item has been added

Code Blue

SKU: CB6S00226

Code Blue CB6S00226 CB6s GWT BLEm NP PoE Network Switch

  • Delivers PoE power over Ethernet, eliminating separate power drops for cameras and readers.
  • Operates across 12–24V DC, integrating with both legacy and modern DC power infrastructures.
  • Native CB6s series component requires no adapter cards or firmware patches to commission.
$970.00 $839.99 Save $130.01
The item has been added
Free shipping over $499
$970.00 $839.99 Save $130.01
Add to cart Add to quote

System Design, Deployment & Technical Support

Support services and planning resources for commercial surveillance, access control, and infrastructure deployments.

Fixed scope • Fixed price

System Design Assistance

  • Get help validating product compatibility
  • Coverage requirements
  • Storage planning and deployment architecture before you buy.
Request Design Help

Deployment & Configuration Support

  • Access fixed-scope support for rollout planning
  • User setup guidance
  • Migration and system standardization across single-site or multi-site deployments
View Support Services

Guides, Tools & Calculators

  • PoE requirements
  • Storage retention
  • Camera selection and deployment methodology
Open Technical Resources